ENTERASYS-POWER-ETHERNET-EXT-MIB :: etsysPseChassisPowerAvailableMaximum

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ENTERASYS-POWER-ETHERNET-EXT-MIB › etsysPseChassisPowerAvailableMaximum

etsysPseChassisPowerAvailableMaximum

Module: ENTERASYS-POWER-ETHERNET-EXT-MIB

OID (symbolic): ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerAvailableMaximum

OID (numeric): 1.3.6.1.4.1.5624.1.2.50.1.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The maximum percentage of power from the Pse Power Supply that this chassis can use.

The default value should be 100 percent, meaning the chassis can use all the power detected from Pse Power Supply.

Maintaining the value of this object across agent reboots is REQUIRED.

What is etsysPseChassisPowerAvailableMaximum?

This object sets the maximum percentage of the detected PoE power supply capacity that the chassis is permitted to use, expressed as a percent from 0 to 100. An admin lowers this from the default of 100 to intentionally reserve a safety margin of power supply headroom, such as for future expansion or to protect against supply degradation. For example, setting this to 90 means the chassis will only draw on 90% of the power the supply reports as detected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.50.1.1.3
snmpwalk -v2c -c public <target> ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerAvailableMaximum

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5624.1.2.50.1.1.3.1
snmpget -v2c -c public <target> ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerAvailableMaximum.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5624.1.2.50.1.1.3.1 i <value>

Start monitoring Enterasys Networks switch (legacy, later Extreme Networks) chassis, PoE/PoE+ capable (power budget management) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENTERASYS-POWER-ETHERNET-EXT-MIB::etsysPseChassisPowerAvailableMaximum OID value, configure state conditions and alerts, and monitor any Enterasys Networks switch (legacy, later Extreme Networks) chassis, PoE/PoE+ capable (power budget management) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5624enterasysENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1etsysMibsENTERASYS-MIB-NAMES
1.3.6.1.4.1.5624.1.2etsysModulesENTERASYS-MIB-NAMES
Numeric OIDNameModule
1.3.6.1.4.1.5624.1.2.50etsysPowerEthernetMibExtMIBENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1etsysPowerEthernetObjectsENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.1etsysPseChassisPowerAllocationENTERASYS-POWER-ETHERNET-EXT-MIB
1.3.6.1.4.1.5624.1.2.50.1.1.3etsysPseChassisPowerAvailableMaximumENTERASYS-POWER-ETHERNET-EXT-MIB