outletControlRebootCmd

Module: EATON-EPDU-MIB

OID (symbolic): EATON-EPDU-MIB::outletControlRebootCmd

OID (numeric): 1.3.6.1.4.1.534.6.6.7.6.6.1.5

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: Outlet control command.

For outlets that are On prior to this Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets that are Off prior to the Reboot command, they will turn On after a delay of outletControlRebootOffTime seconds from when the command is issued. 0-n : Time in seconds until the Reboot command is issued -1 : Cancel a pending outlet Reboot command

When read, returns -1 if no command is pending, or the current downcount in seconds of a pending command.

Certain ePDUs (mainly those with part numbers beginning with IPV or IPC) do not support delayed control commands. These will respond with an error if a command value of > 0 is written to this object.

What is outletControlRebootCmd?

Read-write integer (-1 to 99999) issuing a reboot on this specific outlet: if it's on it switches off immediately, stays off for outletControlRebootOffTime seconds, then turns back on; if it was already off it simply turns on after that same delay. Admins use this as a remote power-cycle for a single hung device, e.g. an unresponsive server or network appliance.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.534.6.6.7.6.6.1.5
snmpwalk -v2c -c public <target> EATON-EPDU-MIB::outletControlRebootCmd

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.534.6.6.7.6.6.1.5.1
snmpget -v2c -c public <target> EATON-EPDU-MIB::outletControlRebootCmd.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.534.6.6.7.6.6.1.5.1 i <value>

Start monitoring Eaton ePDU rack power distribution unit with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the EATON-EPDU-MIB::outletControlRebootCmd OID value, configure state conditions and alerts, and monitor any Eaton ePDU rack power distribution unit from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.534eatonEATON-OIDS
1.3.6.1.4.1.534.6productsEATON-OIDS
1.3.6.1.4.1.534.6.6pduAgentEATON-OIDS
Numeric OIDNameModule
1.3.6.1.4.1.534.6.6.7eatonEpduEATON-EPDU-MIB
1.3.6.1.4.1.534.6.6.7.6outletsEATON-EPDU-MIB
1.3.6.1.4.1.534.6.6.7.6.6outletControlTableEATON-EPDU-MIB
1.3.6.1.4.1.534.6.6.7.6.6.1outletControlEntryEATON-EPDU-MIB
1.3.6.1.4.1.534.6.6.7.6.6.1.5outletControlRebootCmdEATON-EPDU-MIB