FRDTE-OPT-MIB :: cdx6500frdtepHighPriorityStn

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › FRDTE-OPT-MIB › cdx6500frdtepHighPriorityStn

cdx6500frdtepHighPriorityStn

Module: FRDTE-OPT-MIB

OID (symbolic): FRDTE-OPT-MIB::cdx6500frdtepHighPriorityStn

OID (numeric): 1.3.6.1.4.1.449.2.1.2.1.1.5.1.20

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: This parameter specifies a station who's PVC status has priority over all other stations when FRI same port back up is enabled. When the network reports this DLCI inactive, an alternate connection over a backup link is attempted.

What is cdx6500frdtepHighPriorityStn?

Specifies the station (1-254) whose PVC status takes priority over all others when same-port FRI backup is enabled; if the network reports this station's DLCI inactive, the port attempts to switch to an alternate backup link connection. An admin uses this to designate the most critical circuit on the port for automatic backup failover.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.5.1.20
snmpwalk -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtepHighPriorityStn

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.449.2.1.2.1.1.5.1.20.1
snmpget -v2c -c public <target> FRDTE-OPT-MIB::cdx6500frdtepHighPriorityStn.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.449.2.1.2.1.1.5.1.20.1 i <value>

Start monitoring Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FRDTE-OPT-MIB::cdx6500frdtepHighPriorityStn OID value, configure state conditions and alerts, and monitor any Codex CDX-6500 Frame Relay access device (DTE/customer-premises side) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.449codexALC-OPT-MIB
1.3.6.1.4.1.449.2cdxProductSpecificALC-OPT-MIB
1.3.6.1.4.1.449.2.1cdx6500ALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2cdx6500ConfigurationALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1cdx6500CfgProtocolGroupALC-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1cdx6500PCTPortProtocolGroupALC-OPT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.449.2.1.2.1.1.5cdx6500PCTFRDTEPortTableFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.5.1cdx6500PCTFRDTEPortEntryFRDTE-OPT-MIB
1.3.6.1.4.1.449.2.1.2.1.1.5.1.20cdx6500frdtepHighPriorityStnFRDTE-OPT-MIB