ERICSSON-ROUTER-CPU-METER-MIB :: eriRouterCpuProcTime

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ERICSSON-ROUTER-CPU-METER-MIB › eriRouterCpuProcTime

eriRouterCpuProcTime

Module: ERICSSON-ROUTER-CPU-METER-MIB

OID (symbolic): ERICSSON-ROUTER-CPU-METER-MIB::eriRouterCpuProcTime

OID (numeric): 1.3.6.1.4.1.193.218.2.6.3.1.1.3

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The total time, in milliseconds, that has been spent in this process.

What is eriRouterCpuProcTime?

This counter reports the cumulative CPU time, in milliseconds, that the process has consumed since it started. Admins compare this value across processes to identify which one is the biggest overall consumer of CPU resources over time, not just momentarily. A process showing a value of 3600000 has consumed roughly one hour of cumulative CPU time since it began running.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.193.218.2.6.3.1.1.3
snmpwalk -v2c -c public <target> ERICSSON-ROUTER-CPU-METER-MIB::eriRouterCpuProcTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.193.218.2.6.3.1.1.3.1
snmpget -v2c -c public <target> ERICSSON-ROUTER-CPU-METER-MIB::eriRouterCpuProcTime.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> eriRouterCpuProcTime.1

Start monitoring Ericsson router platform, SmartEdge/Redback heritage (CPU utilization) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ERICSSON-ROUTER-CPU-METER-MIB::eriRouterCpuProcTime OID value, configure state conditions and alerts, and monitor any Ericsson router platform, SmartEdge/Redback heritage (CPU utilization) from a single console.

How to Use in IPNetwork Monitor

Select an Ericsson router platform, SmartEdge/Redback heritage (CPU utilization) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type eriRouterCpuProcTime into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The total time, in milliseconds, that has been spent in this process. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.193ericssonANS-COMMON-MIB
1.3.6.1.4.1.193.218eriRouterSMIERICSSON-ROUTER-SMI
1.3.6.1.4.1.193.218.2eriRouterMgmtERICSSON-ROUTER-SMI
Numeric OIDNameModule
1.3.6.1.4.1.193.218.2.6eriRouterCpuMeterMIBERICSSON-ROUTER-CPU-METER-MIB
1.3.6.1.4.1.193.218.2.6.3eriRouterCpuProcMIBObjectsERICSSON-ROUTER-CPU-METER-MIB
1.3.6.1.4.1.193.218.2.6.3.1eriRouterCpuProcTableERICSSON-ROUTER-CPU-METER-MIB
1.3.6.1.4.1.193.218.2.6.3.1.1eriRouterCpuProcEntryERICSSON-ROUTER-CPU-METER-MIB
1.3.6.1.4.1.193.218.2.6.3.1.1.3eriRouterCpuProcTimeERICSSON-ROUTER-CPU-METER-MIB