All MIBs › FRDTE-OPT-MIB › cdx6500frdtesPVCChannels
cdx6500frdtesPVCChannels
Module: FRDTE-OPT-MIB
OID (symbolic): FRDTE-OPT-MIB::cdx6500frdtesPVCChannels
OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Number of logical channels used for Permanent Virtual Circuits. The total number of PVC and SVC channels on a station (logical link) should be kept as small as possible and consistent with needs. PVC connections must be configured in the PVC Table.
What is cdx6500frdtesPVCChannels?
The number of logical channels reserved on this station for Permanent Virtual Circuits; the combined PVC and SVC channel count should be kept as small as practical, and individual PVCs must still be configured in the PVC table. An admin sizes this to match how many permanent circuits the station actually needs.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9 snmpwalk -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesPVCChannels
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9.1 snmpget -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtesPVCChannels.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9.1 i <value>
Start monitoring Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDTE-OPT-MIB::cdx6500frdtesPVCChannels OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.449 | codex | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2 | cdxProductSpecific | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1 | cdx6500 | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2 | cdx6500Configuration | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1 | cdx6500CfgProtocolGroup | ALC-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.3 | cdx6500PCTStationProtocolGroup | ATM-OPT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.449.2.1.2.1.3.2 | cdx6500SPCTFRDTEStationTable | FRDTE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1 | cdx6500SPCTFRDTEStationEntry | FRDTE-OPT-MIB |
| 1.3.6.1.4.1.449.2.1.2.1.3.2.1.9 | cdx6500frdtesPVCChannels | FRDTE-OPT-MIB |