All MIBs › FJDARY-E60 › fjdaryEncTempInfo
fjdaryEncTempInfo
Module: FJDARY-E60
OID (symbolic): FJDARY-E60::fjdaryEncTempInfo
OID (numeric): 1.3.6.1.4.1.211.1.21.1.60.13.4.2.1.2
Node type: OBJECT-TYPE
Type: OCTET STRING
Access: read-only
Description: The value of this object indicates the temperature information of each
enclosure.
24 hours of maximum temperature information on one hour are stored.
byte 0 byte 1 byte 2 byte 3
+------------+------------+------------+------------+
0x00| Flag | CM No | DE ID |Reserved |
+------------+------------+------------+------------+
0x04| Update Time |
+------------+------------+------------+------------+
0x08| Temp Info | Temp Info | Temp Info | Temp Info |
| (current) |(1 hour ago)|(2 hour ago)|(3 hour ago)|
+------------+------------+------------+------------+
~ ~
+------------+------------+------------+------------+
0x20| Temp Info | Reserved |
|(24hour ago)| |
+------------+------------+------------+------------+What is fjdaryEncTempInfo?
A packed binary structure holding 24 hourly maximum-temperature readings for one specific device enclosure (identified by DE ID), letting an admin spot a specific shelf running hotter than the rest rather than only seeing the array-wide figure in fjdaryMachineTempInfo.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.60.13.4.2.1.2 snmpwalk -v2c -c public <target> FJDARY-E60::fjdaryEncTempInfo
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.60.13.4.2.1.2.1 snmpget -v2c -c public <target> FJDARY-E60::fjdaryEncTempInfo.1
Start monitoring Fujitsu ETERNUS disk arrays with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FJDARY-E60::fjdaryEncTempInfo OID value, configure state conditions and alerts, and monitor any Fujitsu ETERNUS disk arrays from a single console.
OID Breakdown
Upper-level ancestors (10 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.211 | fujitsu | Alert-Definition-Originator-MIB |
| 1.3.6.1.4.1.211.1 | product | CFAB-MIB |
| 1.3.6.1.4.1.211.1.21 | storage | ETERNUS-OR30-SV-MIB |
| 1.3.6.1.4.1.211.1.21.1 | nsp | ETERNUS-OR30-SV-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.211.1.21.1.60 | fjdarye60 | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.13 | fjdarySensor | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.13.4 | fjdaryEncTemp | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.13.4.2 | fjdaryEncTempTable | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.13.4.2.1 | fjdaryEncTempEntry | FJDARY-E60 |
| 1.3.6.1.4.1.211.1.21.1.60.13.4.2.1.2 | fjdaryEncTempInfo | FJDARY-E60 |