FRDTE-OPT-MIB :: cdx6500frdtesStnX25Options

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › FRDTE-OPT-MIB › cdx6500frdtesStnX25Options

cdx6500frdtesStnX25Options

Module: FRDTE-OPT-MIB

OID (symbolic): FRDTE-OPT-MIB::cdx6500frdtesStnX25Options

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.3.2.1.31

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: Select X.25 options on this station (logical link) as follows: NONE - no option specified CUG - check closed user group; otherwise, CUG passes transparently CAUSE - pass cause, diagnostic, code in outbound packets HOLD - hold calls over link restart INL - inter-node link. Link goes to another 6500 device DELAY - Enable Delay and Path Trace on this link (link must be connected to Rel. 4.xx node) Any combination of above specified by summing (e.g. CUG+CAUSE+. . .). NOTE: This object has been added to replace cdx6500frdtesX25Options.

What is cdx6500frdtesStnX25Options?

A bitmask of X.25 options for this station -- CUG, CAUSE, HOLD, INL, or DELAY, summed together as needed, with NONE meaning no options -- functionally the same set as cdx6500frdtesX25Options, which this object was added to replace. An admin should configure X.25 options here going forward rather than through the older, superseded object.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.31
snmpwalk -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesStnX25Options

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.31.1
snmpget -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesStnX25Options.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.31.1 s <value>

Start monitoring Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDTE-OPT-MIB::cdx6500frdtesStnX25Options OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3cdx6500PCTStationProtocolGroupATM-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.3.2cdx6500SPCTFRDTEStationTableFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.2.1cdx6500SPCTFRDTEStationEntryFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.2.1.31cdx6500frdtesStnX25OptionsFRDTE-OPT-MIB