ENTERASYS-R2MGMT-MIB :: etsysR2MgmtPowerups

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ENTERASYS-R2MGMT-MIB › etsysR2MgmtPowerups

etsysR2MgmtPowerups

Module: ENTERASYS-R2MGMT-MIB

OID (symbolic): ENTERASYS-R2MGMT-MIB::etsysR2MgmtPowerups

OID (numeric): 1.3.6.1.4.1.5624.1.2.11.1.2.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: PERSISTENT: The number of times this device was powered on. Power Ups, Management Resets and Unsolicited Resets are all mutually exclusive.

What is etsysR2MgmtPowerups?

This persistent counter tracks how many times the device has been powered on. An admin uses it, alongside etsysR2MgmtResets and etsysR2MgmtUnsolicitedResets, to distinguish clean power cycles from management-initiated reboots or unexpected crashes, since the three counters are mutually exclusive categories. For example, a high etsysR2MgmtPowerups count relative to the other two counters would suggest the device is regularly being power-cycled rather than rebooted via software.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.11.1.2.1
snmpwalk -v2c -c public <target> ENTERASYS-R2MGMT-MIB::etsysR2MgmtPowerups

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.11.1.2.1.1
snmpget -v2c -c public <target> ENTERASYS-R2MGMT-MIB::etsysR2MgmtPowerups.1

Start monitoring Enterasys RoamAbout R2 Wireless Access Point (legacy Cabletron) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-R2MGMT-MIB::etsysR2MgmtPowerups OID value, configure state conditions and alerts, and monitor any Enterasys RoamAbout R2 Wireless Access Point (legacy Cabletron) from a single console.

How to Use in IPNetwork Monitor

Select an Enterasys RoamAbout R2 Wireless Access Point (legacy Cabletron) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type etsysR2MgmtPowerups into the Find box to locate it in the OID tree, then select it and click OK. It reports pERSISTENT: The number of times this device was powered on. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.11enterasysR2MgmtMIBENTERASYS-R2MGMT-MIB
1.3.6.1.4.1.5624.1.2.11.1etsysR2MgmtObjectsENTERASYS-R2MGMT-MIB
1.3.6.1.4.1.5624.1.2.11.1.2etsysR2MgmtCountersENTERASYS-R2MGMT-MIB
1.3.6.1.4.1.5624.1.2.11.1.2.1etsysR2MgmtPowerupsENTERASYS-R2MGMT-MIB