All MIBs › DeltaUPS-MIB › dupsSecondsOnBattery
dupsSecondsOnBattery
Module: DeltaUPS-MIB
OID (symbolic): DeltaUPS-MIB::dupsSecondsOnBattery
OID (numeric): 1.3.6.1.4.1.2254.2.4.7.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: If the unit is on battery power, the elapsed time since the UPS last switched to battery power, or the time since the network management subsystem was last restarted, whichever is less. Zero shall be returned if the unit is not on battery power.
What is dupsSecondsOnBattery?
Read-only integer, in seconds, giving how long the UPS has been running on battery since it last switched over (or since the agent last restarted, whichever is shorter); it reads 0 when the UPS is not on battery, so a nonzero value flags an ongoing outage.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2254.2.4.7.4 snmpwalk -v2c -c public <target> DeltaUPS-MIB::dupsSecondsOnBattery
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2254.2.4.7.4.1 snmpget -v2c -c public <target> DeltaUPS-MIB::dupsSecondsOnBattery.1
Start monitoring Delta UPS (uninterruptible power supply) system with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DeltaUPS-MIB::dupsSecondsOnBattery OID value, configure state conditions and alerts, and monitor any Delta UPS (uninterruptible power supply) system from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2254 | delta | DeltaUPS-MIB |
| 1.3.6.1.4.1.2254.2 | ups | DeltaUPS-MIB |
| 1.3.6.1.4.1.2254.2.4 | upsv4 | DeltaUPS-MIB |
| 1.3.6.1.4.1.2254.2.4.7 | dupsBattery | DeltaUPS-MIB |
| 1.3.6.1.4.1.2254.2.4.7.4 | dupsSecondsOnBattery | DeltaUPS-MIB |