pduOutletMeteredPropertiesInputPhaseLayout

Module: ENLOGIC-PDU-MIB

OID (symbolic): ENLOGIC-PDU-MIB::pduOutletMeteredPropertiesInputPhaseLayout

OID (numeric): 1.3.6.1.4.1.38446.1.5.8.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: This OID describes the outlet phase connections on the referenced bank as follows: seqPhase1ToNeutral(1) indicates that outlets attached to Metered Outlet are connected from Phase 1 to Neutral. seqPhase2ToNeutral(2) indicates that outlets attached to Metered Outlet are connected from Phase 2 to Neutral. seqPhase3ToNeutral(3) indicates that outlets attached to Metered Outlet are connected from Phase 3 to Neutral. seqPhase1ToPhase2(4) indicates that outlets attached to Metered Outlet are connected from Phase 1 to Phase2. seqPhase2ToPhase3(5) indicates that outlets attached to Metered Outlet are connected from Phase 2 to Phase3. seqPhase3ToPhase1(6) indicates that outlets attached to Metered Outlet are connected from Phase 3 to Phase1.

What is pduOutletMeteredPropertiesInputPhaseLayout?

Describes which phase or phase-pair feeds this metered outlet, one of six values such as seqPhase2ToNeutral(2) or seqPhase1ToPhase2(4). Admins use it to decide which outlet to plug new high-draw equipment into so three-phase load stays balanced.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.38446.1.5.8.1.4
snmpwalk -v2c -c public <target> ENLOGIC-PDU-MIB::pduOutletMeteredPropertiesInputPhaseLayout

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.38446.1.5.8.1.4.1
snmpget -v2c -c public <target> ENLOGIC-PDU-MIB::pduOutletMeteredPropertiesInputPhaseLayout.1

Start monitoring Enlogic intelligent Power Distribution Unit (PDU) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENLOGIC-PDU-MIB::pduOutletMeteredPropertiesInputPhaseLayout OID value, configure state conditions and alerts, and monitor any Enlogic intelligent Power Distribution Unit (PDU) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.38446enlogicENLOGIC-PDU-MIB
1.3.6.1.4.1.38446.1pduENLOGIC-PDU-MIB
1.3.6.1.4.1.38446.1.5pduOutletENLOGIC-PDU-MIB
1.3.6.1.4.1.38446.1.5.8pduOutletMeteredPropertiesTableENLOGIC-PDU-MIB
1.3.6.1.4.1.38446.1.5.8.1pduOutletMeteredPropertiesEntryENLOGIC-PDU-MIB
1.3.6.1.4.1.38446.1.5.8.1.4pduOutletMeteredPropertiesInputPhaseLayoutENLOGIC-PDU-MIB