All MIBs › ENLOGIC-PDU-MIB › pduOutletMeteredConfigAlarmStateChangeDelay
pduOutletMeteredConfigAlarmStateChangeDelay
Module: ENLOGIC-PDU-MIB
OID (symbolic): ENLOGIC-PDU-MIB::pduOutletMeteredConfigAlarmStateChangeDelay
OID (numeric): 1.3.6.1.4.1.38446.1.5.7.1.8
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: The delay measured in samples before a state is asserted. If the value is zero, then the state is asserted as soon as it is detected; if it is non-zero, say n, then the assertion condition must exist for n+1 consecutive samples before the corresponding assertion event is reported.
What is pduOutletMeteredConfigAlarmStateChangeDelay?
The number of consecutive samples this outlet's power must remain past a threshold before the alarm is asserted; 0 means assert immediately. Admins raise it to ignore brief power blips from a device cycling a fan or disk, avoiding a false alarm.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.38446.1.5.7.1.8 snmpwalk -v2c -c public <target> ENLOGIC-PDU-MIB::pduOutletMeteredConfigAlarmStateChangeDelay
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.38446.1.5.7.1.8.1 snmpget -v2c -c public <target> ENLOGIC-PDU-MIB::pduOutletMeteredConfigAlarmStateChangeDelay.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.38446.1.5.7.1.8.1 i <value>
Start monitoring Enlogic intelligent Power Distribution Unit (PDU) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENLOGIC-PDU-MIB::pduOutletMeteredConfigAlarmStateChangeDelay OID value, configure state conditions and alerts, and monitor any Enlogic intelligent Power Distribution Unit (PDU) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.38446 | enlogic | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1 | pdu | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.5 | pduOutlet | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.5.7 | pduOutletMeteredConfigTable | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.5.7.1 | pduOutletMeteredConfigEntry | ENLOGIC-PDU-MIB |
| 1.3.6.1.4.1.38446.1.5.7.1.8 | pduOutletMeteredConfigAlarmStateChangeDelay | ENLOGIC-PDU-MIB |