G700-MG-MIB :: cmgTimeslotLowerThreshold

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › G700-MG-MIB › cmgTimeslotLowerThreshold

cmgTimeslotLowerThreshold

Module: G700-MG-MIB

OID (symbolic): G700-MG-MIB::cmgTimeslotLowerThreshold

OID (numeric): 1.3.6.1.4.1.6889.2.9.1.1.16

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Timeslot Lower threshold. After the gateway has sent a cmgTimeslotOccupancyFault trap, it will send a cmgTimeslotOccupancyClear as soon as the timeslot usage goes below this threshold. Also after the gateway has sent a cmgTimeslotAvailabilityFault trap, it will send cmgTimeslotAvailabilityClear as soon as the timeslot usage goes below this threshold. This lower threshold must be less than the upper threshold; for example cmgTimeslotLowerThreshold=85, cmgTimeslotUpperThreshold=90. Default is 85. cmgTimeslotMonitoring must be set to on(1) for traps to be sent.

What is cmgTimeslotLowerThreshold?

The percentage of timeslot occupancy below which the switch sends a clear trap after a fault was previously raised; must be set lower than cmgTimeslotUpperThreshold (e.g. lower=85, upper=90). Default is 85, and requires cmgTimeslotMonitoring to be on.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6889.2.9.1.1.16
snmpwalk -v2c -c public <target> G700-MG-MIB::cmgTimeslotLowerThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6889.2.9.1.1.16.1
snmpget -v2c -c public <target> G700-MG-MIB::cmgTimeslotLowerThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.6889.2.9.1.1.16.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> cmgTimeslotLowerThreshold.1

Start monitoring Avaya G700/G450/G350 H.248 Media Gateway with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the G700-MG-MIB::cmgTimeslotLowerThreshold OID value, configure state conditions and alerts, and monitor any Avaya G700/G450/G350 H.248 Media Gateway from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.6889avayaAV-APPLICATION-ENABLEMENT-SERVICES-MIB
1.3.6.1.4.1.6889.2mibsAV-APPLICATION-ENABLEMENT-SERVICES-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6889.2.9g700MediaGatewayMIBG700-MG-MIB
1.3.6.1.4.1.6889.2.9.1cmgmibG700-MG-MIB
1.3.6.1.4.1.6889.2.9.1.1cmgChassisG700-MG-MIB
1.3.6.1.4.1.6889.2.9.1.1.16cmgTimeslotLowerThresholdG700-MG-MIB