All MIBs › FRI-OPT-MIB › friSCfgCalledSubaddress
friSCfgCalledSubaddress
Module: FRI-OPT-MIB
OID (symbolic): FRI-OPT-MIB::friSCfgCalledSubaddress
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.3.9.1.45
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-write
Description: For outgoing calls, this specifies the calling subaddress IE coded as an IA5 string with type of subaddress NSAP and IA5 AFI prefix added. Incoming calls with a called subaddress of NSAP type and IA5 AFI prefix that match this configured string will connect to this station. If this parameter is blank, the corresponding IE is not sent on outgoing calls. Incoming calls without the corresponding IE can connect to this station. The valid format of this entry is: xx...xx000000 or xx...xx000000 Where: xx...xx00 represents the station number in IA5/ASCII coded hex terminated with a NUL character suffix. For example, a sub-address of 12 would be represented by the string 313200. To set the subaddress blank, set the address string to NUL only.
What is friSCfgCalledSubaddress?
Subaddress element (3 to 6 bytes, NSAP type with IA5 AFI prefix) for calls from this station; the source description says 'calling subaddress' for outgoing calls and also describes matching of incoming called subaddresses, which is inconsistent with the 'Called' in the name, so the exact role is ambiguous. A blank (NUL only) value sends no subaddress element.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.9.1.45 snmpwalk -v2c -c public <target> FRI-OPT-MIB::friSCfgCalledSubaddress
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.9.1.45.1 snmpget -v2c -c public <target> FRI-OPT-MIB::friSCfgCalledSubaddress.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.3.9.1.45.1 s <value>
Start monitoring Codex CDX-6500 Frame Relay interface/WAN access device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRI-OPT-MIB::friSCfgCalledSubaddress OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay interface/WAN access device from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.3 | cdx6500PCTStationProtocolGroup | ATM-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.3.9 | cdx6500SPCTFRIStationTable | FRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.3.9.1 | cdx6500SPCTFRIStationEntry | FRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.3.9.1.45 | friSCfgCalledSubaddress | FRI-OPT-MIB |