All MIBs › ENLOGIC-PDU-MIB › pduUnitConfigOutletEnergyReset
pduUnitConfigOutletEnergyReset
Module: ENLOGIC-PDU-MIB
OID (symbolic): ENLOGIC-PDU-MIB::pduUnitConfigOutletEnergyReset
OID (numeric): 1.3.6.1.4.1.38446.1.2.2.1.17
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Setting this OID to reset (2) will cause the outlet energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not support this feature will respond to this OID with a value of notSupported (3). Attempts to set this OID in these models will fail.
What is pduUnitConfigOutletEnergyReset?
A write-only control that zeroes the energy meter on every metered outlet when set to reset(2); models that lack per-outlet resettable meters respond notSupported(3). It is used to start fresh per-outlet energy accounting, for example after reassigning equipment to different outlets.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.38446.1.2.2.1.17 snmpwalk -v2c -c public <target> ENLOGIC-PDU-MIB::pduUnitConfigOutletEnergyReset
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.38446.1.2.2.1.17.1 snmpget -v2c -c public <target> ENLOGIC-PDU-MIB::pduUnitConfigOutletEnergyReset.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.38446.1.2.2.1.17.1 i <value>
Start monitoring Enlogic intelligent Power Distribution Unit (PDU) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENLOGIC-PDU-MIB::pduUnitConfigOutletEnergyReset OID value, configure state conditions and alerts, and monitor any Enlogic intelligent Power Distribution Unit (PDU) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.38446 | enlogic | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1 | pdu | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.2 | pduUnit | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.2.2 | pduUnitConfigTable | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.2.2.1 | pduUnitConfigEntry | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.2.2.1.17 | pduUnitConfigOutletEnergyReset | ENLOGIC-PDU-MIB |