All MIBs › FRI-OPT-MIB › friPCfgHighSpeedElectricalInterfaceOption
friPCfgHighSpeedElectricalInterfaceOption
Module: FRI-OPT-MIB
OID (symbolic): FRI-OPT-MIB::friPCfgHighSpeedElectricalInterfaceOption
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.31.1.46
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable
What is friPCfgHighSpeedElectricalInterfaceOption?
Tells the port which cable arrangement is used on V.35/V.36/X.21 DCE ports: 'none' for a straight-through cable, 'xover' when a crossover adapter cable is used. Wrong setting typically means no signal from the attached device.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.31.1.46 snmpwalk -v2c -c public <target> FRI-OPT-MIB::friPCfgHighSpeedElectricalInterfaceOption
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.31.1.46.1 snmpget -v2c -c public <target> FRI-OPT-MIB::friPCfgHighSpeedElectricalInterfaceOption.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.1.31.1.46.1 i <value>
Start monitoring Codex CDX-6500 Frame Relay interface/WAN access device with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRI-OPT-MIB::friPCfgHighSpeedElectricalInterfaceOption OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay interface/WAN access device from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1 | cdx6500PCTPortProtocolGroup | ALC-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.1.31 | cdx6500PPCTFRIPortTable | FRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.31.1 | cdx6500PPCTFRIPortEntry | FRI-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.1.31.1.46 | friPCfgHighSpeedElectricalInterfaceOption | FRI-OPT-MIB |