ENTERASYS-POWER-ETHERNET-EXT-MIB :: etsysPsePortPowerLimit

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-POWER-ETHERNET-EXT-MIB › etsysPsePortPowerLimit

etsysPsePortPowerLimit

Module: ENTERASYS-POWER-ETHERNET-EXT-MIB

OID (symbolic): ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPsePortPowerLimit

OID (numeric): 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: This object sets the maximum power allowed on this port. If the port exceeds its power limit, it will be shut down. This object has effect only when its module is in realtime mode (specified by etsysPseModulePowerMode). In class mode, the power limit of a port is defined by port's class upper bound, according to the IEEE standard selected in etsysPsePortCapabilitySelect.

What is etsysPsePortPowerLimit?

This object sets the maximum power, in milliwatts, a single PoE port may draw before the port is shut down; it only takes effect when the module is in realtime power mode, since class mode instead uses the port's IEEE class upper bound. An admin lowers or raises this per-port ceiling to protect the module's overall power budget from any one device drawing excessively. For example, an admin might set this to 7000 milliwatts on a port feeding a low-power IP phone to prevent an unexpected device from overdrawing power.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1
snmpwalk -v2c -c public <target> ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPsePortPowerLimit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1.1
snmpget -v2c -c public <target> ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPsePortPowerLimit.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1.1 i <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) chassis, PoE/PoE+ capable (power budget management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPsePortPowerLimit OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) chassis, PoE/PoE+ capable (power budget management) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.50etsysPowerEthernetMibExtMIBENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1etsysPowerEthernetObjectsENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.5etsysPsePortPowerManagementENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.5.1etsysPsePortPowerManagementTableENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.5.1.1etsysPsePortPowerManagementEntryENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.5.1.1.1etsysPsePortPowerLimitENTERASYS-POWER-ETHERNET-EXT-MIB