All MIBs › F10-CHASSIS-MIB › chSysSfmErrorStatus
chSysSfmErrorStatus
Module: F10-CHASSIS-MIB
OID (symbolic): F10-CHASSIS-MIB::chSysSfmErrorStatus
OID (numeric): 1.3.6.1.4.1.6027.3.1.1.2.8.1.8
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The Operational status provides further condition of Switch Fabric Module card. If the chSysSfmAdminStatus is 'up', the valid state is 'ok' - the card is present and ready and the chSysSfmAdminStatus status is 'up'. If the chSysSfmAdminStatus is 'down', the error status can be as followed: 'not-available' - status not available. 'error' - the card is in error state.
What is chSysSfmErrorStatus?
Reports the error condition of the switch fabric module: ok means no problems detected, error flags a fault condition on the module, and not-available applies when the admin status is down and no error status can be determined.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6027.3.1.1.2.8.1.8 snmpwalk -v2c -c public <target> F10-CHASSIS-MIB::chSysSfmErrorStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.6027.3.1.1.2.8.1.8.1 snmpget -v2c -c public <target> F10-CHASSIS-MIB::chSysSfmErrorStatus.1
Start monitoring Dell Force10 chassis switch/router (hardware inventory/environmental) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the F10-CHASSIS-MIB::chSysSfmErrorStatus OID value, configure state conditions and alerts, and monitor any Dell Force10 chassis switch/router (hardware inventory/environmental) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.6027 | dellNet | DELL-NETWORKING-SMI |
| 1.3.6.1.4.1.6027.3 | dellNetMgmt | DELL-NETWORKING-SMI |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.6027.3.1 | f10ChassisMib | F10-CHASSIS-MIB |
| 1.3.6.1.4.1.6027.3.1.1 | f10ChassisMibObject | F10-CHASSIS-MIB |
| 1.3.6.1.4.1.6027.3.1.1.2 | chSysObjects | F10-CHASSIS-MIB |
| 1.3.6.1.4.1.6027.3.1.1.2.8 | chSysSfmTable | F10-CHASSIS-MIB |
| 1.3.6.1.4.1.6027.3.1.1.2.8.1 | chSysSfmEntry | F10-CHASSIS-MIB |
| 1.3.6.1.4.1.6027.3.1.1.2.8.1.8 | chSysSfmErrorStatus | F10-CHASSIS-MIB |