FJDARY-E101 :: fjdaryEncTempInfo

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › FJDARY-E101 › fjdaryEncTempInfo

fjdaryEncTempInfo

Module: FJDARY-E101

OID (symbolic): FJDARY-E101::fjdaryEncTempInfo

OID (numeric): 1.3.6.1.4.1.211.1.21.1.101.13.4.2.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: The value of this object indicates the temperature information of each
enclosure.
24 hours of maximum temperature information on one hour are stored.
         byte 0       byte 1       byte 2       byte 3
     +------------+------------+------------+------------+
 0x00| Flag       | CM No      | DE ID      |Reserved    |
     +------------+------------+------------+------------+
 0x04| Update Time                                       |
     +------------+------------+------------+------------+
 0x08| Temp Info  | Temp Info  | Temp Info  | Temp Info  |
     | (current)  |(1 hour ago)|(2 hour ago)|(3 hour ago)|
     +------------+------------+------------+------------+
     ~                                                   ~
     +------------+------------+------------+------------+
 0x20| Temp Info  | Reserved                             |
     |(24hour ago)|                                      |
     +------------+------------+------------+------------+

What is fjdaryEncTempInfo?

Packs 24 hourly maximum-temperature readings for one specific enclosure (identified by DE ID), from current back to 24 hours ago. Admins use this to pinpoint which particular shelf is running hot, e.g. due to a failing fan in that enclosure, rather than only seeing the whole-machine reading.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.101.13.4.2.1.2
snmpwalk -v2c -c public <target> FJDARY-E101::fjdaryEncTempInfo

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.211.1.21.1.101.13.4.2.1.2.1
snmpget -v2c -c public <target> FJDARY-E101::fjdaryEncTempInfo.1

Start monitoring Fujitsu ETERNUS DX100 S1 / E101-series disk array with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the FJDARY-E101::fjdaryEncTempInfo OID value, configure state conditions and alerts, and monitor any Fujitsu ETERNUS DX100 S1 / E101-series disk array from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.211fujitsuAlert-Definition-Originator-MIB
1.3.6.1.4.1.211.1productCFAB-MIB
1.3.6.1.4.1.211.1.21storageETERNUS-OR30-SV-MIB
1.3.6.1.4.1.211.1.21.1nspETERNUS-OR30-SV-MIB
Numeric OIDNameModule
1.3.6.1.4.1.211.1.21.1.101fjdarye101FJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.13fjdarySensorFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.13.4fjdaryEncTempFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.13.4.2fjdaryEncTempTableFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.13.4.2.1fjdaryEncTempEntryFJDARY-E101
1.3.6.1.4.1.211.1.21.1.101.13.4.2.1.2fjdaryEncTempInfoFJDARY-E101