ENGENIUS-MESH-MIB :: systemMemory

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ENGENIUS-MESH-MIB › systemMemory

systemMemory

Module: ENGENIUS-MESH-MIB

OID (symbolic): ENGENIUS-MESH-MIB::systemMemory

OID (numeric): 1.3.6.1.4.1.14125.1.1.1.2

Node type: OBJECT-TYPE

Type: Integer32

Access: read-only

Description: This object represent the percentage of the system free memory.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.14125.1.1.1.2
snmpwalk -v2c -c public <target> ENGENIUS-MESH-MIB::systemMemory

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.14125.1.1.1.2.1
snmpget -v2c -c public <target> ENGENIUS-MESH-MIB::systemMemory.1

Start monitoring EnGenius wireless mesh access point with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ENGENIUS-MESH-MIB::systemMemory OID value, configure state conditions and alerts, and monitor any EnGenius wireless mesh access point from a single console.

How to Use in IPNetwork Monitor

Select an EnGenius wireless mesh access point as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type systemMemory into the Find box to locate it in the OID tree, then select it and click OK. This object represent the percentage of the system free memory. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an Integer32-type OID, Value bounds is the most useful condition here — trigger an alert if the percentage drops below roughly 10-15% (this object reports percent *free*, not percent used), since that indicates the device is running low on memory. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.14125engeniusENGENIUS-CLIENT-MIB
1.3.6.1.4.1.14125.1engeniusmeshENGENIUS-CLIENT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.14125.1.1nodeStatusENGENIUS-MESH-MIB
1.3.6.1.4.1.14125.1.1.1nodeStatusSystemENGENIUS-MESH-MIB
1.3.6.1.4.1.14125.1.1.1.2systemMemoryENGENIUS-MESH-MIB