ENTERASYS-POWER-ETHERNET-EXT-MIB :: etsysPseChassisPowerSnmpNotification

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-POWER-ETHERNET-EXT-MIB › etsysPseChassisPowerSnmpNotification

etsysPseChassisPowerSnmpNotification

Module: ENTERASYS-POWER-ETHERNET-EXT-MIB

OID (symbolic): ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerSnmpNotification

OID (numeric): 1.3.6.1.4.1.5624.1.2.50.1.1.2

Node type: OBJECT-TYPE

Type: EnabledStatus

Access: read-write

Description: The current state of the SNMP Notification functionality for Pse.

enabled (1) - The Pse will generate SNMP Notifications for potentially adverse Pse power conditions. The generation of these notifications are NOT dependant upon the state of etsysPseChassisPowerAllocationMode.

disabled (2) - The SNMP Notifications defined in this MIB will NOT be generated under any conditions.

Agents are not required to generate SNMP Notifications for conditions that exist when this object is set to enabled.

Maintaining the value of this object across agent reboots is REQUIRED.

What is etsysPseChassisPowerSnmpNotification?

This object enables or disables SNMP notifications for adverse PoE power conditions on the chassis, independent of the power allocation mode setting. An admin toggles this to receive proactive alerts, such as redundancy loss or power supply failures, without needing to poll power status manually. For example, setting this to enabled(1) means the switch will emit an etsysPseChassisPowerNonRedundant trap if the power supply loses redundancy.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.50.1.1.2
snmpwalk -v2c -c public <target> ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerSnmpNotification

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.50.1.1.2.1
snmpget -v2c -c public <target> ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerSnmpNotification.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.50.1.1.2.1 s <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) chassis, PoE/PoE+ capable (power budget management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerSnmpNotification OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) chassis, PoE/PoE+ capable (power budget management) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.50etsysPowerEthernetMibExtMIBENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1etsysPowerEthernetObjectsENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.1etsysPseChassisPowerAllocationENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.1.2etsysPseChassisPowerSnmpNotificationENTERASYS-POWER-ETHERNET-EXT-MIB