All MIBs › FJDARY-E60 › fjdaryScuCount
fjdaryScuCount
Module: FJDARY-E60
OID (symbolic): FJDARY-E60::fjdaryScuCount
OID (numeric): 1.3.6.1.4.1.211.1.21.1.60.2.5.1
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The number of SCU's informations (regardless of their current state) present on this system.
What is fjdaryScuCount?
The number of SCUs (super capacitor units, the cache-backup power source) installed in the array, sizing the SCU table.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.60.2.5.1 snmpwalk -v2c -c public <target> FJDARY-E60::fjdaryScuCount
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.60.2.5.1.1 snmpget -v2c -c public <target> FJDARY-E60::fjdaryScuCount.1
Start monitoring Fujitsu ETERNUS disk arrays with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FJDARY-E60::fjdaryScuCount OID value, configure state conditions and alerts, and monitor any Fujitsu ETERNUS disk arrays from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.211 | fujitsu | Alert-Definition-Originator-MIB |
| 1.3.6.1.4.1.211.1 | product | CFAB-MIB |
| 1.3.6.1.4.1.211.1.21 | storage | ETERNUS-OR30-SV-MIB |
| 1.3.6.1.4.1.211.1.21.1 | nsp | ETERNUS-OR30-SV-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.211.1.21.1.60 | fjdarye60 | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.2 | fjdaryPconfig | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.2.5 | fjdaryScu | FJDARY-E60 |