EQLGROUP-MIB :: eqlStorageGroupStatusSnapshotCount

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsEQLGROUP-MIBeqlStorageGroupStatusSnapshotCount

eqlStorageGroupStatusSnapshotCount

Module: EQLGROUP-MIB

OID (symbolic): EQLGROUP-MIB::eqlStorageGroupStatusSnapshotCount

OID (numeric): 1.3.6.1.4.1.12740.1.1.2.1.11

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This field specifies the total number of snapshots in this group.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.12740.1.1.2.1.11
snmpwalk -v2c -c public <target> EQLGROUP-MIB::eqlStorageGroupStatusSnapshotCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.12740.1.1.2.1.11.1
snmpget -v2c -c public <target> EQLGROUP-MIB::eqlStorageGroupStatusSnapshotCount.1

Start monitoring Dell EqualLogic PS-series iSCSI SAN storage array group (membership/capacity) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EQLGROUP-MIB::eqlStorageGroupStatusSnapshotCount OID value, configure state conditions and alerts, and monitor any Dell EqualLogic PS-series iSCSI SAN storage array group (membership/capacity) from a single console.

How to Use in IPNetwork Monitor

Select a Dell EqualLogic PS-series iSCSI SAN storage array as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type eqlStorageGroupStatusSnapshotCount into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the current total number of snapshots in this storage group. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the count grows well beyond what your retention policy expects, since an unexpectedly large snapshot count can silently consume storage capacity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.12740equalLogicEQUALLOGIC-SMI
Numeric OIDNameModule
1.3.6.1.4.1.12740.1eqlgroupModuleEQLGROUP-MIB
1.3.6.1.4.1.12740.1.1eqlgroupObjectsEQLGROUP-MIB
1.3.6.1.4.1.12740.1.1.2eqlStorageGroupStatusTableEQLGROUP-MIB
1.3.6.1.4.1.12740.1.1.2.1eqlStorageGroupStatusEntryEQLGROUP-MIB
1.3.6.1.4.1.12740.1.1.2.1.11eqlStorageGroupStatusSnapshotCountEQLGROUP-MIB