FJDARY-E101 :: fjdaryPfrscoluInfo

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FJDARY-E101 › fjdaryPfrscoluInfo

fjdaryPfrscoluInfo

Module: FJDARY-E101

OID (symbolic): FJDARY-E101::fjdaryPfrscoluInfo

OID (numeric): 1.3.6.1.4.1.211.1.21.1.101.5.8.2.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: The value of this object indicates the OLU performance data gathered
in resource layer.
         byte 0       byte 1       byte 2       byte 3
     +------------+------------+------------+------------+
 0x00| RSC OLU#index*16 Info (16 bytes)                  |
     +------------+------------+------------+------------+
 0x10| RSC OLU#index*16+1 Info (16 bytes)                |
     +------------+------------+------------+------------+
     ~                                                   
     +------------+------------+------------+------------+
 0xf0| RSC OLU#index*16+15 Info (16 bytes)               |
     +------------+------------+------------+------------+
RSC OLU information:
         byte 0       byte 1       byte 2       byte 3
     +------------+------------+------------+------------+
 0x00| Read Response Time                                |
     +------------+------------+------------+------------+
 0x04| Write Response Time                               |
     +------------+------------+------------+------------+
 0x08| Extent Busy Count                                 |
     +------------+------------+------------+------------+
 0x0c| Reserved                                          |
     +------------+------------+------------+------------+

What is fjdaryPfrscoluInfo?

Packs per-volume read and write response-time counters and extent-busy counts for sixteen open volumes per table row. Admins pull this response-time data directly to diagnose a specific host-visible volume suffering from latency, complementing the hit-rate view from fjdaryPfcacheoluInfo.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.101.5.8.2.1.2
snmpwalk -v2c -c public <target> FJDARY-E101::fjdaryPfrscoluInfo

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.101.5.8.2.1.2.1
snmpget -v2c -c public <target> FJDARY-E101::fjdaryPfrscoluInfo.1

Start monitoring Fujitsu ETERNUS DX100 S1 / E101-series disk array with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FJDARY-E101::fjdaryPfrscoluInfo OID value, configure state conditions and alerts, and monitor any Fujitsu ETERNUS DX100 S1 / E101-series disk array from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.211fujitsuAlert-Definition-Originator-MIB
1.3.6.1.4.1.211.1productCFAB-MIB
1.3.6.1.4.1.211.1.21storageETERNUS-OR30-SV-MIB
1.3.6.1.4.1.211.1.21.1nspETERNUS-OR30-SV-MIB
Numeric OIDNameModule
1.3.6.1.4.1.211.1.21.1.101fjdarye101FJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.5fjdaryPerformanceFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.5.8fjdaryPfrscoluFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.5.8.2fjdaryPfrscoluTableFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.5.8.2.1fjdaryPfrscoluEntryFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.5.8.2.1.2fjdaryPfrscoluInfoFJDARY-E101