ENTERASYS-SERVICE-LEVEL-REPORTING-MIB :: etsysSrvcLvlSystemClockResolution

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsENTERASYS-SERVICE-LEVEL-REPORTING-MIBetsysSrvcLvlSystemClockResolution

etsysSrvcLvlSystemClockResolution

Module: ENTERASYS-SERVICE-LEVEL-REPORTING-MIB

OID (symbolic): ENTERASYS-SERVICE-LEVEL-REPORTING-MIB::etsysSrvcLvlSystemClockResolution

OID (numeric): 1.3.6.1.4.1.5624.1.2.39.1.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: etsysSrvcLvlSystemClockResolution provides the precision of the clock used for the measures . The unit is the picosecond. For example, the clock on an old Unix host might advance only once every msec, and thus have a resolution of 1 msec. So its resolution is 1,000,000,000 picosecond and the value of etsysSrvcLvlSystemClockResolution is 1000000000.

What is etsysSrvcLvlSystemClockResolution?

The precision of the device's measurement clock in picoseconds — e.g. 1,000,000,000 for a 1ms-resolution clock — telling an admin how much to trust small differences in reported delay or jitter measurements.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.39.1.1.2
snmpwalk -v2c -c public <target> ENTERASYS-SERVICE-LEVEL-REPORTING-MIB::etsysSrvcLvlSystemClockResolution

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.39.1.1.2.1
snmpget -v2c -c public <target> ENTERASYS-SERVICE-LEVEL-REPORTING-MIB::etsysSrvcLvlSystemClockResolution.1

Start monitoring Enterasys (Extreme Networks) enterprise network device (IP service level metrics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-SERVICE-LEVEL-REPORTING-MIB::etsysSrvcLvlSystemClockResolution OID value, configure state conditions and alerts, and monitor any Enterasys (Extreme Networks) enterprise network device (IP service level metrics) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.39etsysServiceLevelReportingMIBENTERASYS-SERVICE-LEVEL-REPORTING-MIB
1.3.6.1.4.1.5624.1.2.39.1etsysSrvcLvlConfigObjectsENTERASYS-SERVICE-LEVEL-REPORTING-MIB
1.3.6.1.4.1.5624.1.2.39.1.1etsysSrvcLvlSystemENTERASYS-SERVICE-LEVEL-REPORTING-MIB
1.3.6.1.4.1.5624.1.2.39.1.1.2etsysSrvcLvlSystemClockResolutionENTERASYS-SERVICE-LEVEL-REPORTING-MIB