ERICSSON-ROUTER-PING-MIB :: eriRouterPingHistoryIpTargetAddress

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ERICSSON-ROUTER-PING-MIB › eriRouterPingHistoryIpTargetAddress

eriRouterPingHistoryIpTargetAddress

Module: ERICSSON-ROUTER-PING-MIB

OID (symbolic): ERICSSON-ROUTER-PING-MIB::eriRouterPingHistoryIpTargetAddress

OID (numeric): 1.3.6.1.4.1.193.218.2.46.1.2.2.1.3

Node type: OBJECT-TYPE

Type: InetAddress

Access: read-only

Description: This object reports the IP address associated with a pingCtlTargetAddress value when the destination address is specified as a DNS name. The value of this object should be a zero-length octet string when a DNS name is not specified or when a specified DNS name fails to resolve.

The address type (InetAddressType) that relates to this object is specified by the corresponding value of pingResultsIpTargetAddressType.

What is eriRouterPingHistoryIpTargetAddress?

This object reports the resolved IP address associated with a ping test's target when that target was specified as a DNS name, and is a zero-length string if no DNS name was used or resolution failed. Admins use this to confirm exactly which IP address a DNS-based ping test actually reached at the time it ran, useful when DNS resolution might change over time. A populated value here alongside a DNS-named test target confirms which specific address that name resolved to during this particular historical test run.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.218.2.46.1.2.2.1.3
snmpwalk -v2c -c public <target> ERICSSON-ROUTER-PING-MIB::eriRouterPingHistoryIpTargetAddress

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.218.2.46.1.2.2.1.3.1
snmpget -v2c -c public <target> ERICSSON-ROUTER-PING-MIB::eriRouterPingHistoryIpTargetAddress.1

Start monitoring Ericsson SmartEdge/SM/SSR router (Redback Networks heritage) (active ICMP ping tests, RTT/jitter) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERICSSON-ROUTER-PING-MIB::eriRouterPingHistoryIpTargetAddress OID value, configure state conditions and alerts, and monitor any Ericsson SmartEdge/SM/SSR router (Redback Networks heritage) (active ICMP ping tests, RTT/jitter) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.218eriRouterSMIERICSSON-ROUTER-SMI
1.3.6.1.4.1.193.218.2eriRouterMgmtERICSSON-ROUTER-SMI
Numeric OIDNameModule
1.3.6.1.4.1.193.218.2.46eriRouterPingMibERICSSON-ROUTER-PING-MIB
1.3.6.1.4.1.193.218.2.46.1eriRouterPingObjectsERICSSON-ROUTER-PING-MIB
1.3.6.1.4.1.193.218.2.46.1.2eriRouterPingResultsERICSSON-ROUTER-PING-MIB
1.3.6.1.4.1.193.218.2.46.1.2.2eriRouterPingHistoryTableERICSSON-ROUTER-PING-MIB
1.3.6.1.4.1.193.218.2.46.1.2.2.1eriRouterPingHistoryEntryERICSSON-ROUTER-PING-MIB
1.3.6.1.4.1.193.218.2.46.1.2.2.1.3eriRouterPingHistoryIpTargetAddressERICSSON-ROUTER-PING-MIB