FRI-OPT-MIB :: friSCfgX25Options

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FRI-OPT-MIB › friSCfgX25Options

friSCfgX25Options

Module: FRI-OPT-MIB

OID (symbolic): FRI-OPT-MIB::friSCfgX25Options

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.3.9.1.28

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another vanguard device INL may be a poor choice for high speed links. INLB is set with INL to improve performance of high speed links. INLB - set with INL options to improve performance if inter-node link is a high speed link. DELAY - Enable Delay and Path Trace on this link Any combination of above specified by summing (e.g. CUG+ CAUSE+....).

What is friSCfgX25Options?

Text list (up to 24 characters) of X.25 options on this station, combined with plus signs such as CUG+CAUSE: CUG checks closed user groups, CAUSE passes cause/diagnostic codes in outbound packets, HOLD keeps calls across a link restart, INL marks an inter-node link to another Vanguard device (INLB improves INL on high-speed links), DELAY enables delay and path trace, NONE means no option.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.9.1.28
snmpwalk -v2c -c public <target> FRI-OPT-MIB::friSCfgX25Options

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.9.1.28.1
snmpget -v2c -c public <target> FRI-OPT-MIB::friSCfgX25Options.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.3.9.1.28.1 s <value>

Start monitoring Codex CDX-6500 Frame Relay interface/WAN access device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRI-OPT-MIB::friSCfgX25Options OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay interface/WAN access device from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3cdx6500PCTStationProtocolGroupATM-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.3.9cdx6500SPCTFRIStationTableFRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.9.1cdx6500SPCTFRIStationEntryFRI-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.9.1.28friSCfgX25OptionsFRI-OPT-MIB