ELTEX-MES-PHYSICAL-DESCRIPTION-MIB :: eltPhdTransceiverThresholdType

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › ELTEX-MES-PHYSICAL-DESCRIPTION-MIB › eltPhdTransceiverThresholdType

eltPhdTransceiverThresholdType

Module: ELTEX-MES-PHYSICAL-DESCRIPTION-MIB

OID (symbolic): ELTEX-MES-PHYSICAL-DESCRIPTION-MIB::eltPhdTransceiverThresholdType

OID (numeric): 1.3.6.1.4.1.35265.1.23.53.1.2.1.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: A value indicating the threshold to configure. temperature - degree (Celsius) -127-127, voltage - microVolt 0-6550000, current - microAmper 0-131000, output power or input power - microWatt 0-6553

What is eltPhdTransceiverThresholdType?

This read-write enumerated object selects which transceiver diagnostic parameter a threshold entry applies to, among temperature(0) in Celsius, supply(1) voltage in microvolts, txBias(2) current in microamps, txOutput(3), or rxOpticalPower(4) in microwatts. Admins select this to specify which physical measurement the accompanying alarm/warning threshold values govern. For example, setting this to rxOpticalPower(4) means the associated high/low alarm and warning thresholds configured elsewhere will monitor the transceiver's received optical signal strength.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.53.1.2.1.1
snmpwalk -v2c -c public <target> ELTEX-MES-PHYSICAL-DESCRIPTION-MIB::eltPhdTransceiverThresholdType

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.53.1.2.1.1.1
snmpget -v2c -c public <target> ELTEX-MES-PHYSICAL-DESCRIPTION-MIB::eltPhdTransceiverThresholdType.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.35265.1.23.53.1.2.1.1.1 i <value>

Start monitoring Eltex MES-series switch (SFP/transceiver inventory) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ELTEX-MES-PHYSICAL-DESCRIPTION-MIB::eltPhdTransceiverThresholdType OID value, configure state conditions and alerts, and monitor any Eltex MES-series switch (SFP/transceiver inventory) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.35265eltexLtdELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1elHardwareELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1.23eltMesELTEX-MES
1.3.6.1.4.1.35265.1.23.53eltMesPhdTransceiverELTEX-MES
Numeric OIDNameModule
1.3.6.1.4.1.35265.1.23.53.1eltMesPhdTransceiverELTEX-MES-PHYSICAL-DESCRIPTION-MIB
1.3.6.1.4.1.35265.1.23.53.1.2eltPhdTransceiverThresholdTableELTEX-MES-PHYSICAL-DESCRIPTION-MIB
1.3.6.1.4.1.35265.1.23.53.1.2.1eltPhdTransceiverThresholdEntryELTEX-MES-PHYSICAL-DESCRIPTION-MIB
1.3.6.1.4.1.35265.1.23.53.1.2.1.1eltPhdTransceiverThresholdTypeELTEX-MES-PHYSICAL-DESCRIPTION-MIB