FRDTE-OPT-MIB :: cdx6500frdtesX25Options

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › FRDTE-OPT-MIB › cdx6500frdtesX25Options

cdx6500frdtesX25Options

Module: FRDTE-OPT-MIB

OID (symbolic): FRDTE-OPT-MIB::cdx6500frdtesX25Options

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.3.2.1.26

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: Please use cdx6500frdtesStnX25Options, which has been added to replace this object.

What is cdx6500frdtesX25Options?

A bitmask of X.25 options for this station -- CUG (enforce closed user group checks), CAUSE (pass cause/diagnostic codes outbound), HOLD (hold calls across a link restart), INL (mark this as an inter-node link to another 6500 device), or DELAY (enable delay/path trace, requires a Release 4.xx node), summed together as needed, with NONE meaning no options. The DESCRIPTION notes this object has been superseded by cdx6500frdtesStnX25Options, so an admin should configure X.25 options through that newer object instead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.26
snmpwalk -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesX25Options

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.26.1
snmpget -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesX25Options.1

Start monitoring Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDTE-OPT-MIB::cdx6500frdtesX25Options OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3cdx6500PCTStationProtocolGroupATM-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.3.2cdx6500SPCTFRDTEStationTableFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.2.1cdx6500SPCTFRDTEStationEntryFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.2.1.26cdx6500frdtesX25OptionsFRDTE-OPT-MIB