cdx6500frdtesStnVoiceCongCtrlMode

Module: FRDTE-OPT-MIB

OID (symbolic): FRDTE-OPT-MIB::cdx6500frdtesStnVoiceCongCtrlMode

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.3.2.1.34

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This parameter controls the method of voice congestion control: enabled - Station is forced into congestion when voice calls are detected. disabled - Station operates normally Use this parameter in voice applications, when the frame relay network can have more than 140ms of data buffered. One typical application is asymmetrical speeds. When this parameter is enabled, and voice is detected, delta T is forced to 50 ms and the BC is forced to 1/20 CIR.

What is cdx6500frdtesStnVoiceCongCtrlMode?

Controls voice-specific congestion handling: enabled forces the station into a congested state whenever voice calls are detected (setting delta T to 50 ms and Bc to 1/20 CIR), while disabled leaves the station operating normally. An admin enables this for asymmetric-speed voice applications where the network can buffer more than 140 ms of data, to protect voice quality.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.34
snmpwalk -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesStnVoiceCongCtrlMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.34.1
snmpget -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesStnVoiceCongCtrlMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.34.1 i <value>

Start monitoring Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDTE-OPT-MIB::cdx6500frdtesStnVoiceCongCtrlMode OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3cdx6500PCTStationProtocolGroupATM-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.3.2cdx6500SPCTFRDTEStationTableFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.2.1cdx6500SPCTFRDTEStationEntryFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.3.2.1.34cdx6500frdtesStnVoiceCongCtrlModeFRDTE-OPT-MIB