F5-EM-MIB :: deviceNumber

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › F5-EM-MIB › deviceNumber

deviceNumber

Module: F5-EM-MIB

OID (symbolic): F5-EM-MIB::deviceNumber

OID (numeric): 1.3.6.1.4.1.3375.3.1.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: The number of device entries in the table.

What is deviceNumber?

This value is the count of managed device entries currently present in F5 Enterprise Manager's device table. It gives an admin a quick way to see how many devices, such as BIG-IP units, EM is currently tracking without walking the entire table. For example, a value of 42 means Enterprise Manager currently manages 42 devices.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3375.3.1.1.1
snmpwalk -v2c -c public <target> F5-EM-MIB::deviceNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3375.3.1.1.1.1
snmpget -v2c -c public <target> F5-EM-MIB::deviceNumber.1

Start monitoring F5 Enterprise Manager (centralized BIG-IP fleet management, legacy) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the F5-EM-MIB::deviceNumber OID value, configure state conditions and alerts, and monitor any F5 Enterprise Manager (centralized BIG-IP fleet management, legacy) from a single console.

How to Use in IPNetwork Monitor

Select an F5 Enterprise Manager (centralized BIG-IP fleet management, legacy) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type deviceNumber into the Find box to locate it in the OID tree, then select it and click OK. The number of device entries in the table. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count changes from its expected baseline, since that would indicate the underlying set of items changed unexpectedly. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3375f5F5-3DNS-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3375.3enterpriseManagementF5-EM-MIB
1.3.6.1.4.1.3375.3.1emDevicesF5-EM-MIB
1.3.6.1.4.1.3375.3.1.1emDeviceListF5-EM-MIB
1.3.6.1.4.1.3375.3.1.1.1deviceNumberF5-EM-MIB