FRSLD-MIB :: frsldPvcCtrlLastPurgeTime

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsFRSLD-MIBfrsldPvcCtrlLastPurgeTime

frsldPvcCtrlLastPurgeTime

Module: FRSLD-MIB

OID (symbolic): FRSLD-MIB::frsldPvcCtrlLastPurgeTime

OID (numeric): 1.3.6.1.2.1.95.1.1.1.11

Node type: OBJECT-TYPE

Type: TimeStamp

Access: read-only

Description: This object returns the value of sysUpTime at the time the information was last purged. This value SHOULD be set to the sysUpTime upon setting frsldPvcCtrlStatus to active(1) for the first time. Each time a discontinuity in the counters occurs, this value MUST be set to the sysUpTime.

If frsldPvcCtrlStatus has never been active(1), this object SHOULD return 0.

This object SHOULD be used as the discontinuity timer for the counters in frsldPvcDataTable.

What is frsldPvcCtrlLastPurgeTime?

The value of sysUpTime recorded the last time this PVC's statistics were purged; it's set on first transition to active(1) and again on any counter discontinuity, and reads as 0 if the row has never been active. Use this as the discontinuity reference point when interpreting counters in the PVC data table, since a jump in this value means the counters reset.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.95.1.1.1.11
snmpwalk -v2c -c public <target> FRSLD-MIB::frsldPvcCtrlLastPurgeTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.95.1.1.1.11.1
snmpget -v2c -c public <target> FRSLD-MIB::frsldPvcCtrlLastPurgeTime.1

Start monitoring Vendor-neutral Frame Relay network equipment/carrier circuit, any manufacturer (FRF.13 service levels) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRSLD-MIB::frsldPvcCtrlLastPurgeTime OID value, configure state conditions and alerts, and monitor any Vendor-neutral Frame Relay network equipment/carrier circuit, any manufacturer (FRF.13 service levels) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
Numeric OIDNameModule
1.3.6.1.2.1.95frsldMIBFRSLD-MIB
1.3.6.1.2.1.95.1frsldObjectsFRSLD-MIB
1.3.6.1.2.1.95.1.1frsldPvcCtrlTableFRSLD-MIB
1.3.6.1.2.1.95.1.1.1frsldPvcCtrlEntryFRSLD-MIB