All MIBs › FRX-MIB › nodeAlarmedPorts
nodeAlarmedPorts
Module: FRX-MIB
OID (symbolic): FRX-MIB::nodeAlarmedPorts
OID (numeric): 1.3.6.1.4.1.177.3.2.23
Node type: OBJECT-TYPE
Type: Gauge
Access: read-only
Description: The number of front or backcard ports on this node where any of the following conditions is true: - portTBusState (or T1 Status for backcard ports) is 'down' - portUNIState is 'down' - portAlarmedPVCs is not zero.
What is nodeAlarmedPorts?
Counts how many front- or back-card ports currently have an active alarm condition -- TBus (or T1 status) down, UNI state down, or at least one alarmed PVC -- giving an admin a single number to poll as a first-pass health check before drilling into individual ports.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.177.3.2.23 snmpwalk -v2c -c public <target> FRX-MIB::nodeAlarmedPorts
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.177.3.2.23.1 snmpget -v2c -c public <target> FRX-MIB::nodeAlarmedPorts.1
Start monitoring Legacy frame relay switch/access node (Netrix/FastComm-style FRX platform) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRX-MIB::nodeAlarmedPorts OID value, configure state conditions and alerts, and monitor any Legacy frame relay switch/access node (Netrix/FastComm-style FRX platform) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.177 | net | FRX-MIB |
| 1.3.6.1.4.1.177.3 | frx | FRX-MIB |
| 1.3.6.1.4.1.177.3.2 | node | FRX-MIB |
| 1.3.6.1.4.1.177.3.2.23 | nodeAlarmedPorts | FRX-MIB |