-- Version 2.15.1.2, Modified: 2001-10-20 11:28:21-04 FRI-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS Counter, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500PCTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 3 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having SIZE (0..255) -- The FRI Port Configuration Table -- This Table replaces cdx6500PCTFRDTEPortTable which is now obsolete cdx6500PPCTFRIPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPCTFRIPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains Frame Relay DTE Port configuration parameters." ::= { cdx6500PCTPortProtocolGroup 31 } cdx6500PPCTFRIPortEntry OBJECT-TYPE SYNTAX Cdx6500PPCTFRIPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Port Configuration Table." INDEX { friPCfgPortNumber } ::= { cdx6500PPCTFRIPortTable 1 } -- NOTE : Numeric objects which are skipped during configuration -- will return 0 on query. Cdx6500PPCTFRIPortEntry ::= SEQUENCE { friPCfgPortNumber INTEGER, friPCfgPortType INTEGER, friPCfgConnectionType INTEGER, friPCfgClockSource INTEGER, friPCfgClockSpeed INTEGER, friPCfgHighestStnNumber INTEGER, friPCfgFrameSeqCounting INTEGER, friPCfgPktSeqCounting INTEGER, friPCfgCntrlProtocolSupport INTEGER, friPCfgHighPriorityStn INTEGER, friPCfgMaxVoiceBWBitsPerSec INTEGER, friPCfgSegSizeVoicePresent INTEGER, friPCfgSegSizeVoiceNotPresent INTEGER, friPCfgT391Timer INTEGER, friPCfgT392Timer INTEGER, friPCfgN391PollCycle INTEGER, friPCfgN392ErrsDuringMonitoredEvents INTEGER, friPCfgN393MonitoredEvents INTEGER, friPCfgNT1PollTimer INTEGER, friPCfgNT2VerificationTimer INTEGER, friPCfgNN1StatusPollingCycle INTEGER, friPCfgNN2ErrsDuringMonitoredEvents INTEGER, friPCfgNN3MonitoredEvents INTEGER, friPCfgInvertTXClock INTEGER, friPCfgControlProtocolOptions DisplayString, friPCfgDiscardControlOptions INTEGER, friPCfgStartSvcDlci INTEGER, friPCfgSubscriberNumber OCTET STRING, friPCfgMaxFmif INTEGER, friPCfgT200 INTEGER, friPCfgN200 INTEGER, friPCfgWindowK INTEGER, friPCfgT203 INTEGER, friPCfgT303 INTEGER, friPCfgT305 INTEGER, friPCfgT308 INTEGER, friPCfgT310 INTEGER, friPCfgControlProtocol INTEGER, friPCfguniState INTEGER, friPCfguniSSVP INTEGER, friPCfguniSSVNP INTEGER, friPCfguniSegDelay INTEGER, friPCfguniCheckPckSize INTEGER, friPCfgElectricalInterfaceType INTEGER, friPCfgV24ElectricalInterfaceOption INTEGER, friPCfgHighSpeedElectricalInterfaceOption INTEGER } friPCfgPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Port number of this port." ::= { cdx6500PPCTFRIPortEntry 1 } friPCfgPortType OBJECT-TYPE SYNTAX INTEGER { fri(18) } ACCESS read-only STATUS mandatory DESCRIPTION "Port type of the Port." -- DEFVAL { fri } ::= { cdx6500PPCTFRIPortEntry 2 } friPCfgConnectionType OBJECT-TYPE SYNTAX INTEGER { simp (1), dtr (2), simpb (21), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "The Specified control signal handshake and clocking required for a connection to be made to this port : simp - simple, no control signals required. dtr - dedicated, require the data terminal ready signal (DTR). simpb - simple, no control signals required for data transmission and reception. By default output leads will be low. nc - Skipped during configuration." -- DEFVAL { simp } ::= { cdx6500PPCTFRIPortEntry 3 } friPCfgClockSource OBJECT-TYPE SYNTAX INTEGER { int (1), ext (2), extint (3), extlp (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "int - Internal clock source ext - External clock source. extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. nc - Skipped during configuration." -- DEFVAL { ext } ::= { cdx6500PPCTFRIPortEntry 4 } friPCfgClockSpeed OBJECT-TYPE SYNTAX INTEGER (1200..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependent on the card type, and on the interface type." -- DEFVAL { 64000 } ::= { cdx6500PPCTFRIPortEntry 5 } friPCfgHighestStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS deprecated DESCRIPTION "This is the highest station number that can be configured on the FRI port. It is used to limit the configuration of stations." ::= { cdx6500PPCTFRIPortEntry 6 } friPCfgFrameSeqCounting OBJECT-TYPE SYNTAX INTEGER { normal (1), extended (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Port uses normal or extended frame sequence numbering: normal - normal sequencing (modulo 8) extended - extended sequencing (modulo 128). nc - Skipped during configuration. All stations on this port will be set to this value." -- DEFVAL { normal } ::= { cdx6500PPCTFRIPortEntry 7 } friPCfgPktSeqCounting OBJECT-TYPE SYNTAX INTEGER { normal (1), extended (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Port uses normal or extended packet level sequence numbers normal - normal sequencing (modulo 8) extended - extended sequencing (modulo 128) nc - Skipped during configuration. This parameter must be set to the same value at both this FRI port and the remote FRI port. All stations on this port will be set to this value." -- DEFVAL { normal } ::= { cdx6500PPCTFRIPortEntry 8 } friPCfgCntrlProtocolSupport OBJECT-TYPE SYNTAX INTEGER { annexD (1), none (2), lmi (3), annexA (4), auto (5), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Whether ANSI T1.617 Annex D, CCITT Q.933 Annex A or LMI Support is enabled. annexD - Annex D is enabled. none - None is enabled. lmi - LMI is enabled. annexA - Annex A is enabled. auto - Auto-learn the Network control protocol type nc - Skipped during configuration." -- DEFVAL { auto } ::= { cdx6500PPCTFRIPortEntry 9 } friPCfgHighPriorityStn OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this DLCI inactive, an alternate connection over a backup link is attempted." ::= { cdx6500PPCTFRIPortEntry 10 } friPCfgMaxVoiceBWBitsPerSec OBJECT-TYPE SYNTAX INTEGER (0..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter limits the bandwidth, in bits per sec (including overhead), for voice traffic passing through this frame relay port. A zero value disables any voice passing through this port." -- DEFVAL { 2048000 } ::= { cdx6500PPCTFRIPortEntry 11 } friPCfgSegSizeVoicePresent OBJECT-TYPE SYNTAX INTEGER { segSize32 (33), segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Data packets to be segmented into this maximum frame size when voice is active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments nc - Skipped during configuration." -- DEFVAL { segSize64 } ::= { cdx6500PPCTFRIPortEntry 12 } friPCfgSegSizeVoiceNotPresent OBJECT-TYPE SYNTAX INTEGER { segSize32 (33), segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025), segSize2048 (2049), segSize4096 (4097), disable (32000), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Data packets to be segmented into this maximum frame size when voice is not active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments segSize2048 - 2048 byte segments segSize4096 - 4096 byte segments disable - segment size is 32768 bytes nc - Skipped during configuration." -- DEFVAL { disable } ::= { cdx6500PPCTFRIPortEntry 13 } friPCfgT391Timer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds." -- DEFVAL { 10 } ::= { cdx6500PPCTFRIPortEntry 14 } friPCfgT392Timer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode." -- DEFVAL { 15 } ::= { cdx6500PPCTFRIPortEntry 15 } friPCfgN391PollCycle OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls." -- DEFVAL { 5 } ::= { cdx6500PPCTFRIPortEntry 16 } friPCfgN392ErrsDuringMonitoredEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3." -- DEFVAL { 5 } ::= { cdx6500PPCTFRIPortEntry 17 } friPCfgN393MonitoredEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3." -- DEFVAL { 4 } ::= { cdx6500PPCTFRIPortEntry 18 } friPCfgNT1PollTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds." -- DEFVAL { 10 } ::= { cdx6500PPCTFRIPortEntry 19 } friPCfgNT2VerificationTimer OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode." -- DEFVAL { 15 } ::= { cdx6500PPCTFRIPortEntry 20 } friPCfgNN1StatusPollingCycle OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls." -- DEFVAL { 5 } ::= { cdx6500PPCTFRIPortEntry 21 } friPCfgNN2ErrsDuringMonitoredEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3." -- DEFVAL { 3 } ::= { cdx6500PPCTFRIPortEntry 22 } friPCfgNN3MonitoredEvents OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3." -- DEFVAL { 4 } ::= { cdx6500PPCTFRIPortEntry 23 } friPCfgInvertTXClock OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert." -- DEFVAL { no } ::= { cdx6500PPCTFRIPortEntry 24 } friPCfgControlProtocolOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(0..24)) ACCESS read-write STATUS mandatory DESCRIPTION "These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async) dte-only - This forces a DTE Interface Type to remain as DTE, suppressing changes to BI-DIR using Annex A or D" ::= { cdx6500PPCTFRIPortEntry 25 } friPCfgDiscardControlOptions OBJECT-TYPE SYNTAX INTEGER { none (1), debit (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames" -- DEFVAL { none } ::= { cdx6500PPCTFRIPortEntry 26 } friPCfgStartSvcDlci OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The configured number is the lowest value DLCI the FRI port will allow for use of FR SVCs. A value of 0 means SVC procedures are not operating on this port and the signalling channel will not be active." ::= { cdx6500PPCTFRIPortEntry 27 } friPCfgSubscriberNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..19)) ACCESS read-write STATUS mandatory DESCRIPTION "All stations on this port use this value for their calling address information element. The valid format of this entry is: xx...xx000101 or xx...xx000103 Where: xx...xx00 represents the address of the station in IA5/ASCII coded hex terminated with a NUL character suffix. For example, an address of 123 would be represented by the string 31323300. 0101 is the suffix used to specify E.164 Number Plan 0103 is the suffix used to specify X.121 Number Plan To send a call without the Subscriber Number IE, set the address string to NUL only." ::= { cdx6500PPCTFRIPortEntry 28 } friPCfgMaxFmif OBJECT-TYPE SYNTAX INTEGER (262..4096) ACCESS read-write STATUS mandatory DESCRIPTION "This is the value used for link layer core parameters information element negotiation of maximum frame mode information field (FRIF) size in bytes. The value applies to both inbound and outbound frames. The value is specified in outgoing SETUP messages and is the maximum accepted value on incoming SETUP messages." ::= { cdx6500PPCTFRIPortEntry 29 } friPCfgT200 OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the value in tenths of seconds (1/10 s) of the maximum time the DTE will wait for an acknowledgment of a transmitted Information frame. The DTE will continue retransmissions at an interval of T200 until the tries count expires or proper acknowledgment is received from the attached equipment." ::= { cdx6500PPCTFRIPortEntry 30 } friPCfgN200 OBJECT-TYPE SYNTAX INTEGER (0..16) ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of times the DTE will retransmit in order to recover from a T200 timeout condition. If this count expires, the DTE will declare the LAPF link to be down and initiate link establishment procedures." ::= { cdx6500PPCTFRIPortEntry 31 } friPCfgWindowK OBJECT-TYPE SYNTAX INTEGER (1..32) ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum sending window size which is the maximum number (k) of sequentially numbered I frames that may be outstanding (unacknowledged) at any given time. The recommended values are: Line speed (kbps) Window, k ----------------- -------------- less than 16 3 greater than 16 7" ::= { cdx6500PPCTFRIPortEntry 32 } friPCfgT203 OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "The idle timer (T203) represents the maximum time in seconds allowed without frames being exchanged. If the link remains idle for this period of time, the DTE will send a supervisory frame with the poll bit set. A value of zero disables this timer." ::= { cdx6500PPCTFRIPortEntry 33 } friPCfgT303 OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "The Setup Timer (T303) represents the maximum time in seconds allowed without a response to a SETUP message being received. Upon expiry, the SETUP message is retransmitted and the timer is restarted. The second expiry of the timer will cause the call to be cleared." ::= { cdx6500PPCTFRIPortEntry 34 } friPCfgT305 OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The Disconnect Timer (T305) represents the maximum time in seconds allowed without a response to a DISCONNECT message being received. Upon expiry, a RELEASE message is sent." ::= { cdx6500PPCTFRIPortEntry 35 } friPCfgT308 OBJECT-TYPE SYNTAX INTEGER (1..60) ACCESS read-write STATUS mandatory DESCRIPTION "The Release Timer (T308) represents the maximum time in seconds allowed without a response to a RELEASE message being received. Upon expiry, the RELEASE message is retransmitted and the timer is restarted. The second expiry of the timer will cause the call to be cleared." ::= { cdx6500PPCTFRIPortEntry 36 } friPCfgT310 OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "The Call Proceeding Timer (T310) value is in seconds. This timer is started when a CALL PROCEEDING response to a SETUP message is received. The timer is stopped when a CONNECT or DISCONNECT or RELEASE message is received. If the timer expires, the call will be cleared." ::= { cdx6500PPCTFRIPortEntry 37 } friPCfgControlProtocol OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This option controls whether the PVC management protocol acts like a DTE or a DCE DTE - This ports takes on the the DTE or User Side role DCE - This ports takes on the the DCE or Network Side role" ::= { cdx6500PPCTFRIPortEntry 38 } friPCfguniState OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable FRF.12 UNI Segmentation. Peer must be enabled too. enable - Enable UNI Segmentation disable - Disable UNI Segmentation" -- DEFVAL { disable } ::= { cdx6500PPCTFRIPortEntry 39 } friPCfguniSSVP OBJECT-TYPE SYNTAX INTEGER { segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025) } ACCESS read-only STATUS mandatory DESCRIPTION "UNI segment size when voice is present. Affects transmit path only. segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments" -- DEFVAL { 64 } ::= { cdx6500PPCTFRIPortEntry 40 } friPCfguniSSVNP OBJECT-TYPE SYNTAX INTEGER { segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025), segSize2048 (2049), segSize4096 (4097), disable (32000) } ACCESS read-write STATUS mandatory DESCRIPTION "UNI segment size when voice is not present. Affects transmit path only. segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments segSize2048 - 2048 byte segments segSize4096 - 4096 byte segments disable - this selection doesn't affect the packet size. UNI segmentation header will be inserted only." -- DEFVAL { disable } ::= { cdx6500PPCTFRIPortEntry 41 } friPCfguniSegDelay OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Discards a packet if any segment delays more than 10 seconds. Affects receive path only. enabled - discard the packet disabled - do not discard the packet" -- DEFVAL { disable } ::= { cdx6500PPCTFRIPortEntry 42 } friPCfguniCheckPckSize OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Check if the packet size is larger than the node maximum packet size. enabled - discard packet than is larger than the maximum size. disabled - accept packet than is larger than the maximum size." -- DEFVAL { disable } ::= { cdx6500PPCTFRIPortEntry 43 } friPCfgElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PPCTFRIPortEntry 44 } friPCfgV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PPCTFRIPortEntry 45 } friPCfgHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PPCTFRIPortEntry 46 } -- The FRI Station Configuration Table -- This Table replaces cdx6500SPCTFRDTEStationTable which is now -- obsolete cdx6500SPCTFRIStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPCTFRIStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains Frame Relay DTE Station configuration parameters." ::= { cdx6500PCTStationProtocolGroup 9 } cdx6500SPCTFRIStationEntry OBJECT-TYPE SYNTAX Cdx6500SPCTFRIStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station Configuration Table." INDEX { friSCfgPortNumber, friSCfgStnNumber } ::= { cdx6500SPCTFRIStationTable 1 } -- NOTE : Numeric objects which are skipped during configuration -- will return 0 on query. Cdx6500SPCTFRIStationEntry ::= SEQUENCE { friSCfgPortNumber INTEGER, friSCfgStnNumber INTEGER, friSCfgStnType INTEGER, friSCfgDLCI INTEGER, friSCfgCommInfoRate INTEGER, friSCfgCommBurstSize INTEGER, friSCfgTransDelay INTEGER, friSCfgCongControlMode INTEGER, friSCfgLinkAddress INTEGER, friSCfgPVCChannels INTEGER, friSCfgStartingPVC INTEGER, friSCfgSVCChannels INTEGER, friSCfgStartingSVC INTEGER, friSCfgVoiceSVCChannels INTEGER, friSCfgInitialFrame INTEGER, friSCfgT1RetryTimer INTEGER, friSCfgT4PollTimer INTEGER, friSCfgN2TransmissionTries INTEGER, friSCfgKFrameWindow INTEGER, friSCfgWPacketWindow INTEGER, friSCfgPPacketSize INTEGER, friSCfgDataQUpperThreshold INTEGER, friSCfgDataQLowerThreshold INTEGER, friSCfgRestartTimer INTEGER, friSCfgResetTimer INTEGER, friSCfgCallTimer INTEGER, friSCfgClearTimer INTEGER, friSCfgX25Options DisplayString, friSCfgRestrictedConnDest DisplayString, friSCfgCUGMembership DisplayString, friSCfgBillingRecords INTEGER, friSCfgFrameSegmenter INTEGER, friSCfgVoiceCongCtrlMode INTEGER, friSCfgPeakUtilization INTEGER, friSCfgMaxInboundQueue INTEGER, friSCfgAnnexGRateReduction INTEGER, friSCfgCctType INTEGER, friSCfgCallControl INTEGER, friSCfgRetryInterval INTEGER, friSCfgCallAttempts INTEGER, friSCfgIdleInterval INTEGER, friSCfgIeNegotiation DisplayString, friSCfgSubaddress OCTET STRING, friSCfgCalledNumber OCTET STRING, friSCfgCalledSubaddress OCTET STRING, friSCfgMinCir INTEGER, friSCfgBurstExcess INTEGER, friSCfgE2EEnabled INTEGER, friSCfgE2EType INTEGER, friSCfgE2ESSVP INTEGER, friSCfgE2ESSVNP INTEGER, friSCfgE2ESegDelayEnabled INTEGER, friSCfgE2ECheckPckSize INTEGER, friSCfgvoice-header INTEGER } friSCfgPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500SPCTFRIStationEntry 1 } friSCfgStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the configured FRI Station." ::= { cdx6500SPCTFRIStationEntry 2 } friSCfgStnType OBJECT-TYPE SYNTAX INTEGER { annexG (1), bypass (2), voiceRelay (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the type of station configured. annexG - This station uses X.25 signaling for layer 3. bypass - This station type bypasses layer 3. There is no signaling for SVC's on this station. voiceRelay - Not used in the current version." ::= { cdx6500SPCTFRIStationEntry 3 } friSCfgDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The Data Link Connection Identifier (DLCI) is the unique identifier for the station on the FRI Port. Its valid range is 0, 16 - 1007. A zero value in this field places the FRI station in DLCI auto-learn mode. In auto learn mode, the station is eligible for automatic assignment of an available network DLCI. A configured value of 16-1007 must match a DLCI on the FR networking node. NOTE: When a station record is configured for the first time, the DLCI prompt displays an auto-incrementing DLCI value. The DLCI's start from 16 for station 1, and increment by one for each station configured. If the station record is not saved to memory, a default DLCI value of zero is used." ::= { cdx6500SPCTFRIStationEntry 4 } friSCfgCommInfoRate OBJECT-TYPE SYNTAX INTEGER (0..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter (CIR) specifies the rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI Station. This value is used to throttle data on the FRI station for congestion control purposes. The CIR cannot be greater than the link speed." -- DEFVAL { 16000 } ::= { cdx6500SPCTFRIStationEntry 5 } friSCfgCommBurstSize OBJECT-TYPE SYNTAX INTEGER (0..768000) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter (BC) specifies the maximum amount of data (in bits) that the Frame Relay network agrees to transfer over a time interval T = Committed Burst Size / Committed Information Rate.This must be greater than 1/20th of the Committed Information Rate.This is used for congestion control purposes." -- DEFVAL { 16000 } ::= { cdx6500SPCTFRIStationEntry 6 } friSCfgTransDelay OBJECT-TYPE SYNTAX INTEGER (1..65535) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is the expected one-way delay through the network. This is specified in milliseconds." -- DEFVAL { 50 } ::= { cdx6500SPCTFRIStationEntry 7 } friSCfgCongControlMode OBJECT-TYPE SYNTAX INTEGER { normal (1), disable (2), congested (3), limit (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the method of congestion control: normal - congestion control is normal disable - never enter Congested State (CTRL) congested - never enter a Non-Congested State (UCTRL) limit - congestion control is normal but limits the data rate to no lower than CIR. nc - Skipped during configuration" -- DEFVAL { normal } ::= { cdx6500SPCTFRIStationEntry 8 } friSCfgLinkAddress OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "The logical link address must be set to complementary values in this FRI Station and its corresponding remote FRI station: dte - station to have logical DTE address (A) dce - station to have logical DCE address (B) nc - Skipped during configuration." -- DEFVAL { dte } ::= { cdx6500SPCTFRIStationEntry 9 } friSCfgPVCChannels OBJECT-TYPE SYNTAX INTEGER (0..128) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table." -- DEFVAL { 0 } ::= { cdx6500SPCTFRIStationEntry 10 } friSCfgStartingPVC OBJECT-TYPE SYNTAX INTEGER (1..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Permanent Virtual Circuits on this FRI station. Not used if the number of PVCs = 0." -- DEFVAL { 1 } ::= { cdx6500SPCTFRIStationEntry 11 } friSCfgSVCChannels OBJECT-TYPE SYNTAX INTEGER (0..512) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs." -- DEFVAL { 16 } ::= { cdx6500SPCTFRIStationEntry 12 } friSCfgStartingSVC OBJECT-TYPE SYNTAX INTEGER (0..4095) ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the switched Virtual Circuits on this station (logical link). Not used if the number of SVCs = 0." -- DEFVAL { 1 } ::= { cdx6500SPCTFRIStationEntry 13 } friSCfgVoiceSVCChannels OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical voice channels used in Switched Virtual Circuits.The total number of voice and data channels on a station (logical link) should be kept as small as possible and consistent with needs." -- DEFVAL { 0 } ::= { cdx6500SPCTFRIStationEntry 14 } friSCfgInitialFrame OBJECT-TYPE SYNTAX INTEGER { sabm (1), disc (2), none (3), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the initial frame required by other end for (logical) link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, then SABM nc - Skipped during configuration" -- DEFVAL { sabm } ::= { cdx6500SPCTFRIStationEntry 15 } friSCfgT1RetryTimer OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-write STATUS mandatory DESCRIPTION "T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds)." -- DEFVAL { 30 } ::= { cdx6500SPCTFRIStationEntry 16 } friSCfgT4PollTimer OBJECT-TYPE SYNTAX INTEGER (10..255) ACCESS read-write STATUS mandatory DESCRIPTION "This sets the time an idle link is probed for assurance of connection to the remote FRI station. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1." -- DEFVAL { 40 } ::= { cdx6500SPCTFRIStationEntry 17 } friSCfgN2TransmissionTries OBJECT-TYPE SYNTAX INTEGER (1..20) ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of attempts allowed to complete a transmission." -- DEFVAL { 10 } ::= { cdx6500SPCTFRIStationEntry 18 } friSCfgKFrameWindow OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "Frame level window size must be set to the same value at both this FRI station and the remote FRI station." -- DEFVAL { 7 } ::= { cdx6500SPCTFRIStationEntry 19 } friSCfgWPacketWindow OBJECT-TYPE SYNTAX INTEGER (1..63) ACCESS read-write STATUS mandatory DESCRIPTION "Packet level window size must be set to the same value at both this FRI station and the remote FRI station." -- DEFVAL { 2 } ::= { cdx6500SPCTFRIStationEntry 20 } friSCfgPPacketSize OBJECT-TYPE SYNTAX INTEGER { psize32 (6), psize64 (7), psize128 (8), psize256 (9), psize512 (10), psize1024 (11), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum X.25 packet size used on the station (logical link).For proper operation, this must be set to the same value at both this FRI station and the remote FRI station." -- DEFVAL { psize128 } ::= { cdx6500SPCTFRIStationEntry 21 } friSCfgDataQUpperThreshold OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of data packets a channel on this station (logical link) will queue for transmission before invoking flow control to the attached channel" -- DEFVAL { 5 } ::= { cdx6500SPCTFRIStationEntry 22 } friSCfgDataQLowerThreshold OBJECT-TYPE SYNTAX INTEGER (0..63) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of data packets a channel on this FRI station will have queued for transmission when it releases flow control to the attached channel" -- DEFVAL { 0 } ::= { cdx6500SPCTFRIStationEntry 23 } friSCfgRestartTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Restart-Request timeout timer in seconds. If timer expires on this FRI station, the Restart request is sent again." -- DEFVAL { 180 } ::= { cdx6500SPCTFRIStationEntry 24 } friSCfgResetTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Reset-Request timeout timer in seconds. If timer expires on this FRI station, the Reset request is sent again." -- DEFVAL { 180 } ::= { cdx6500SPCTFRIStationEntry 25 } friSCfgCallTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Call-Request timeout timer in seconds. If timer expires on this FRI station, the call is cleared." -- DEFVAL { 200 } ::= { cdx6500SPCTFRIStationEntry 26 } friSCfgClearTimer OBJECT-TYPE SYNTAX INTEGER (5..255) ACCESS read-write STATUS mandatory DESCRIPTION "Clear-Request timeout timer in seconds. If timer expires on this FRI station, the Clear request is sent again." -- DEFVAL { 180 } ::= { cdx6500SPCTFRIStationEntry 27 } friSCfgX25Options OBJECT-TYPE SYNTAX DisplayString (SIZE(0..24)) ACCESS read-write STATUS mandatory DESCRIPTION "Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another vanguard device INL may be a poor choice for high speed links. INLB is set with INL to improve performance of high speed links. INLB - set with INL options to improve performance if inter-node link is a high speed link. DELAY - Enable Delay and Path Trace on this link Any combination of above specified by summing (e.g. CUG+ CAUSE+....). " ::= { cdx6500SPCTFRIStationEntry 28 } friSCfgRestrictedConnDest OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "All calls entering this station will be routed to the destination specified in this parameter,irrespective of route selection table entries. For example, to route all calls to X.25 port 3, use X25-3. To route calls to SDLC port 2, station 4, use SDLC-2S4. Blank in this field disables this function." ::= { cdx6500SPCTFRIStationEntry 29 } friSCfgCUGMembership OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) ACCESS read-write STATUS mandatory DESCRIPTION "The station may be a member of up to 8 different Closed User Groups (CUGs).Each CUG membership must be a two digit number (except --) and separated by a comma. ( e.g. 12,34,56,09,02, 03). -- - No CUG Membership 00-99 - CUG Membership" ::= { cdx6500SPCTFRIStationEntry 30 } friSCfgBillingRecords OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this FRI station. off - Billing records will not be created. on - Billing records will be created. nc - Skipped during configuration." -- DEFVAL { off } ::= { cdx6500SPCTFRIStationEntry 31 } friSCfgFrameSegmenter OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Determine if this station will support the Frame Segmenter Header.The Frame Segmenter should be enabled if the frame relay port is configured to pass voice traffic. disabled - Frame Segmenter disabled. enabled - Frame Segmenter enabled. nc - Skipped during configuration." -- DEFVAL { disabled } ::= { cdx6500SPCTFRIStationEntry 32 } friSCfgVoiceCongCtrlMode OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station operates normally Use this parameter in voice applications, when the frame relay network can have more than 140ms of data buffered. One typical application is asymmetrical speeds. When this parameter is enabled, and voice is detected, delta T is forced to 50 ms and the BC is forced to 1/20 CIR." -- DEFVAL { disabled } ::= { cdx6500SPCTFRIStationEntry 33 } friSCfgPeakUtilization OBJECT-TYPE SYNTAX INTEGER (0..240) ACCESS read-write STATUS mandatory DESCRIPTION "The monitoring interval size specifies the time period to use when monitoring peak data link/CIR (Committed Information Rate) utilization. 0 - Disables this monitoring feature. 1 to 240 - The number of 64 second increments to use for the monitoring interval time period. For example: a value of 30 specifies a time duration equal to 30 * 64 seconds = 1920 seconds or 32 minutes." -- DEFVAL { 0 } ::= { cdx6500SPCTFRIStationEntry 34 } friSCfgMaxInboundQueue OBJECT-TYPE SYNTAX INTEGER (100..2500) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the maximum number of frames from the network which may be queued in a BYPASS station. A smaller value may ve choosen for applications which experience objectable delays, if due to excessive growth of the BYPASS inbound queue." -- DEFVAL { 2500 } ::= { cdx6500SPCTFRIStationEntry 35 } friSCfgAnnexGRateReduction OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter determines whether Annex G stations will invoke implicit congestion control when a link error is detected, reducing their transmitted information rate to 1/4 CIR. The rate will be gradually increased in the normal way as non-BECN frames are received." -- DEFVAL { enabled } ::= { cdx6500SPCTFRIStationEntry 36 } friSCfgCctType OBJECT-TYPE SYNTAX INTEGER { pvc (1), svc (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Select the station circuit type defined for the Frame Relay line. pvc - station will operate on its assigned DLCI as a PVC. svc - station will operate on a selected DLCI as a SVC." ::= { cdx6500SPCTFRIStationEntry 37 } friSCfgCallControl OBJECT-TYPE SYNTAX INTEGER { auto (1), autd (2), recv (3), cnorm (4) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is used to control the calling behavior of the SVC station. auto - the station will automatically initiate a FR SVC call on power up autd - the station will initiate a FR SVC call on demand of data to transmit recv - the station can be used to receive inbound FR SVC calls from attached network equipment cnorm - Controlled Normal. This allows Annex G stations to set up and disconnect Frame Relay SVC calls through Network Services" ::= { cdx6500SPCTFRIStationEntry 38 } friSCfgRetryInterval OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the time interval between call attempts, in seconds, that a station configured to initiate an SVC call will use. If a call attempt fails, either because there was no response to the SETUP message or the response was a RELEASE, the station will wait this amount of time before sending the next SETUP message." ::= { cdx6500SPCTFRIStationEntry 39 } friSCfgCallAttempts OBJECT-TYPE SYNTAX INTEGER (0..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of contiguous call attempts that a station configured to initiate an SVC call will make to establish the call. If this count expires, the station will not make any further call attempts. A station (or port or node) boot is required to re-initiate call attempts. A value of 0 means the station makes call attempts indefinitely." ::= { cdx6500SPCTFRIStationEntry 40 } friSCfgIdleInterval OBJECT-TYPE SYNTAX INTEGER (10..255) ACCESS read-write STATUS mandatory DESCRIPTION "This is the idle time, in seconds, allowed for FRI station to remain idle. If the station using the SVC passes no data for this time period, the SVC will be cleared. If the SVC is cleared and the stations attempts to send data an SVC will be established for the station." ::= { cdx6500SPCTFRIStationEntry 41 } friSCfgIeNegotiation OBJECT-TYPE SYNTAX DisplayString ACCESS read-write STATUS mandatory DESCRIPTION "This allows the listing of parameters to be used in a SETUP/CONNECT message. dlci - If the station initiates a call, it will select the lowest value of DLCI available and specify it to be used for the SVC. llcp - If the station initiates a call it specifies a full set of Link Layer Core Parameters. If it receives a call LLCP is used to set CIR and BC. tpie - If set, the station will send a Traffic Priority IE. The value of the TP IE is determined by the application that causes the call to be made. This parameter is only effective on stations configured for CNORM Call Control. Any combination of above specified by summing (DLCI+LLCP)." ::= { cdx6500SPCTFRIStationEntry 42 } friSCfgSubaddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..6)) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the station subaddress coded and an IE. it is coded as an IA5 string with type of subaddress NSAP and IA5 AFI prefix added. Incoming calls with a called subaddress of NSAP type and IA5 AFI prefix that match this configured string will connect to this station. If this parameter is blank, the corresponding IE is not sent on outgoing calls. Incoming calls without the corresponding IE can connect to this station. The valid format of this entry is: xx...xx000000 or xx...xx000000 Where: xx...xx00 represents the station number in IA5/ASCII coded hex terminated with a NUL character suffix. For example, a sub-address of 12 would be represented by the string 313200. To set the subaddress blank, set the address string to NUL only." ::= { cdx6500SPCTFRIStationEntry 43 } friSCfgCalledNumber OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..19)) ACCESS read-write STATUS mandatory DESCRIPTION "This is the address of the destination, in the appropriate numbering plan, to which a call will be placed by this station. Called Party Number is a manditory IE and should be specified if calls are originated by this station. The valid format of this entry is: xx...xx000101 or xx...xx000103 Where: xx...xx00 represents the address of the destination in IA5/ASCII coded hex terminated with a NUL character suffix. For example, an address of 123 would be represented by the string 31323300. 0101 is the suffix used to specify E.164 Number Plan 0103 is the suffix used to specify X.121 Number Plan" ::= { cdx6500SPCTFRIStationEntry 44 } friSCfgCalledSubaddress OBJECT-TYPE SYNTAX OCTET STRING (SIZE(3..6)) ACCESS read-write STATUS mandatory DESCRIPTION "For outgoing calls, this specifies the calling subaddress IE coded as an IA5 string with type of subaddress NSAP and IA5 AFI prefix added. Incoming calls with a called subaddress of NSAP type and IA5 AFI prefix that match this configured string will connect to this station. If this parameter is blank, the corresponding IE is not sent on outgoing calls. Incoming calls without the corresponding IE can connect to this station. The valid format of this entry is: xx...xx000000 or xx...xx000000 Where: xx...xx00 represents the station number in IA5/ASCII coded hex terminated with a NUL character suffix. For example, a sub-address of 12 would be represented by the string 313200. To set the subaddress blank, set the address string to NUL only." ::= { cdx6500SPCTFRIStationEntry 45 } friSCfgMinCir OBJECT-TYPE SYNTAX INTEGER (0..155000000) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies the minimum rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI Station. This value is used to throttle data on the FRI station for congestion control purposes. The MinCIR cannot be greater than the link speed." ::= { cdx6500SPCTFRIStationEntry 46 } friSCfgBurstExcess OBJECT-TYPE SYNTAX INTEGER (0..4096000) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is negotiated during the call establishment phase of Frame Relay SVC calls. It has no effect on data transfer after the call has been established." ::= { cdx6500SPCTFRIStationEntry 47 } friSCfgE2EEnabled OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Enable End-to-End Segmentation. Peer must be enabled too. enabled - Enable End-to-End Segmentation disabled - Disable End-to-End Segmentation" -- DEFVAL { disable } ::= { cdx6500SPCTFRIStationEntry 48 } friSCfgE2EType OBJECT-TYPE SYNTAX INTEGER { motorola (1), frf12 (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Type of End-to-End Segmentation. Peer must be configured in the same way. FRF12 - FRF.12 End-to-End Segmentation Motorola - Motorola End-to-End Segmentation" -- DEFVAL { FRF12 } ::= { cdx6500SPCTFRIStationEntry 49 } friSCfgE2ESSVP OBJECT-TYPE SYNTAX INTEGER { segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025) } ACCESS read-only STATUS mandatory DESCRIPTION "Segment size when voice is present. Affects transmit path only. segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments" -- DEFVAL { 64 } ::= { cdx6500SPCTFRIStationEntry 50 } friSCfgE2ESSVNP OBJECT-TYPE SYNTAX INTEGER { segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025), segSize2048 (2049), segSize4096 (4097), disable (32000) } ACCESS read-write STATUS mandatory DESCRIPTION "Segment size when voice is not present. Affects transmit path only. segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments segSize2048 - 2048 byte segments segSize4096 - 4096 byte segments disable - this selection doesn't affect the packet size. End-to-End segmentation header will be inserted only." -- DEFVAL { disable } ::= { cdx6500SPCTFRIStationEntry 51 } friSCfgE2ESegDelayEnabled OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Discards a packet if any segment delays more than 10 seconds. Affects receive path only. enabled - discard the packet disabled - do not discard the packet" -- DEFVAL { disable } ::= { cdx6500SPCTFRIStationEntry 52 } friSCfgE2ECheckPckSize OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Check if the packet size is larger than the node maximum packet size. enabled - discard packet than is larger than the maximum size. disabled - accept packet than is larger than the maximum size." -- DEFVAL { disable } ::= { cdx6500SPCTFRIStationEntry 53 } friSCfgvoice-header OBJECT-TYPE SYNTAX INTEGER { disable (1), enable (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Voice Header. enabled - Enable Voice Header Insertion disabled - Disable Voice Header Insertion" -- DEFVAL { disable } ::= { cdx6500SPCTFRIStationEntry 54 } -- FRI Port Statistics Table -- This table replaces cdx6500PPSTFRDTEPortTable which is now -- obsolete cdx6500PPSTFRIPStatsTable OBJECT IDENTIFIER ::= { cdx6500PSTPortProtocolGroup 32 } cdx6500PPSTFRIPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTFRIPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Port Statistics parameters." ::= { cdx6500PPSTFRIPStatsTable 1 } cdx6500PPSTFRIPortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTFRIPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Port Statistics Table." INDEX { friPStatsPortNumber } ::= { cdx6500PPSTFRIPortTable 1 } Cdx6500PPSTFRIPortEntry ::= SEQUENCE { friPStatsPortNumber INTEGER, friPStatsPortType INTEGER, friPStatsPortStatus INTEGER, friPStatsConfiguredStns DisplayString, friPStatsPortSpeed INTEGER, friPStatsOpCntrlProtocol DisplayString, friPStatsSPBackup DisplayString, friPStatsPriorityStn INTEGER, friPStatsLastStatsReset DisplayString } friPStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the FRI port." ::= { cdx6500PPSTFRIPortEntry 1 } friPStatsPortType OBJECT-TYPE SYNTAX INTEGER { fri(17) } ACCESS read-only STATUS mandatory DESCRIPTION "Port type of this port." ::= { cdx6500PPSTFRIPortEntry 2 } friPStatsPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), busyOut (3), up (4), down (5), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current port status. enabled - Port is operational. disabled - Port has been disabled. busyOut - Port has been busied out. up - Port is up and operational. down - Port is down. na - Value not Available." ::= { cdx6500PPSTFRIPortEntry 3 } friPStatsConfiguredStns OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "A list of all the configured stations." ::= { cdx6500PPSTFRIPortEntry 4 } friPStatsPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Message transmission speed in bits per second. " ::= { cdx6500PPSTFRIPortEntry 5 } friPStatsOpCntrlProtocol OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Control Protocol type learned from network." ::= { cdx6500PPSTFRIPortEntry 6 } friPStatsSPBackup OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates whether the same port backup is configured for this port." ::= { cdx6500PPSTFRIPortEntry 7 } friPStatsPriorityStn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the high priority station." ::= { cdx6500PPSTFRIPortEntry 8 } friPStatsLastStatsReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the time stamp of the last statistics reset." ::= { cdx6500PPSTFRIPortEntry 9 } cdx6500PPSTFRIDataSummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTFRIDataSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Port Data Summary Statistics parameters." ::= { cdx6500PPSTFRIPStatsTable 2 } cdx6500PPSTFRIDataSummaryEntry OBJECT-TYPE SYNTAX Cdx6500PPSTFRIDataSummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Port Data Summary Statistics Table." INDEX { friDataSummPortNumber } ::= { cdx6500PPSTFRIDataSummaryTable 1 } Cdx6500PPSTFRIDataSummaryEntry ::= SEQUENCE { friDataSummPortNumber INTEGER, friPStatsCharInTotal Counter, friPStatsCharOutTotal Counter, friPStatsCharInPerSec INTEGER, friPStatsCharOutPerSec INTEGER, friPStatsFramesInTotal Counter, friPStatsFramesOutTotal Counter, friPStatsFramesInPerSec INTEGER, friPStatsFramesOutPerSec INTEGER, friPStatsAvFrameSizeIn INTEGER, friPStatsAvFrameSizeOut INTEGER, friPStatsUtilIn INTEGER, friPStatsUtilOut INTEGER } friDataSummPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the FRI port." ::= { cdx6500PPSTFRIDataSummaryEntry 1 } friPStatsCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received since last boot or statistics reset." ::= { cdx6500PPSTFRIDataSummaryEntry 2 } friPStatsCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters transmitted since last boot or statistics reset." ::= { cdx6500PPSTFRIDataSummaryEntry 3 } friPStatsCharInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second." ::= { cdx6500PPSTFRIDataSummaryEntry 4 } friPStatsCharOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters transmitted per second." ::= { cdx6500PPSTFRIDataSummaryEntry 5 } friPStatsFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last boot or statistics reset." ::= { cdx6500PPSTFRIDataSummaryEntry 6 } friPStatsFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted since last boot or statistics reset." ::= { cdx6500PPSTFRIDataSummaryEntry 7 } friPStatsFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second." ::= { cdx6500PPSTFRIDataSummaryEntry 8 } friPStatsFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames transmitted per second." ::= { cdx6500PPSTFRIDataSummaryEntry 9 } friPStatsAvFrameSizeIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average frame size of received frames." ::= { cdx6500PPSTFRIDataSummaryEntry 10 } friPStatsAvFrameSizeOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average size of transmitted frames." ::= { cdx6500PPSTFRIDataSummaryEntry 11 } friPStatsUtilIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port Utilization of incoming data." ::= { cdx6500PPSTFRIDataSummaryEntry 12 } friPStatsUtilOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Port Utilization of outgoing data." ::= { cdx6500PPSTFRIDataSummaryEntry 13 } cdx6500PPSTFRISummaryTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTFRISummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Summary Statistics parameters." ::= { cdx6500PPSTFRIPStatsTable 3 } cdx6500PPSTFRISummaryEntry OBJECT-TYPE SYNTAX Cdx6500PPSTFRISummaryEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Summary Statistics Table." INDEX { friSummPortNumber } ::= { cdx6500PPSTFRISummaryTable 1 } Cdx6500PPSTFRISummaryEntry ::= SEQUENCE { friSummPortNumber INTEGER, friPStatsCRCErrors Counter, friPStatsOverrunErrors Counter, friPStatsFrameLengthErrors Counter, friPStatsUnderrunErrors Counter, friPStatsUnknownDLCICount Counter, friPStatsLastUnknownDLCI INTEGER, friPStatsSplittingRatio INTEGER, friPStatsTotalSegmentsLost INTEGER, friPStatsMaxContiguousSegmentsLost INTEGER, friPStatsVoiceBWOnPort INTEGER, friPStatsFrameSegmenterSyncLost INTEGER, friPStatsStatusEnqSentFull INTEGER, friPStatsFullStatusRecd INTEGER, friPStatsStatusEnqSentLIV INTEGER, friPStatsLIVStatusRecd INTEGER, friPStatsStatusEnqRecdFull INTEGER, friPStatsStatusEnqRecdLIV INTEGER, friPStatsAsyncUpdateRecd INTEGER, friPStatsSeqNumMismatch INTEGER, friPStatsTimeouts INTEGER } friSummPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the FRI port." ::= { cdx6500PPSTFRISummaryEntry 1 } friPStatsCRCErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of errors detected by Cyclic Redundancy Check since last node boot or reset of statistics." ::= { cdx6500PPSTFRISummaryEntry 2 } friPStatsOverrunErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of OverrunErrors detected since last node boot or reset of statistics." ::= { cdx6500PPSTFRISummaryEntry 3 } friPStatsFrameLengthErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Frame Length Errors detected since last node boot or statistics reset." ::= { cdx6500PPSTFRISummaryEntry 4 } friPStatsUnderrunErrors OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Underrun Errors detected since last node boot or statistics reset." ::= { cdx6500PPSTFRISummaryEntry 5 } friPStatsUnknownDLCICount OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the number of DLCIs not recognized." ::= { cdx6500PPSTFRISummaryEntry 6 } friPStatsLastUnknownDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "This specifies the last unknown dlci received." ::= { cdx6500PPSTFRISummaryEntry 7 } friPStatsSplittingRatio OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The Frame Segmenter's splitting ratio calculated as a percentage of Number of frames segmented/Number of frames." ::= { cdx6500PPSTFRISummaryEntry 8 } friPStatsTotalSegmentsLost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total Segments lost by Frame Segmenter Receiver." ::= { cdx6500PPSTFRISummaryEntry 9 } friPStatsMaxContiguousSegmentsLost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum consecutive segments lost by Farme Segmenter Receiver." ::= { cdx6500PPSTFRISummaryEntry 10 } friPStatsVoiceBWOnPort OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current amount of voice bandwidth allocated." ::= { cdx6500PPSTFRISummaryEntry 11 } friPStatsFrameSegmenterSyncLost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of times synchronization has been lost." ::= { cdx6500PPSTFRISummaryEntry 12 } friPStatsStatusEnqSentFull OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of status enquiries SENT FULL." ::= { cdx6500PPSTFRISummaryEntry 13 } friPStatsFullStatusRecd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of full status received." ::= { cdx6500PPSTFRISummaryEntry 14 } friPStatsStatusEnqSentLIV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of status enq sent LIV." ::= { cdx6500PPSTFRISummaryEntry 15 } friPStatsLIVStatusRecd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of status update received." ::= { cdx6500PPSTFRISummaryEntry 16 } friPStatsStatusEnqRecdFull OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Full status enq RCV bi-directional mode." ::= { cdx6500PPSTFRISummaryEntry 17 } friPStatsStatusEnqRecdLIV OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of LIV status enq RCV bi-directional mode." ::= { cdx6500PPSTFRISummaryEntry 18 } friPStatsAsyncUpdateRecd OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of async update received." ::= { cdx6500PPSTFRISummaryEntry 19 } friPStatsSeqNumMismatch OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Sequence Number Mismatches occurred." ::= { cdx6500PPSTFRISummaryEntry 20 } friPStatsTimeouts OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of timeouts occurred." ::= { cdx6500PPSTFRISummaryEntry 21 } cdx6500PPSTFRIISDNCallStatusTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTFRIISDNCallStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI ISDN Statistics parameters." ::= { cdx6500PPSTFRIPStatsTable 4 } cdx6500PPSTFRIISDNCallStatusEntry OBJECT-TYPE SYNTAX Cdx6500PPSTFRIISDNCallStatusEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI ISDN Statistics Table." INDEX { friISDNCallStatusPortNumber } ::= { cdx6500PPSTFRIISDNCallStatusTable 1 } Cdx6500PPSTFRIISDNCallStatusEntry ::= SEQUENCE { friISDNCallStatusPortNumber INTEGER, friPStatsNumRxCallsSinceLastReset INTEGER, friPStatsNumRxCallsRejected INTEGER, friPStatsRxLastCallFailureCause INTEGER, friPStatsRxLastCalledNumber DisplayString, friPStatsRxLastCallingNumber DisplayString, friPStatsRxMinCallDuration DisplayString, friPStatsRxMaxCallDuration DisplayString, friPStatsRxAvgCallDuration DisplayString, friPStatsNumTxCallsSinceLastReset INTEGER, friPStatsNumTxCallsRejected INTEGER, friPStatsTxLastCallFailureCause INTEGER, friPStatsTxLastCalledNumber DisplayString, friPStatsTxLastCallingNumber DisplayString, friPStatsTxMinCallDuration DisplayString, friPStatsTxMaxCallDuration DisplayString, friPStatsTxAvgCallDuration DisplayString, friPStatsSignalingState INTEGER } friISDNCallStatusPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The port number of the FRI Port." ::= { cdx6500PPSTFRIISDNCallStatusEntry 1 } friPStatsNumRxCallsSinceLastReset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound calls that were attempted since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 2 } friPStatsNumRxCallsRejected OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of inbound calls that were rejected since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 3 } friPStatsRxLastCallFailureCause OBJECT-TYPE SYNTAX INTEGER { noFailureReported (193), noAvailableVirtualPort (194), securityViolation (195), noResourcesAvailable (196), callRejected (197), invalidPhoneNumber (198), outgoingCallRequestTimeout (199), callCollision (200), virtualPortNotAvailable (201), invalidConfiguration (202), failureNotSupported (203), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason the last inbound call was rejected, since the last statistics reset. The posssible values are: noFailureReported - No call failure noAvailableVirtualPort - No virtual port available securityViolation - Password security failed noResourcesAvailable - No resources available callRejected - Call failed by Xircom card invalidPhoneNumber - Phone number is incorrect outgoingCallRequestTimeout - Outgoing call request timed out callCollision - Call collision virtualPortNotAvailable - This port is not available invalidConfiguration - Configuration is incorrect failureNotSupported - Failure is not supported na - Value Not Available." ::= { cdx6500PPSTFRIISDNCallStatusEntry 4 } friPStatsRxLastCalledNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of the virtual port of the last ISDN call made into this port." ::= { cdx6500PPSTFRIISDNCallStatusEntry 5 } friPStatsRxLastCallingNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of last party to make an ISDN call into this port." ::= { cdx6500PPSTFRIISDNCallStatusEntry 6 } friPStatsRxMinCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The minimum call duration of all inbound ISDN calls made into this port, since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 7 } friPStatsRxMaxCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The maximum call duration of all inbound ISDN calls made into this port, since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 8 } friPStatsRxAvgCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The average call duration of all inbound ISDN calls made into this port, since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 9 } friPStatsNumTxCallsSinceLastReset OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound calls that were attempted since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 10 } friPStatsNumTxCallsRejected OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of outbound calls that were rejected since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 11 } friPStatsTxLastCallFailureCause OBJECT-TYPE SYNTAX INTEGER { noFailureReported (193), noAvailableVirtualPort (194), securityViolation (195), noResourcesAvailable (196), callRejected (197), invalidPhoneNumber (198), outgoingCallRequestTimeout (199), callCollision (200), virtualPortNotAvailable (201), invalidConfiguration (202), failureNotSupported (203), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "The reason the last outbound call was rejected, since the last statistics reset. The posssible values are: noFailureReported - No call failure noAvailableVirtualPort - No virtual port available securityViolation - Password security failed noResourcesAvailable - No resources available callRejected - Call failed by Xircom card invalidPhoneNumber - Phone number is incorrect outgoingCallRequestTimeout - Outgoing call request timed out callCollision - Call collision virtualPortNotAvailable - This port is not available invalidConfiguration - Configuration is incorrect failureNotSupported - Failure is not supported na - Value Not Available." ::= { cdx6500PPSTFRIISDNCallStatusEntry 12 } friPStatsTxLastCalledNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of the last ISDN call made by a virtual port from this port." ::= { cdx6500PPSTFRIISDNCallStatusEntry 13 } friPStatsTxLastCallingNumber OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The phone number of the virtual port that made the last ISDN call from this port." ::= { cdx6500PPSTFRIISDNCallStatusEntry 14 } friPStatsTxMinCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The minimum call duration of all outbound ISDN calls made from this port, since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 15 } friPStatsTxMaxCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The maximum call duration of all outbound ISDN calls made from this port, since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 16 } friPStatsTxAvgCallDuration OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "The average call duration of all outbound ISDN calls made from this port, since the last statistics reset." ::= { cdx6500PPSTFRIISDNCallStatusEntry 17 } friPStatsSignalingState OBJECT-TYPE SYNTAX INTEGER { idle (1), ringing (2), connected (3), congested (4), disabled (5), dChannelDown (6), disabledDChannelDown (7), disconnecting (8), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "ISDN call signaling state. The possible values are: idle - No ISDN call present. ringing - Pending outgoing ISDN call request. connected - ISDN call is connected. congested - Congested mode. disabled - Virtual Port is disabled. dChannelDown - D-channel is down. disabledDChannelDown - Disabled and D-channel is down. disconnecting - Pending ISDN call disconnection. na - Value not available." ::= { cdx6500PPSTFRIISDNCallStatusEntry 18 } -- FRI Station Statistics Table -- This table replaces cdx6500SPSTFRDTEStationTable which is now -- obsolete cdx6500SPSTFRISStatsTable OBJECT IDENTIFIER ::= { cdx6500PSTStationProtocolGroup 10 } -- General FRI Statistics Table friSGenStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500friSGenStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Station Statistics parameters." ::= { cdx6500SPSTFRISStatsTable 1 } cdx6500friSGenStatsEntry OBJECT-TYPE SYNTAX Cdx6500friSGenStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station Statistics Table." INDEX { friSGenStatsPortNumber, friSGenStatsStnNumber } ::= { friSGenStatsTable 1 } Cdx6500friSGenStatsEntry ::= SEQUENCE { friSGenStatsPortNumber INTEGER, friSGenStatsStnNumber INTEGER, friSStatsStnType INTEGER, friSStatsStnStatus DisplayString, friSStatsDLCI INTEGER, friSStatsStnState DisplayString, friSStatsConfiguredCIR INTEGER, friSStatsAllowedInfoRate INTEGER, friSStatsImpCongDetect INTEGER, friSStatsExpCongDetect INTEGER, friSStatsLMIFlowCntrl INTEGER, friSStatsMaxSVCCount INTEGER, friSStatsCurrSVCCount INTEGER, friSStatsMaxPVCCount INTEGER, friSStatsCurrPVCCount INTEGER, friSStatsLastStatsReset DisplayString, friSStatsFrameSegState DisplayString, friSStatsFrameSegSyncLost INTEGER, friSStatsPVCState DisplayString, friSStatsVoiceCongDetect INTEGER, friSStatsMaxVSVCCount INTEGER, friSStatsCurrVSVCCount INTEGER } friSGenStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500friSGenStatsEntry 1 } friSGenStatsStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI Station." ::= { cdx6500friSGenStatsEntry 2 } friSStatsStnType OBJECT-TYPE SYNTAX INTEGER { annexG (1), bypass (2), voice (3) } ACCESS read-only STATUS mandatory DESCRIPTION "annex G - Annex G station type. bypass - bypass station type. voice - voice station type." ::= { cdx6500friSGenStatsEntry 3 } friSStatsStnStatus OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Status of the station." ::= { cdx6500friSGenStatsEntry 4 } friSStatsDLCI OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Data Link Connection Identifier is the unique identifier for the station on the FRI port and must match the DLCI configured on the Frame Relay networking node. The DLCI is 0 in Auto-Learning mode." ::= { cdx6500friSGenStatsEntry 5 } friSStatsStnState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the state of the station : unused - station is unconfigured/disabled uncontrolled - station is not controlled. controlled - station is controlled, congestion detected." ::= { cdx6500friSGenStatsEntry 6 } friSStatsConfiguredCIR OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Committed Information Rate in bits per second : Value of this parameter is 0 for Bypass stations (not available)." ::= { cdx6500friSGenStatsEntry 7 } friSStatsAllowedInfoRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Allowed information rate is the link speed if uncongested, 0 if unused and the current desired information rate if congested. Value of this parameter is also 0 for Bypass stations (not available)." ::= { cdx6500friSGenStatsEntry 8 } friSStatsImpCongDetect OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times implicit congestion procedures have been invoked.Value of this parameter is 0 for Bypass stations (not available)." ::= { cdx6500friSGenStatsEntry 9 } friSStatsExpCongDetect OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times explicit congestion procedures have been invoked." ::= { cdx6500friSGenStatsEntry 10 } friSStatsLMIFlowCntrl OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the flow status, whether OFF or ON. na - Value not available." ::= { cdx6500friSGenStatsEntry 11 } friSStatsMaxSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of SVCs available in the network. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSGenStatsEntry 12 } friSStatsCurrSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of SVCs currently in use. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSGenStatsEntry 13 } friSStatsMaxPVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of async pvc channels. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSGenStatsEntry 14 } friSStatsCurrPVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of async pvc channels. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSGenStatsEntry 15 } friSStatsLastStatsReset OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "This indicates the time stamp of the last statistics reset." ::= { cdx6500friSGenStatsEntry 16 } friSStatsFrameSegState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "State of the Frame segmenter receiver." ::= { cdx6500friSGenStatsEntry 17 } friSStatsFrameSegSyncLost OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Total number of segments lost by Frame Segmenter Receiver." ::= { cdx6500friSGenStatsEntry 18 } friSStatsPVCState OBJECT-TYPE SYNTAX DisplayString ACCESS read-only STATUS mandatory DESCRIPTION "Current state of the PVC. Value of this parameter is not available for stations other than Bypass Stations." ::= { cdx6500friSGenStatsEntry 19 } friSStatsVoiceCongDetect OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of times voice congestion procedures have been invoked. Value of this parameter is 0 (Not Available) for Bypass stations." ::= { cdx6500friSGenStatsEntry 20 } friSStatsMaxVSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of Voice SVCs available in the network. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSGenStatsEntry 21 } friSStatsCurrVSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of Voice SVCs currently in use. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSGenStatsEntry 22 } -- Data Summary Statistics Table friSDataSummaryStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500friSDataSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Station Data Summary Statistics parameters." ::= { cdx6500SPSTFRISStatsTable 2 } cdx6500friSDataSummaryStatsEntry OBJECT-TYPE SYNTAX Cdx6500friSDataSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station Data Summary Statistics Table." INDEX { friSDataSummStatsPortNumber, friSDataSummStatsStnNumber } ::= { friSDataSummaryStatsTable 1 } Cdx6500friSDataSummaryStatsEntry ::= SEQUENCE { friSDataSummStatsPortNumber INTEGER, friSDataSummStatsStnNumber INTEGER, friSStatsCharInTotal Counter, friSStatsCharOutTotal Counter, friSStatsCharInPerSec INTEGER, friSStatsCharOutPerSec INTEGER, friSStatsPktInTotal Counter, friSStatsPktOutTotal Counter, friSStatsPktInPerSec INTEGER, friSStatsPktOutPerSec INTEGER, friSStatsFrameInTotal Counter, friSStatsFrameOutTotal Counter, friSStatsFrameInPerSec INTEGER, friSStatsFrameOutPerSec INTEGER, friSStatsUtilIn INTEGER, friSStatsUtilOut INTEGER, friSStatsNumPktsQueued INTEGER, friSStatsPktsDiscardIn INTEGER, friSStatsPktsDiscardOut INTEGER, friSStatsPktsQueuedIn INTEGER, friSStatsPktsQueuedOut INTEGER } friSDataSummStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500friSDataSummaryStatsEntry 1 } friSDataSummStatsStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI station." ::= { cdx6500friSDataSummaryStatsEntry 2 } friSStatsCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received since last node boot or statistics reset." ::= { cdx6500friSDataSummaryStatsEntry 3 } friSStatsCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters transmitted since last node boot or statistics reset." ::= { cdx6500friSDataSummaryStatsEntry 4 } friSStatsCharInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second." ::= { cdx6500friSDataSummaryStatsEntry 5 } friSStatsCharOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters transmitted per second." ::= { cdx6500friSDataSummaryStatsEntry 6 } friSStatsPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets received since last node boot or statistics reset. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSDataSummaryStatsEntry 7 } friSStatsPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets transmitted since last node boot or statistics reset. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSDataSummaryStatsEntry 8 } friSStatsPktInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of packets received per second. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSDataSummaryStatsEntry 9 } friSStatsPktOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of packets transmitted per second. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSDataSummaryStatsEntry 10 } friSStatsFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted since last node boot or statistics reset." ::= { cdx6500friSDataSummaryStatsEntry 11 } friSStatsFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted since last node boot or statistics reset." ::= { cdx6500friSDataSummaryStatsEntry 12 } friSStatsFrameInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second." ::= { cdx6500friSDataSummaryStatsEntry 13 } friSStatsFrameOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames transmitted per second." ::= { cdx6500friSDataSummaryStatsEntry 14 } friSStatsUtilIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the quantity of user bytes received on the link expressed as a percentage of the maximum number of bytes that could have been received." ::= { cdx6500friSDataSummaryStatsEntry 15 } friSStatsUtilOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent." ::= { cdx6500friSDataSummaryStatsEntry 16 } friSStatsNumPktsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of packets buffered since last node boot or statistics reset. Value of this parameter is 0 for Bypass stations (not available)" ::= { cdx6500friSDataSummaryStatsEntry 17 } friSStatsPktsDiscardIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of incoming packets discarded. Value of this parameter is only available for Bypass stations, 0 is returned otherwise." ::= { cdx6500friSDataSummaryStatsEntry 18 } friSStatsPktsDiscardOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of outgoing packets discarded. Value of this parameter is only available for Bypass stations, 0 is returned otherwise." ::= { cdx6500friSDataSummaryStatsEntry 19 } friSStatsPktsQueuedIn OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Incoming packets buffered since last node boot or statistics reset of a Bypass station. Value of this parameter is only available for Bypass stations, 0 is returned otherwise." ::= { cdx6500friSDataSummaryStatsEntry 20 } friSStatsPktsQueuedOut OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of Outgoing packets buffered since last node boot or statistics reset of a Bypass station. Value of this parameter is only available for Bypass stations, 0 is returned otherwise." ::= { cdx6500friSDataSummaryStatsEntry 21 } -- Voice Summary Statistics Table friSVoiceSummaryStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500friSVoiceSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Station Voice Summary Statistics parameters." ::= { cdx6500SPSTFRISStatsTable 3 } cdx6500friSVoiceSummaryStatsEntry OBJECT-TYPE SYNTAX Cdx6500friSVoiceSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station Voice Summary Statistics Table. NOTE : Value of all objects in this table will be 0 for Bypass stations (not available)." INDEX { friSVoiceSummStatsPortNumber, friSVoiceSummStatsStnNumber } ::= { friSVoiceSummaryStatsTable 1 } Cdx6500friSVoiceSummaryStatsEntry ::= SEQUENCE { friSVoiceSummStatsPortNumber INTEGER, friSVoiceSummStatsStnNumber INTEGER, friSStatsVoiceCharInTotal Counter, friSStatsVoiceCharOutTotal Counter, friSStatsVoiceCharInPerSec INTEGER, friSStatsVoiceCharOutPerSec INTEGER, friSStatsVoicePktInTotal Counter, friSStatsVoicePktOutTotal Counter, friSStatsVoicePktInPerSec INTEGER, friSStatsVoicePktOutPerSec INTEGER } friSVoiceSummStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500friSVoiceSummaryStatsEntry 1 } friSVoiceSummStatsStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI station." ::= { cdx6500friSVoiceSummaryStatsEntry 2 } friSStatsVoiceCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of voice characters received." ::= { cdx6500friSVoiceSummaryStatsEntry 3 } friSStatsVoiceCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of voice characters transmitted." ::= { cdx6500friSVoiceSummaryStatsEntry 4 } friSStatsVoiceCharInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of voice characters received per second." ::= { cdx6500friSVoiceSummaryStatsEntry 5 } friSStatsVoiceCharOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of voice characters transmitted per second." ::= { cdx6500friSVoiceSummaryStatsEntry 6 } friSStatsVoicePktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of voice packets received." ::= { cdx6500friSVoiceSummaryStatsEntry 7 } friSStatsVoicePktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Total number of voice packets transmitted." ::= { cdx6500friSVoiceSummaryStatsEntry 8 } friSStatsVoicePktInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of voice packets received per second." ::= { cdx6500friSVoiceSummaryStatsEntry 9 } friSStatsVoicePktOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Number of voice packets transmitted per second." ::= { cdx6500friSVoiceSummaryStatsEntry 10 } -- Frame Summary Statistics Table friSFrameSummaryStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500friSFrameSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Station Frame Summary Statistics parameters." ::= { cdx6500SPSTFRISStatsTable 4 } cdx6500friSFrameSummaryStatsEntry OBJECT-TYPE SYNTAX Cdx6500friSFrameSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station Frame Summary Statistics Table. NOTE : Value of all objects in this table will be 0 for Bypass stations (not available)" INDEX { friSFrameSummStatsPortNumber, friSFrameSummStatsStnNumber } ::= { friSFrameSummaryStatsTable 1 } Cdx6500friSFrameSummaryStatsEntry ::= SEQUENCE { friSFrameSummStatsPortNumber INTEGER, friSFrameSummStatsStnNumber INTEGER, friSStatsInfoFramesInTotal Counter, friSStatsInfoFramesOutTotal Counter, friSStatsRRFramesInTotal Counter, friSStatsRRFramesOutTotal Counter, friSStatsRNRFramesInTotal Counter, friSStatsRNRFramesOutTotal Counter, friSStatsREJFramesInTotal Counter, friSStatsREJFramesOutTotal Counter, friSStatsSABMFramesInTotal Counter, friSStatsSABMFramesOutTotal Counter, friSStatsDISCFramesInTotal Counter, friSStatsDISCFramesOutTotal Counter, friSStatsDMFramesInTotal Counter, friSStatsDMFramesOutTotal Counter, friSStatsUAFramesInTotal Counter, friSStatsUAFramesOutTotal Counter, friSStatsFRMRFramesInTotal Counter, friSStatsFRMRFramesOutTotal Counter } friSFrameSummStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500friSFrameSummaryStatsEntry 1 } friSFrameSummStatsStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI station." ::= { cdx6500friSFrameSummaryStatsEntry 2 } friSStatsInfoFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Information Frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 3 } friSStatsInfoFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Information Frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 4 } friSStatsRRFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RR Frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 5 } friSStatsRRFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RR Frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 6 } friSStatsRNRFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RNR frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 7 } friSStatsRNRFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RNR frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 8 } friSStatsREJFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of REJ frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 9 } friSStatsREJFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of REJ frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 10 } friSStatsSABMFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of SABM frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 11 } friSStatsSABMFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of SABM frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 12 } friSStatsDISCFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of DISC frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 13 } friSStatsDISCFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of DISC frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 14 } friSStatsDMFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of DM frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 15 } friSStatsDMFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of DM frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 16 } friSStatsUAFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of UA frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 17 } friSStatsUAFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of UA frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 18 } friSStatsFRMRFramesInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of FRMR frames received since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 19 } friSStatsFRMRFramesOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of FRMR frames transmitted since last node boot or statistics reset." ::= { cdx6500friSFrameSummaryStatsEntry 20 } -- Packet Summary Statistics Table friSPacketSummaryStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500friSPacketSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Station Packet Summary Statistics parameters." ::= { cdx6500SPSTFRISStatsTable 5 } cdx6500friSPacketSummaryStatsEntry OBJECT-TYPE SYNTAX Cdx6500friSPacketSummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station Packet Summary Statistics Table. NOTE : Value of all objects in this table will be 0 for Bypass stations (not available)" INDEX { friSPktSummStatsPortNumber, friSPktSummStatsStnNumber } ::= { friSPacketSummaryStatsTable 1 } Cdx6500friSPacketSummaryStatsEntry ::= SEQUENCE { friSPktSummStatsPortNumber INTEGER, friSPktSummStatsStnNumber INTEGER, friSStatsDataPktInTotal Counter, friSStatsDataPktOutTotal Counter, friSStatsRRPktInTotal Counter, friSStatsRRPktOutTotal Counter, friSStatsRNRPktInTotal Counter, friSStatsRNRPktOutTotal Counter, friSStatsREJPktInTotal Counter, friSStatsREJPktOutTotal Counter, friSStatsCallReqPktInTotal Counter, friSStatsCallReqPktOutTotal Counter, friSStatsCallAccPktInTotal Counter, friSStatsCallAccPktOutTotal Counter, friSStatsClrReqPktInTotal Counter, friSStatsClrReqPktOutTotal Counter, friSStatsClrConfPktInTotal Counter, friSStatsClrConfPktOutTotal Counter, friSStatsIntrReqPktInTotal Counter, friSStatsIntrReqPktOutTotal Counter, friSStatsIntrConfPktInTotal Counter, friSStatsIntrConfPktOutTotal Counter, friSStatsResetReqPktInTotal Counter, friSStatsResetReqPktOutTotal Counter, friSStatsResetConfPktInTotal Counter, friSStatsResetConfPktOutTotal Counter, friSStatsRestartReqPktInTotal Counter, friSStatsRestartReqPktOutTotal Counter, friSStatsRestartConfPktInTotal Counter, friSStatsRestartConfPktOutTotal Counter } friSPktSummStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500friSPacketSummaryStatsEntry 1 } friSPktSummStatsStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI station." ::= { cdx6500friSPacketSummaryStatsEntry 2 } friSStatsDataPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Data packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 3 } friSStatsDataPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Data packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 4 } friSStatsRRPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RR packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 5 } friSStatsRRPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RR packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 6 } friSStatsRNRPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RNR packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 7 } friSStatsRNRPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of RNR packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 8 } friSStatsREJPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of REJ packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 9 } friSStatsREJPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of REJ packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 10 } friSStatsCallReqPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of call request packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 11 } friSStatsCallReqPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of call request packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 12 } friSStatsCallAccPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of call accept packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 13 } friSStatsCallAccPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of call accept packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 14 } friSStatsClrReqPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of clear request packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 15 } friSStatsClrReqPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of clear request packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 16 } friSStatsClrConfPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of clear confirm packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 17 } friSStatsClrConfPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of clear confirm packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 18 } friSStatsIntrReqPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of interrupt request packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 19 } friSStatsIntrReqPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of interrupt request packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 20 } friSStatsIntrConfPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of interrupt confirm packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 21 } friSStatsIntrConfPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of interrupt confirm packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 22 } friSStatsResetReqPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of reset request packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 23 } friSStatsResetReqPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of reset request packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 24 } friSStatsResetConfPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of reset confirm packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 25 } friSStatsResetConfPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of reset confirm packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 26 } friSStatsRestartReqPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of restart request packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 27 } friSStatsRestartReqPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of restart request packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 28 } friSStatsRestartConfPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of restart confirm packets received since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 29 } friSStatsRestartConfPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of restart confirm packets transmitted since last node boot or statistics reset." ::= { cdx6500friSPacketSummaryStatsEntry 30 } -- FRI Summary Statistics Table friSFRISummaryStatsTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500friSFRISummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "This table contains FRI Station FRI Summary Statistics parameters." ::= { cdx6500SPSTFRISStatsTable 6 } cdx6500friSFRISummaryStatsEntry OBJECT-TYPE SYNTAX Cdx6500friSFRISummaryStatsEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Entries in the FRI Station FRI Summary Statistics Table. NOTE : Value of all objects in this table are valid only for Bypass stations; 0 will be returned otherwise." INDEX { friSFRISummStatsPortNumber, friSFRISummStatsStnNumber } ::= { friSFRISummaryStatsTable 1 } Cdx6500friSFRISummaryStatsEntry ::= SEQUENCE { friSFRISummStatsPortNumber INTEGER, friSFRISummStatsStnNumber INTEGER, friSStatsFECNInTotal Counter, friSStatsFECNOutTotal Counter, friSStatsBECNInTotal Counter, friSStatsBECNOutTotal Counter, friSStatsDEInTotal Counter, friSStatsDEOutTotal Counter } friSFRISummStatsPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500friSFRISummaryStatsEntry 1 } friSFRISummStatsStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI station." ::= { cdx6500friSFRISummaryStatsEntry 2 } friSStatsFECNInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Forward Explicit Congestion Notification (FECN) packets received since last node boot or statistics reset." ::= { cdx6500friSFRISummaryStatsEntry 3 } friSStatsFECNOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Forward Explicit Congestion Notification (FECN) packets transmitted since last node boot or statistics reset." ::= { cdx6500friSFRISummaryStatsEntry 4 } friSStatsBECNInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Backward Explicit Congestion Notification (BECN) packets received since last node boot or statistics reset." ::= { cdx6500friSFRISummaryStatsEntry 5 } friSStatsBECNOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Backward Explicit Congestion Notification (BECN) packets transmitted since last node boot or statistics reset." ::= { cdx6500friSFRISummaryStatsEntry 6 } friSStatsDEInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Discard Eligibility (DE) packets received since last node boot or statistics reset." ::= { cdx6500friSFRISummaryStatsEntry 7 } friSStatsDEOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of Discard Eligibility (DE) packets transmitted since last node boot or statistics reset." ::= { cdx6500friSFRISummaryStatsEntry 8 } -- The FRI Port Control Table cdx6500ContFRITable OBJECT IDENTIFIER ::= { cdx6500Controls 14 } cdx6500FRIPContTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500FRIPContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Control parameters for FRI ports." ::= { cdx6500ContFRITable 1 } cdx6500FRIPContEntry OBJECT-TYPE SYNTAX Cdx6500FRIPContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each control applies to a single FRI port." INDEX { friPContPortNumber } ::= { cdx6500FRIPContTable 1 } Cdx6500FRIPContEntry ::= SEQUENCE { friPContPortNumber INTEGER, friPContPortControl INTEGER } friPContPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "Port number of the FRI port." ::= { cdx6500FRIPContEntry 1 } friPContPortControl OBJECT-TYPE SYNTAX INTEGER { boot (1), enable (2), disable (3), resetstats (4) } ACCESS write-only STATUS mandatory DESCRIPTION "Control operations for the specified FRI port. boot - Boots the FRI port enable - Enables the FRI port disable - Disables the FRI port resetstats - Resets the FRI port statistics." ::= { cdx6500FRIPContEntry 2 } -- The FRI Station Control Table cdx6500FRISContTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500FRISContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Control parameters for FRI stations." ::= { cdx6500ContFRITable 2 } cdx6500FRISContEntry OBJECT-TYPE SYNTAX Cdx6500FRISContEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "Each control applies to a single FRI station." INDEX { friSContPortNumber, friSContStnNumber } ::= { cdx6500FRISContTable 1 } Cdx6500FRISContEntry ::= SEQUENCE { friSContPortNumber INTEGER, friSContStnNumber INTEGER, friSContStnControl INTEGER } friSContPortNumber OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS not-accessible STATUS mandatory DESCRIPTION "The FRI port number corresponding to this station." ::= { cdx6500FRISContEntry 1 } friSContStnNumber OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS not-accessible STATUS mandatory DESCRIPTION "FRI station number." ::= { cdx6500FRISContEntry 2 } friSContStnControl OBJECT-TYPE SYNTAX INTEGER { boot (1), enable (2), disable (3), resetstats (4) } ACCESS write-only STATUS mandatory DESCRIPTION "Control operations for the specified FRI station. boot - Boots the FRI station enable - Enables the FRI station disable - Disables the FRI station resetstats - Resets the FRI station statistics." ::= { cdx6500FRISContEntry 3 } END