ELTEX-MES-L2-TUNNEL-CONFIG-MIB :: eltLtcTunnelShutdownThreshold

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › ELTEX-MES-L2-TUNNEL-CONFIG-MIB › eltLtcTunnelShutdownThreshold

eltLtcTunnelShutdownThreshold

Module: ELTEX-MES-L2-TUNNEL-CONFIG-MIB

OID (symbolic): ELTEX-MES-L2-TUNNEL-CONFIG-MIB::eltLtcTunnelShutdownThreshold

OID (numeric): 1.3.6.1.4.1.35265.1.23.13.1.3.1.1.3

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The shutdown threshold on an interface for a given protocol. After reaching the shutdown threshold, the interface will shutdown for the given protocol. This value cannot be less than the value of eltLtcTunnelDropThreshold. A value of 0 indicates that no limit is set.

What is eltLtcTunnelShutdownThreshold?

This value sets the PDU-rate shutdown threshold, for a given tunneled protocol on this interface, above which the interface shuts down for that protocol entirely; it cannot be less than eltLtcTunnelDropThreshold, and a value of 0 means no limit. Admins tune it as a stronger protective measure than the drop threshold, taking the tunneled protocol offline on that interface if the flood continues even after PDUs started being dropped. Setting it to 200 would shut down tunneling for that protocol on the interface once the PDU rate exceeds 200, a more severe reaction than merely dropping excess PDUs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.13.1.3.1.1.3
snmpwalk -v2c -c public <target> ELTEX-MES-L2-TUNNEL-CONFIG-MIB::eltLtcTunnelShutdownThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.35265.1.23.13.1.3.1.1.3.1
snmpget -v2c -c public <target> ELTEX-MES-L2-TUNNEL-CONFIG-MIB::eltLtcTunnelShutdownThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.35265.1.23.13.1.3.1.1.3.1 i <value>

Start monitoring Eltex MES-series Ethernet switch (Layer 2 protocol tunneling) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the ELTEX-MES-L2-TUNNEL-CONFIG-MIB::eltLtcTunnelShutdownThreshold OID value, configure state conditions and alerts, and monitor any Eltex MES-series Ethernet switch (Layer 2 protocol tunneling) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.35265eltexLtdELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1elHardwareELTEX-SMI-ACTUAL
1.3.6.1.4.1.35265.1.23eltMesELTEX-MES
Numeric OIDNameModule
1.3.6.1.4.1.35265.1.23.13eltMesL2TunnelConfigELTEX-MES-L2-TUNNEL-CONFIG-MIB
1.3.6.1.4.1.35265.1.23.13.1eltMesLtcMIBObjectsELTEX-MES-L2-TUNNEL-CONFIG-MIB
1.3.6.1.4.1.35265.1.23.13.1.3eltMesLtcTunnelThresholdELTEX-MES-L2-TUNNEL-CONFIG-MIB
1.3.6.1.4.1.35265.1.23.13.1.3.1eltLtcTunnelThresholdTableELTEX-MES-L2-TUNNEL-CONFIG-MIB
1.3.6.1.4.1.35265.1.23.13.1.3.1.1eltLtcTunnelThresholdEntryELTEX-MES-L2-TUNNEL-CONFIG-MIB
1.3.6.1.4.1.35265.1.23.13.1.3.1.1.3eltLtcTunnelShutdownThresholdELTEX-MES-L2-TUNNEL-CONFIG-MIB