-- Version 2.15.1.1, modified 2001-05-31 17:27:56-04 FRDTE-OPT-MIB DEFINITIONS ::= BEGIN IMPORTS mgmt, NetworkAddress, IpAddress, Counter, Gauge, TimeTicks, enterprises FROM RFC1155-SMI OBJECT-TYPE FROM RFC-1212; -- Codex MIB Group definitions codex OBJECT IDENTIFIER ::= { enterprises 449 } cdxProductSpecific OBJECT IDENTIFIER ::= { codex 2 } cdx6500 OBJECT IDENTIFIER ::= { cdxProductSpecific 1 } cdx6500Configuration OBJECT IDENTIFIER ::= { cdx6500 2 } cdx6500CfgProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Configuration 1 } cdx6500PCTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 1 } cdx6500PCTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500CfgProtocolGroup 3 } cdx6500Statistics OBJECT IDENTIFIER ::= { cdx6500 3 } cdx6500StatProtocolGroup OBJECT IDENTIFIER ::= { cdx6500Statistics 1 } cdx6500PSTPortProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 1 } cdx6500PSTStationProtocolGroup OBJECT IDENTIFIER ::= { cdx6500StatProtocolGroup 3 } cdx6500Controls OBJECT IDENTIFIER ::= { cdx6500 4 } -- Textual conventions Counter16 ::= INTEGER (0..65535) DisplayString ::= OCTET STRING -- This data type is used to model textual information taken -- from the NVT ASCII character set. By convention, objects -- with this syntax are declared as having SIZE (0..255) -- The Frame Relay DTE Port Configuration Table -- This table contains Configuration paramaters -- for the Frame Relay DTE Port table. cdx6500PCTFRDTEPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PCTFRDTEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Frame Relay DTE Port table." ::= { cdx6500PCTPortProtocolGroup 5 } cdx6500PCTFRDTEPortEntry OBJECT-TYPE SYNTAX Cdx6500PCTFRDTEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of FRI Port configuration parameters." INDEX { cdx6500frdtepCfgPortNum } ::= { cdx6500PCTFRDTEPortTable 1 } Cdx6500PCTFRDTEPortEntry ::= SEQUENCE { cdx6500frdtepCfgPortNum INTEGER, cdx6500frdtepConnectionType INTEGER, cdx6500frdtepClockSource INTEGER, cdx6500frdtepClockSpeed INTEGER, cdx6500frdtepMaxStations INTEGER, cdx6500frdtepFrameSeqCounting INTEGER, cdx6500frdtepPktSeqCounting INTEGER, cdx6500frdtepCtrlProtocol INTEGER, cdx6500frdtepT391 INTEGER, cdx6500frdtepT392 INTEGER, cdx6500frdtepN391 INTEGER, cdx6500frdtepN392 INTEGER, cdx6500frdtepN393 INTEGER, cdx6500frdtepNT1 INTEGER, cdx6500frdtepNT2 INTEGER, cdx6500frdtepNN1 INTEGER, cdx6500frdtepNN2 INTEGER, cdx6500frdtepNN3 INTEGER, cdx6500frdtepHighPriorityStn INTEGER, cdx6500frdtepMaxVoiceBWBitsPerSec INTEGER, cdx6500frdtepSegSizeVoicePresent INTEGER, cdx6500frdtepSegSizeVoiceNotPresent INTEGER, cdx6500frdtepInvertTXClock INTEGER, cdx6500frdtepControlProtocolOptions DisplayString, cdx6500frdtepDiscardControlOptions INTEGER, cdx6500frdtepElectricalInterfaceType INTEGER, cdx6500frdtepV24ElectricalInterfaceOption INTEGER, cdx6500frdtepHighSpeedElectricalInterfaceOption INTEGER } cdx6500frdtepCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the Port number for the Frame Relay Interface port you are selecting." ::= { cdx6500PCTFRDTEPortEntry 1 } cdx6500frdtepConnectionType OBJECT-TYPE SYNTAX INTEGER { simp (1), dtr (2), simpb (21), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the control signal handshake and clocking required for a connection to be made to this port: simp - simple, no control signals required dtr - dedicated, require the data terminal ready signal (DTR) simpb - simple, no control signals required for data transmission and reception. By default output leads will be low. nc - Skipped during configuration." ::= { cdx6500PCTFRDTEPortEntry 2 } cdx6500frdtepClockSource OBJECT-TYPE SYNTAX INTEGER { int (1), ext (2), extint (3), extlp (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "int - internal clock source ext - external clock source extint - Internal receive and external transmit clock source (DCE only). extlp - external receive and loopback transmit clock source (DTE only). EXTLP must be configured in conjunction with EXTINT. nc - Skipped during configuration." ::= { cdx6500PCTFRDTEPortEntry 3 } cdx6500frdtepClockSpeed OBJECT-TYPE SYNTAX INTEGER (1200..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "This is the speed of the port in bits per second, when using internal clocking. The highest available speed is dependent on the card type,and on the interface type." ::= { cdx6500PCTFRDTEPortEntry 4 } cdx6500frdtepMaxStations OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "This is the highest station number to be configured on this FRI port. It is used to limit the configuration of stations." ::= { cdx6500PCTFRDTEPortEntry 5 } cdx6500frdtepFrameSeqCounting OBJECT-TYPE SYNTAX INTEGER { normal (1), extended (2), nc (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Port uses normal or extended frame sequence numbering: normal - normal sequencing (modulo 8) ext - extended sequencing (modulo 128) nc - Skipped during configuration. All stations on this port will be set to this value." ::= { cdx6500PCTFRDTEPortEntry 6 } cdx6500frdtepPktSeqCounting OBJECT-TYPE SYNTAX INTEGER { normal (1), extended (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Port uses normal or extended packet level sequence numbers normal - normal sequencing (Modulo 8) ext - extended sequencing (Modulo 128) nc - Skipped during configuration. This parameter must be set to the same value at both this FRI port and the remote FRI port. All stations on this port will be set to this value." ::= { cdx6500PCTFRDTEPortEntry 7 } cdx6500frdtepCtrlProtocol OBJECT-TYPE SYNTAX INTEGER { annexD (1), none (2), lmi (3), annexA (4), auto (5), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Whether ANSI T1.617 Annex D or LMI Support is enabled none - None is enabled. annexD - Annex D is enabled lmi - LMI is enabled. annexA - Annex A is enabled. auto - Auto-learn the Network control protocol type nc - Skipped during configuration." ::= { cdx6500PCTFRDTEPortEntry 8 } cdx6500frdtepT391 OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds." -- DEFVAL { 10 } ::= { cdx6500PCTFRDTEPortEntry 9 } cdx6500frdtepT392 OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode." -- DEFVAL { 15 } ::= { cdx6500PCTFRDTEPortEntry 10 } cdx6500frdtepN391 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls." -- DEFVAL { 5 } ::= { cdx6500PCTFRDTEPortEntry 12 } cdx6500frdtepN392 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3." -- DEFVAL { 5 } ::= { cdx6500PCTFRDTEPortEntry 13 } cdx6500frdtepN393 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3." -- DEFVAL { 4 } ::= { cdx6500PCTFRDTEPortEntry 14 } cdx6500frdtepNT1 OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is the Link Integrity Verification Timer polling period. The FRI port sends status enquiry messages to network every T391/nT1 seconds." -- DEFVAL { 10 } ::= { cdx6500PCTFRDTEPortEntry 15 } cdx6500frdtepNT2 OBJECT-TYPE SYNTAX INTEGER (5..30) ACCESS read-only STATUS mandatory DESCRIPTION "This parameter is the polling Cycle Verification Timer period. The FRI port expects status enquiry messages every T392/nT2 seconds. This parameter must be set to a value greater than N391/nT1, and applies only in bi-directional mode." -- DEFVAL { 15 } ::= { cdx6500PCTFRDTEPortEntry 16 } cdx6500frdtepNN1 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Full Status polling cycle. FRI port sends Full status enquiry messages to network every nN1 polls." -- DEFVAL { 5 } ::= { cdx6500PCTFRDTEPortEntry 17 } cdx6500frdtepNN2 OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Error inactivity threshold. Number of errors during NN3 events that cause the station to be declared inactive. Should be less than or equal to nN3." -- DEFVAL { 3 } ::= { cdx6500PCTFRDTEPortEntry 18 } cdx6500frdtepNN3 OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Monitored events count for measuring nN3. nN2 errors during nN3 events will cause the station to be declared inactive. Should be greater than nN3." -- DEFVAL { 4 } ::= { cdx6500PCTFRDTEPortEntry 19 } cdx6500frdtepHighPriorityStn OBJECT-TYPE SYNTAX INTEGER (1..254) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this DLCI inactive, an alternate connection over a backup link is attempted." ::= { cdx6500PCTFRDTEPortEntry 20 } cdx6500frdtepMaxVoiceBWBitsPerSec OBJECT-TYPE SYNTAX INTEGER (0..2048000) ACCESS read-write STATUS mandatory DESCRIPTION "This parameter limits the bandwidth, in bits per sec (including overhead), for voice traffic passing through this frame relay port. A zero value disables any voice passing through this port." -- DEFVAL { 2048000 } ::= { cdx6500PCTFRDTEPortEntry 21 } cdx6500frdtepSegSizeVoicePresent OBJECT-TYPE SYNTAX INTEGER { segSize32 (33), segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Data packets to be segmented into this maximum frame size when voice is active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments nc - Skipped during configuration." -- DEFVAL { segSize64 } ::= { cdx6500PCTFRDTEPortEntry 22 } cdx6500frdtepSegSizeVoiceNotPresent OBJECT-TYPE SYNTAX INTEGER { segSize32 (33), segSize64 (65), segSize128 (129), segSize256 (257), segSize512 (513), segSize1024 (1025), segSize2048 (2049), segSize4096 (4097), disable (32000), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Data packets to be segmented into this maximum frame size when voice is not active on this port. segSize32 - 32 byte segments segSize64 - 64 byte segments segSize128 - 128 byte segments segSize256 - 256 byte segments segSize512 - 512 byte segments segSize1024 - 1024 byte segments segSize2048 - 2048 byte segments segSize4096 - 4096 byte segments disable - segment size is 32768 bytes nc - Skipped during configuration." -- DEFVAL { disable } ::= { cdx6500PCTFRDTEPortEntry 23 } cdx6500frdtepInvertTXClock OBJECT-TYPE SYNTAX INTEGER { no (1), yes (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter specifies whether the phase of the transmit clock should be inverted. Note: This parameter is primarily for X.21 electrical interfaces. no - Don't invert. yes - Invert." -- DEFVAL { no } ::= { cdx6500PCTFRDTEPortEntry 24 } cdx6500frdtepControlProtocolOptions OBJECT-TYPE SYNTAX DisplayString (SIZE(0..16)) ACCESS read-write STATUS mandatory DESCRIPTION "These options control the PVC management protocol none - No option selected async - The port will send/receive asynchronous A-bit if it is performing Network side protocol functionality nbit - The port will send and accept N-bit messages dbit - The port will send and accept D-bit messages This forces ASYNC to be specified (dbit+async)" ::= { cdx6500PCTFRDTEPortEntry 25 } cdx6500frdtepDiscardControlOptions OBJECT-TYPE SYNTAX INTEGER { none (1), debit (2) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the discard frame options none - No option selected debit - DE marked frames are discarded before non-DE frames" -- DEFVAL { none } ::= { cdx6500PCTFRDTEPortEntry 26 } cdx6500frdtepElectricalInterfaceType OBJECT-TYPE SYNTAX INTEGER { v24 (1), v35 (2), v36 (3), x21 (4), none (5) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Electrical Interface Type: V.24 - V.24 Electrical Interface Type V.35 - V.35 Electrical Interface Type V.36 - V.36 Electrical Interface Type X.21 - X.21 Electrical Interface Type NONE - Electrically disabled" ::= { cdx6500PCTFRDTEPortEntry 27 } cdx6500frdtepV24ElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { ri (1), tm (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the Pin 22 option: RI - V.24 uses Pin 22 for Ring Indicator output signal TM - V.24 uses Pin 22 for Test Mode input signal" ::= { cdx6500PCTFRDTEPortEntry 28 } cdx6500frdtepHighSpeedElectricalInterfaceOption OBJECT-TYPE SYNTAX INTEGER { none (1), xover (2) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the cable type: NONE - V.35/V.36/X.21 DCE with straight through cable XOVER - V.35/V.36/X.21 DCE with crossover adapter cable" ::= { cdx6500PCTFRDTEPortEntry 29 } -- The Frame Relay DTE Port Statistics Table -- This table contains Statistics paramaters -- for the Frame Relay DTE Port table. cdx6500PPSTFRDTEPortTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500PPSTFRDTEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the Frame Relay DTE Port table." ::= { cdx6500PSTPortProtocolGroup 5 } cdx6500PPSTFRDTEPortEntry OBJECT-TYPE SYNTAX Cdx6500PPSTFRDTEPortEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Frame Relay DTE Port statistics parameters." INDEX { cdx6500frdtepStatsPortNum } ::= { cdx6500PPSTFRDTEPortTable 1 } Cdx6500PPSTFRDTEPortEntry ::= SEQUENCE { cdx6500frdtepStatsPortNum INTEGER, cdx6500frdtepPortStatus INTEGER, cdx6500frdtepPortSpeed INTEGER, cdx6500frdtepUtilizationIn INTEGER, cdx6500frdtepUtilizationOut INTEGER, cdx6500frdtepCharInTotal Counter, cdx6500frdtepCharOutTotal Counter, cdx6500frdtepCharsInPerSec INTEGER, cdx6500frdtepCharsOutPerSec INTEGER, cdx6500frdtepFrameInTotal Counter, cdx6500frdtepFrameOutTotal Counter, cdx6500frdtepFramesInPerSec INTEGER, cdx6500frdtepFramesOutPerSec INTEGER, cdx6500frdtepOverrunErrors Counter16, cdx6500frdtepUnderrunErrors Counter16, cdx6500frdtepCRCErrors Counter16 } cdx6500frdtepStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a specific port in the network diagram." ::= { cdx6500PPSTFRDTEPortEntry 1 } cdx6500frdtepPortStatus OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), busyOut (3), up (4), down (5), na (100) } ACCESS read-only STATUS mandatory DESCRIPTION "Specifies the current port status. disabled - Port has been disabled. enabled - Port is operational. busyOut - Port has been busied out. up - Port is operational. down - Port is down. na - Value not Available." ::= { cdx6500PPSTFRDTEPortEntry 2 } cdx6500frdtepPortSpeed OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Message transmition speed in bps." ::= { cdx6500PPSTFRDTEPortEntry 3 } cdx6500frdtepUtilizationIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Factor determined by comparison of volume (characters per second) of data and clock rate for a specific port." ::= { cdx6500PPSTFRDTEPortEntry 4 } cdx6500frdtepUtilizationOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Factor determined by comparison of volume (characters per second) of data and clock rate for a specific port." ::= { cdx6500PPSTFRDTEPortEntry 5 } cdx6500frdtepCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received since last boot or statistics reset." ::= { cdx6500PPSTFRDTEPortEntry 6 } cdx6500frdtepCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters transmitted since last boot or statistics reset." ::= { cdx6500PPSTFRDTEPortEntry 7 } cdx6500frdtepCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second." ::= { cdx6500PPSTFRDTEPortEntry 8 } cdx6500frdtepCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters transmitted per second." ::= { cdx6500PPSTFRDTEPortEntry 9 } cdx6500frdtepFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last boot or statistics reset." ::= { cdx6500PPSTFRDTEPortEntry 10 } cdx6500frdtepFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted since last boot or statistics reset." ::= { cdx6500PPSTFRDTEPortEntry 11 } cdx6500frdtepFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second." ::= { cdx6500PPSTFRDTEPortEntry 12 } cdx6500frdtepFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames transmitted per second." ::= { cdx6500PPSTFRDTEPortEntry 13 } cdx6500frdtepOverrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "An input buffer overflowed and characters were discarded." ::= { cdx6500PPSTFRDTEPortEntry 14 } cdx6500frdtepUnderrunErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of errors detected since last node boot or reset of statistics." ::= { cdx6500PPSTFRDTEPortEntry 15 } cdx6500frdtepCRCErrors OBJECT-TYPE SYNTAX Counter16 ACCESS read-only STATUS mandatory DESCRIPTION "Number of errors detected by Cyclic Redundancy Check since last node boot reset of statistics." ::= { cdx6500PPSTFRDTEPortEntry 16 } -- The Frame Relay DTE Station Configuration Table -- This table contains Configuration paramaters -- for the Frame Relay DTE Station table. cdx6500SPCTFRDTEStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPCTFRDTEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the configuration parameters relevant to the Frame Relay DTE Station table." ::= { cdx6500PCTStationProtocolGroup 2 } cdx6500SPCTFRDTEStationEntry OBJECT-TYPE SYNTAX Cdx6500SPCTFRDTEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Frame Realy DTE station configuration parameters." INDEX { cdx6500frdtesCfgPortNum, cdx6500frdtesCfgStationNum } ::= { cdx6500SPCTFRDTEStationTable 1 } Cdx6500SPCTFRDTEStationEntry ::= SEQUENCE { cdx6500frdtesCfgPortNum INTEGER, cdx6500frdtesCfgDLCI INTEGER, cdx6500frdtesStationType INTEGER, cdx6500frdtesCommInfoRate INTEGER, cdx6500frdtesCommBurstSize INTEGER, cdx6500frdtesTransDelay INTEGER, cdx6500frdtesControlledMode INTEGER, cdx6500frdtesLinkAddress INTEGER, cdx6500frdtesPVCChannels INTEGER, cdx6500frdtesStartingPVC INTEGER, cdx6500frdtesSVCChannels INTEGER, cdx6500frdtesStartingSVC INTEGER, cdx6500frdtesInitialFrame INTEGER, cdx6500frdtesRetryTimer INTEGER, cdx6500frdtesPollTimer INTEGER, cdx6500frdtesTries INTEGER, cdx6500frdtesFrameWinSize INTEGER, cdx6500frdtesPacketWinSize INTEGER, cdx6500frdtesMaxPacketSize INTEGER, cdx6500frdtesUpperQueue INTEGER, cdx6500frdtesLowerQueue INTEGER, cdx6500frdtesRestartTimer INTEGER, cdx6500frdtesResetTimer INTEGER, cdx6500frdtesCallTimer INTEGER, cdx6500frdtesClearTimer INTEGER, cdx6500frdtesX25Options INTEGER, cdx6500frdtesRCDestination DisplayString, cdx6500frdtesCUG DisplayString, cdx6500frdtesBillingRecords INTEGER, cdx6500frdtesCfgStationNum INTEGER, cdx6500frdtesStnX25Options DisplayString, cdx6500frdtesStnFrameSegmenter INTEGER, cdx6500frdtesStnVoiceSVCChannels INTEGER, cdx6500frdtesStnVoiceCongCtrlMode INTEGER, cdx6500frdtesStnPeakUtilization INTEGER, cdx6500frdtesStnMaxInboundQueue INTEGER, cdx6500frdtesStnAnnexGRateReduction INTEGER } cdx6500frdtesCfgPortNum OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "FR DTE Port number." ::= { cdx6500SPCTFRDTEStationEntry 1 } cdx6500frdtesCfgDLCI OBJECT-TYPE SYNTAX INTEGER (16..1007) ACCESS read-write STATUS mandatory DESCRIPTION "The Data Link Connection Identifier (dlci) is the unique identifier for the station on the FRI Port. Its valid range is 16 - 1007. It must match the DLCI configured on the FR Networking Node." ::= { cdx6500SPCTFRDTEStationEntry 2 } cdx6500frdtesStationType OBJECT-TYPE SYNTAX INTEGER { annexG (1), bypass (2), voiceRelay (3) } ACCESS read-write STATUS mandatory DESCRIPTION "Identifies the type of station being configured. annexG - This station uses X.25 signaling for layer 3 bypass - This station type bypasses layer 3. There is no signaling for SVC's on this station. voiceRelay - Not used in the current version." ::= { cdx6500SPCTFRDTEStationEntry 3 } cdx6500frdtesCommInfoRate OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter (CIR) specifies the rate (in bits-per-second) that the Frame Relay network agrees to transfer information under congested conditions for the FRI Station. This value is used to throttle data on the FRI station for congestion control purposes. The CIR cannot be greater than the link speed." ::= { cdx6500SPCTFRDTEStationEntry 4 } cdx6500frdtesCommBurstSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter (BC) specifies the maximum amount of data (in bits) that the Frame Relay network agrees to transfer over a time interval T = Committed Burst Size / Committed Information Rate. Must be > 1/20th of the Committed Information Rate. This is used for congestion control purposes." ::= { cdx6500SPCTFRDTEStationEntry 5 } cdx6500frdtesTransDelay OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This parameter is the expected one-way delay through the network. This is specified in milliseconds." ::= { cdx6500SPCTFRDTEStationEntry 6 } cdx6500frdtesControlledMode OBJECT-TYPE SYNTAX INTEGER { normal (1), disable (2), congested (3), limit (4), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the method of congestion control: normal - congestion control is normal disable - never enter Congested State (CTRL) congested - never enter a Non-Congested State (UCTRL) limit - congestion control is normal but limits the data rate to no lower than CIR. nc - Skipped during configuration" ::= { cdx6500SPCTFRDTEStationEntry 7 } cdx6500frdtesLinkAddress OBJECT-TYPE SYNTAX INTEGER { dte (1), dce (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "The logical link address must be set to complementary values in this FRI station and its corresponding remote FRI station: dte - station to have logical DTE address (A) dce - station to have logical DCE address (B) nc - Skipped during configuration." ::= { cdx6500SPCTFRDTEStationEntry 8 } cdx6500frdtesPVCChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table." ::= { cdx6500SPCTFRDTEStationEntry 9 } cdx6500frdtesStartingPVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Permanent Virtual Circuits on this FRI station. Not used if the number of PVCs = 0." ::= { cdx6500SPCTFRDTEStationEntry 10 } cdx6500frdtesSVCChannels OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical channels used in Switched Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs." ::= { cdx6500SPCTFRDTEStationEntry 11 } cdx6500frdtesStartingSVC OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the starting logical channel number for the Switched Virtual Circuits on this station (logical link). Not used if the number of SVCs = 0." ::= { cdx6500SPCTFRDTEStationEntry 12 } cdx6500frdtesInitialFrame OBJECT-TYPE SYNTAX INTEGER { sabm (1), disc (2), none (3), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Specify the initial frame required by other end for (logical) link startup: none - do nothing (other end initiates link-up) sabm - send SABM disc - send DISC, then SABM nc - Skipped during configuration" ::= { cdx6500SPCTFRDTEStationEntry 13 } cdx6500frdtesRetryTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "T1 link retry timer value in tenths of a second (e.g. 30 = 3.0 seconds)." ::= { cdx6500SPCTFRDTEStationEntry 14 } cdx6500frdtesPollTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This sets the time an idle link is probed for assurance of connection to the remote FRI station. 0 - disable the timer X - X is in tenths of a second (e.g. 40 = 4.0 seconds) and must be set greater than T1." ::= { cdx6500SPCTFRDTEStationEntry 15 } cdx6500frdtesTries OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "The maximum number of attempts allowed to complete a transmission." ::= { cdx6500SPCTFRDTEStationEntry 16 } cdx6500frdtesFrameWinSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Frame level window size must be set to the same value at both this FRI station and the remote FRI station." ::= { cdx6500SPCTFRDTEStationEntry 17 } cdx6500frdtesPacketWinSize OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Packet level window size must be set to the same value at both this FRI station and the remote FRI station." ::= { cdx6500SPCTFRDTEStationEntry 18 } cdx6500frdtesMaxPacketSize OBJECT-TYPE SYNTAX INTEGER { psize32 (6), psize64 (7), psize128 (8), psize256 (9), psize512 (10), psize1024 (11), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum X.25 packet size used on the station (logical link). For proper operation, this must be set to the same value at both this FRI station and the remote FRI station. nc - Skipped during configuration. " ::= { cdx6500SPCTFRDTEStationEntry 19 } cdx6500frdtesUpperQueue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the maximum number of data packets a channel on this station (logical link) will queue for transmission before invoking flow control to the attached channel" ::= { cdx6500SPCTFRDTEStationEntry 20 } cdx6500frdtesLowerQueue OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "This is the number of data packets a channel on this FRI station will have queued for transmission when it releases flow control to the attached channel" ::= { cdx6500SPCTFRDTEStationEntry 21 } cdx6500frdtesRestartTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Restart-Request timeout timer in seconds. If timer expires on this FRI station, the Restart request is sent again." ::= { cdx6500SPCTFRDTEStationEntry 22 } cdx6500frdtesResetTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Reset-Request timeout timer in seconds. If timer expires on this FRI station, the Reset request is sent again." ::= { cdx6500SPCTFRDTEStationEntry 23 } cdx6500frdtesCallTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Call-Request timeout timer in seconds. If timer expires on this FRI station, the call is cleared." ::= { cdx6500SPCTFRDTEStationEntry 24 } cdx6500frdtesClearTimer OBJECT-TYPE SYNTAX INTEGER ACCESS read-write STATUS mandatory DESCRIPTION "Clear-Request timeout timer in seconds. If timer expires on this FRI station, the Clear request is sent again." ::= { cdx6500SPCTFRDTEStationEntry 25 } cdx6500frdtesX25Options OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS deprecated DESCRIPTION "Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: Please use cdx6500frdtesStnX25Options, which has been added to replace this object." ::= { cdx6500SPCTFRDTEStationEntry 26 } cdx6500frdtesRCDestination OBJECT-TYPE SYNTAX DisplayString (SIZE(0..255)) ACCESS read-write STATUS mandatory DESCRIPTION "All calls entering this station will be routed to the destination specified in this parameter, irrespective of route selection table entries. For example, to route all calls to X.25 port 3, use X25-3. To route calls to FRI port 2, station 4, use FRI-2S4. Blank this field to disable this function." ::= { cdx6500SPCTFRDTEStationEntry 27 } cdx6500frdtesCUG OBJECT-TYPE SYNTAX DisplayString (SIZE(0..23)) ACCESS read-write STATUS mandatory DESCRIPTION "The station may be a member of up to 8 different Closed User Groups (CUGs). Each CUG membership must be a two digit number and separated by a comma. (e.g. 12,34,56,09,02,03 ). Two hyphens following each oher indicates no CUG Membership 00-99 - CUG Membership" ::= { cdx6500SPCTFRDTEStationEntry 28 } cdx6500frdtesBillingRecords OBJECT-TYPE SYNTAX INTEGER { off (1), on (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This controls whether billing (accounting) records will be created for calls on this FRI station. off - Billing records will not be created. on - Billing records will be created. nc - Skipped during configuration." ::= { cdx6500SPCTFRDTEStationEntry 29 } cdx6500frdtesCfgStationNum OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of the logical link on the line. This is the value of Sxx for routing purposes." ::= { cdx6500SPCTFRDTEStationEntry 30 } cdx6500frdtesStnX25Options OBJECT-TYPE SYNTAX DisplayString (SIZE(0..24)) ACCESS read-write STATUS mandatory DESCRIPTION "Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: This object has been added to replace cdx6500frdtesX25Options." ::= { cdx6500SPCTFRDTEStationEntry 31 } cdx6500frdtesStnFrameSegmenter OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "Determine if this station will support the Frame Segmenter Header.The Frame Segmenter should be enabled if the frame relay port is configured to pass voice traffic. disabled - Frame Segmenter disabled. enabled - Frame Segmenter enabled. nc - Skipped during configuration." -- DEFVAL { disabled } ::= { cdx6500SPCTFRDTEStationEntry 32 } cdx6500frdtesStnVoiceSVCChannels OBJECT-TYPE SYNTAX INTEGER (0..15) ACCESS read-write STATUS mandatory DESCRIPTION "Number of logical voice channels used in Switched Virtual Circuits.The total number of voice and data channels on a station (logical link) should be kept as small as possible and consistent with needs." -- DEFVAL { 0 } ::= { cdx6500SPCTFRDTEStationEntry 33 } cdx6500frdtesStnVoiceCongCtrlMode OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station operates normally Use this parameter in voice applications, when the frame relay network can have more than 140ms of data buffered. One typical application is asymmetrical speeds. When this parameter is enabled, and voice is detected, delta T is forced to 50 ms and the BC is forced to 1/20 CIR." -- DEFVAL { disabled } ::= { cdx6500SPCTFRDTEStationEntry 34 } cdx6500frdtesStnPeakUtilization OBJECT-TYPE SYNTAX INTEGER (0..240) ACCESS read-write STATUS mandatory DESCRIPTION "The monitoring interval size specifies the time period to use when monitoring peak data link/CIR (Committed Information Rate) utilization. 0 - Disables this monitoring feature. 1 to 240 - The number of 64 second increments to use for the monitoring interval time period. For example: a value of 30 specifies a time duration equal to 30 * 64 seconds = 1920 seconds or 32 minutes." -- DEFVAL { 0 } ::= { cdx6500SPCTFRDTEStationEntry 35 } cdx6500frdtesStnMaxInboundQueue OBJECT-TYPE SYNTAX INTEGER (100..2500) ACCESS read-write STATUS mandatory DESCRIPTION "This specifies the maximum number of frames from the network which may be queued in a BYPASS station. A smaller value may ve choosen for applications which experience objectable delays, if due to excessive growth of the BYPASS inbound queue." -- DEFVAL { 2500 } ::= { cdx6500SPCTFRDTEStationEntry 36 } cdx6500frdtesStnAnnexGRateReduction OBJECT-TYPE SYNTAX INTEGER { disabled (1), enabled (2), nc (100) } ACCESS read-write STATUS mandatory DESCRIPTION "This parameter determines whether Annex G stations will invoke implicit congestion control when a link error is detected, reducing their transmitted information rate to 1/4 CIR. The rate will be gradually increased in the normal way as non-BECN frames are received." -- DEFVAL { enabled } ::= { cdx6500SPCTFRDTEStationEntry 37 } -- The Frame Relay DTE Station Statistics Table -- This table contains Statistics paramaters -- for the Frame Relay DTE Station table. cdx6500SPSTFRDTEStationTable OBJECT-TYPE SYNTAX SEQUENCE OF Cdx6500SPSTFRDTEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "All of the statistics parameters relevant to the Frame Relay DTE Station (DLCI) table." ::= { cdx6500PSTStationProtocolGroup 2 } cdx6500SPSTFRDTEStationEntry OBJECT-TYPE SYNTAX Cdx6500SPSTFRDTEStationEntry ACCESS not-accessible STATUS mandatory DESCRIPTION "A row of Frame Relay DTE station (DLCI) Statistics parameters." INDEX { cdx6500frdtesStatsPortNum, cdx6500frdtesStatsStationNumber } ::= { cdx6500SPSTFRDTEStationTable 1 } Cdx6500SPSTFRDTEStationEntry ::= SEQUENCE { cdx6500frdtesStatsPortNum INTEGER, cdx6500frdtesStatsDLCI INTEGER, cdx6500frdtesUtilizationIn INTEGER, cdx6500frdtesUtilizationOut INTEGER, cdx6500frdtesMaxSVCCount INTEGER, cdx6500frdtesCurrentSVCCount INTEGER, cdx6500frdtesCharInTotal Counter, cdx6500frdtesCharOutTotal Counter, cdx6500frdtesCharsInPerSec INTEGER, cdx6500frdtesCharsOutPerSec INTEGER, cdx6500frdtesPktInTotal Counter, cdx6500frdtesPktOutTotal Counter, cdx6500frdtesPktsInPerSec INTEGER, cdx6500frdtesPktsOutPerSec INTEGER, cdx6500frdtesPacketsQueued INTEGER, cdx6500frdtesFrameInTotal Counter, cdx6500frdtesFrameOutTotal Counter, cdx6500frdtesFramesInPerSec INTEGER, cdx6500frdtesFramesOutPerSec INTEGER, cdx6500frdtesInfoFramesIn Counter, cdx6500frdtesInfoFramesOut Counter, cdx6500frdtesRNRFramesIn Counter, cdx6500frdtesRNRFramesOut Counter, cdx6500frdtesRRFramesIn Counter, cdx6500frdtesRRFramesOut Counter, cdx6500frdtesREJFramesIn Counter, cdx6500frdtesREJFramesOut Counter, cdx6500frdtesDataPktsIn Counter, cdx6500frdtesDataPktsOut Counter, cdx6500frdtesResetStats INTEGER, cdx6500frdtesBoot INTEGER, cdx6500frdtesDisable INTEGER, cdx6500frdtesEnable INTEGER, cdx6500frdtesStatsStationNumber INTEGER } cdx6500frdtesStatsPortNum OBJECT-TYPE SYNTAX INTEGER (1..255) ACCESS read-only STATUS mandatory DESCRIPTION "Specifies a specific port in the network diagram." ::= { cdx6500SPSTFRDTEStationEntry 1 } cdx6500frdtesStatsDLCI OBJECT-TYPE SYNTAX INTEGER (16..1007) ACCESS read-only STATUS mandatory DESCRIPTION "Data Link Connection Identifier is the unique identifier for the station on the FRI port and must match the DLCI configured on the Frame Relay networking node." ::= { cdx6500SPSTFRDTEStationEntry 2 } cdx6500frdtesUtilizationIn OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent." ::= { cdx6500SPSTFRDTEStationEntry 3 } cdx6500frdtesUtilizationOut OBJECT-TYPE SYNTAX INTEGER (0..100) ACCESS read-only STATUS mandatory DESCRIPTION "Indicates the quantity of user bytes sent down the link expressed as a percentage of the maximum number of bytes that could have been sent." ::= { cdx6500SPSTFRDTEStationEntry 4 } cdx6500frdtesMaxSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Maximum number of SVCs available in the network." ::= { cdx6500SPSTFRDTEStationEntry 5 } cdx6500frdtesCurrentSVCCount OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of SVCs currently in use." ::= { cdx6500SPSTFRDTEStationEntry 6 } cdx6500frdtesCharInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters received since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 7 } cdx6500frdtesCharOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of characters transmitted since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 8 } cdx6500frdtesCharsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters received per second." ::= { cdx6500SPSTFRDTEStationEntry 9 } cdx6500frdtesCharsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of characters transmitted per second." ::= { cdx6500SPSTFRDTEStationEntry 10 } cdx6500frdtesPktInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets received since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 11 } cdx6500frdtesPktOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of packets transmitted since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 12 } cdx6500frdtesPktsInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of packets received per second." ::= { cdx6500SPSTFRDTEStationEntry 13 } cdx6500frdtesPktsOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of packets transmitted per second." ::= { cdx6500SPSTFRDTEStationEntry 14 } cdx6500frdtesPacketsQueued OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Current number of packets buffered since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 15 } cdx6500frdtesFrameInTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames received since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 16 } cdx6500frdtesFrameOutTotal OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Number of frames transmitted since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 17 } cdx6500frdtesFramesInPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames received per second." ::= { cdx6500SPSTFRDTEStationEntry 18 } cdx6500frdtesFramesOutPerSec OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "Average number of frames transmitted per second." ::= { cdx6500SPSTFRDTEStationEntry 19 } cdx6500frdtesInfoFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Data received since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 20 } cdx6500frdtesInfoFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Data transmitted since last node boot or statistics reset." ::= { cdx6500SPSTFRDTEStationEntry 21 } cdx6500frdtesRNRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Used by the DTE or the network to request that the data flow be stopped on a particular virtual circuit." ::= { cdx6500SPSTFRDTEStationEntry 22 } cdx6500frdtesRNRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Used by the DTE or the network to request that the data flow be stopped on a particular virtual circuit." ::= { cdx6500SPSTFRDTEStationEntry 23 } cdx6500frdtesRRFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Used to clear the RNR request." ::= { cdx6500SPSTFRDTEStationEntry 24 } cdx6500frdtesRRFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "Used to clear the RNR request." ::= { cdx6500SPSTFRDTEStationEntry 25 } cdx6500frdtesREJFramesIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error." ::= { cdx6500SPSTFRDTEStationEntry 26 } cdx6500frdtesREJFramesOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A REJ transmitted by a receiver requests retransmission of a frame, due to detection of a transmission or frame sequence error." ::= { cdx6500SPSTFRDTEStationEntry 27 } cdx6500frdtesDataPktsIn OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A packet containing user information." ::= { cdx6500SPSTFRDTEStationEntry 28 } cdx6500frdtesDataPktsOut OBJECT-TYPE SYNTAX Counter ACCESS read-only STATUS mandatory DESCRIPTION "A packet containing user information." ::= { cdx6500SPSTFRDTEStationEntry 29 } -- The Frame Relay DTE Station Control objects -- These objects provide Control parameters -- for the Frame Relay DTE Stations. cdx6500frdtesResetStats OBJECT-TYPE SYNTAX INTEGER { reset (1), noReset (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Resets the specified Frame Relay station statistics. reset - Reset station statistics. noReset - Do not reset station statistics." ::= { cdx6500SPSTFRDTEStationEntry 30 } cdx6500frdtesBoot OBJECT-TYPE SYNTAX INTEGER { boot (1), noBoot (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Boots the specified Frame Relay station. boot - Boot station. noBoot - Do not boot station." ::= { cdx6500SPSTFRDTEStationEntry 31 } cdx6500frdtesDisable OBJECT-TYPE SYNTAX INTEGER { disable (1), noDisable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Disables the specified Frame Relay station. disable - Disable station. noDisable - Do not disable station." ::= { cdx6500SPSTFRDTEStationEntry 32 } cdx6500frdtesEnable OBJECT-TYPE SYNTAX INTEGER { enable (1), noEnable (2) } ACCESS write-only STATUS mandatory DESCRIPTION "Enables the specified Frame Relay station. enable - Enable station. noEnable - Do not enable station." ::= { cdx6500SPSTFRDTEStationEntry 33 } cdx6500frdtesStatsStationNumber OBJECT-TYPE SYNTAX INTEGER ACCESS read-only STATUS mandatory DESCRIPTION "The number of the FRI Station." ::= { cdx6500SPSTFRDTEStationEntry 34 } END