All MIBs › FRSLD-MIB › frsldPvcCtrlLastPurgeTime
frsldPvcCtrlLastPurgeTime
Module: FRSLD-MIB
OID (symbolic): FRSLD-MIB::frsldPvcCtrlLastPurgeTime
OID (numeric): 1.3.6.1.2.1.95.1.1.1.11
Node type: OBJECT-TYPE
Type: TimeStamp
Access: read-only
Description: This object returns the value of sysUpTime at the time the information was last purged. This value SHOULD be set to the sysUpTime upon setting frsldPvcCtrlStatus to active(1) for the first time. Each time a discontinuity in the counters occurs, this value MUST be set to the sysUpTime.
If frsldPvcCtrlStatus has never been active(1), this object SHOULD return 0.
This object SHOULD be used as the discontinuity timer for the counters in frsldPvcDataTable.
What is frsldPvcCtrlLastPurgeTime?
The value of sysUpTime recorded the last time this PVC's statistics were purged; it's set on first transition to active(1) and again on any counter discontinuity, and reads as 0 if the row has never been active. Use this as the discontinuity reference point when interpreting counters in the PVC data table, since a jump in this value means the counters reset.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.95.1.1.1.11 snmpwalk -v2c -c public <target> FRSLD-MIB::frsldPvcCtrlLastPurgeTime
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.95.1.1.1.11.1 snmpget -v2c -c public <target> FRSLD-MIB::frsldPvcCtrlLastPurgeTime.1
Start monitoring Vendor-neutral Frame Relay network equipment/carrier circuit, any manufacturer (FRF.13 service levels) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRSLD-MIB::frsldPvcCtrlLastPurgeTime OID value, configure state conditions and alerts, and monitor any Vendor-neutral Frame Relay network equipment/carrier circuit, any manufacturer (FRF.13 service levels) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | AXON-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.95 | frsldMIB | FRSLD-MIB |
| 1.3.6.1.2.1.95.1 | frsldObjects | FRSLD-MIB |
| 1.3.6.1.2.1.95.1.1 | frsldPvcCtrlTable | FRSLD-MIB |
| 1.3.6.1.2.1.95.1.1.1 | frsldPvcCtrlEntry | FRSLD-MIB |
| 1.3.6.1.2.1.95.1.1.1.11 | frsldPvcCtrlLastPurgeTime | FRSLD-MIB |