DellrPDU-MIB :: rPDUOutletSwitchedControlCmd

MIB Reference — IPNetwork Monitor · Updated September 21, 2026

All MIBs › DellrPDU-MIB › rPDUOutletSwitchedControlCmd

rPDUOutletSwitchedControlCmd

Module: DellrPDU-MIB

OID (symbolic): DellrPDU-MIB::rPDUOutletSwitchedControlCmd

OID (numeric): 1.3.6.1.4.1.674.10903.200.2.200.130.1.4.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Getting this variable will return the outlet state. If the outlet is on, the outletOn (1) value will be returned. If the outlet is off, the outletOff (2) value will be returned. If the state of the outlet cannot be determined, the outletUnknown (4) value will be returned. If the outletUnknown condition should occur, all devices receiving power from the PDU should be shut down. The PDU's power should then be cycled to clear this condition. Setting this variable to outletOn (1) will turn the outlet on. Setting this variable to outletOff (2) will turn the outlet off. Setting this variable to outletReboot (3) will reboot the outlet. Setting this variable to outletOnWithDelay (5) will turn the outlet on after the rPDUOutSwitchedCfgPowerOnTime OID has elapsed. Setting this variable to outletOffWithDelay (6) will turn the outlet off after the rPDUOutSwitchedCfgPowerOffTime OID has elapsed. Setting this variable to outletRebootWithDelay (7) will turn the outlet off after the rPDUOutSwitchedCfgPowerOffTime OID has elapsed, wait the rPDUOutSwtchedCfgRebootDuration OID time, then turn the outlet back on.

What is rPDUOutletSwitchedControlCmd?

An admin writes this object to turn an individual outlet on, off, or reboot it (optionally with a configured delay); for example setting outletRebootWithDelay(7) turns the outlet off after its configured power-off delay, waits the configured reboot duration, then turns it back on, while a get reports the outlet's current on/off/unknown state.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10903.200.2.200.130.1.4.1.4
snmpwalk -v2c -c public <target> DellrPDU-MIB::rPDUOutletSwitchedControlCmd

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10903.200.2.200.130.1.4.1.4.1
snmpget -v2c -c public <target> DellrPDU-MIB::rPDUOutletSwitchedControlCmd.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.674.10903.200.2.200.130.1.4.1.4.1 i <value>

Start monitoring Dell rPDU (rack Power Distribution Unit) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DellrPDU-MIB::rPDUOutletSwitchedControlCmd OID value, configure state conditions and alerts, and monitor any Dell rPDU (rack Power Distribution Unit) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10903pduDellrPDU-MIB
1.3.6.1.4.1.674.10903.200pdusubDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2hardwareDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2.200rPDUDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2.200.130rPDUOutletDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2.200.130.1rPDUOutletSwitchedDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2.200.130.1.4rPDUOutletSwitchedControlTableDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2.200.130.1.4.1rPDUOutletSwitchedControlEntryDellrPDU-MIB
1.3.6.1.4.1.674.10903.200.2.200.130.1.4.1.4rPDUOutletSwitchedControlCmdDellrPDU-MIB