FRSLD-MIB :: frsldPvcDataMissedPolls

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFRSLD-MIBfrsldPvcDataMissedPolls

frsldPvcDataMissedPolls

Module: FRSLD-MIB

OID (symbolic): FRSLD-MIB::frsldPvcDataMissedPolls

OID (numeric): 1.3.6.1.2.1.95.1.3.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total number of polls that have been determined to be missed. These polls are typically associated with the calculation of delay but may also be used for the calculation of other statistics. If an anticipated poll is not received in a reasonable amount of time, it should be counted as missed. The value used to determine the reasonable amount of time is contained in frsldPvcCtrlDelayTimeOut.

Discontinuities in the value of this counter can occur at re-initialization of the management system and at other times as indicated by

frsldPvcCtrlLastPurgeTime.

What is frsldPvcDataMissedPolls?

A running counter of delay-measurement polls for this PVC that were determined to be missed, based on the timeout configured in frsldPvcCtrlDelayTimeOut. A steadily climbing value points to intermittent packet loss or high jitter on the path being measured, and it can reset at a discontinuity marked by frsldPvcCtrlLastPurgeTime.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.95.1.3.1.1
snmpwalk -v2c -c public <target> FRSLD-MIB::frsldPvcDataMissedPolls

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.95.1.3.1.1.1
snmpget -v2c -c public <target> FRSLD-MIB::frsldPvcDataMissedPolls.1

Start monitoring Vendor-neutral Frame Relay network equipment/carrier circuit, any manufacturer (FRF.13 service levels) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRSLD-MIB::frsldPvcDataMissedPolls OID value, configure state conditions and alerts, and monitor any Vendor-neutral Frame Relay network equipment/carrier circuit, any manufacturer (FRF.13 service levels) from a single console.

How to Use in IPNetwork Monitor

Select a device implementing FRSLD-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type frsldPvcDataMissedPolls into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total number of polls that have been determined to be missed. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.95frsldMIBFRSLD-MIB
1.3.6.1.2.1.95.1frsldObjectsFRSLD-MIB
1.3.6.1.2.1.95.1.3frsldPvcDataTableFRSLD-MIB
1.3.6.1.2.1.95.1.3.1frsldPvcDataEntryFRSLD-MIB
1.3.6.1.2.1.95.1.3.1.1frsldPvcDataMissedPollsFRSLD-MIB