All MIBs › DVB-CABLE-INA-IF-MIB › dvbInaIfMacRespCollTimeWindow
dvbInaIfMacRespCollTimeWindow
Module: DVB-CABLE-INA-IF-MIB
OID (symbolic): DVB-CABLE-INA-IF-MIB::dvbInaIfMacRespCollTimeWindow
OID (numeric): 1.3.6.1.2.1.10.146.1.1.1.1.15
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: Specifies the maximum time for the sign-on response message transmission randomisation.
What is dvbInaIfMacRespCollTimeWindow?
The maximum time window, in milliseconds (default 900), over which NIUs randomise transmission of their sign-on response message to avoid all colliding at once. Widening it reduces upstream contention collisions during mass sign-on events (e.g. after a plant-wide reboot) at the cost of slower aggregate sign-on.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.146.1.1.1.1.15 snmpwalk -v2c -c public <target> DVB-CABLE-INA-IF-MIB::dvbInaIfMacRespCollTimeWindow
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.146.1.1.1.1.15.1 snmpget -v2c -c public <target> DVB-CABLE-INA-IF-MIB::dvbInaIfMacRespCollTimeWindow.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.10.146.1.1.1.1.15.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> dvbInaIfMacRespCollTimeWindow.1
Start monitoring DVB/DAVIC EuroModem cable Interactive Network Adapter (vendor-neutral standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DVB-CABLE-INA-IF-MIB::dvbInaIfMacRespCollTimeWindow OID value, configure state conditions and alerts, and monitor any DVB/DAVIC EuroModem cable Interactive Network Adapter (vendor-neutral standard) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.146 | dvbInaIf | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1 | dvbInaIfMIBObjects | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1 | dvbInaIfMac | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1.1 | dvbInaIfMacTable | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1.1.1 | dvbInaIfMacEntry | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1.1.1.15 | dvbInaIfMacRespCollTimeWindow | DVB-CABLE-INA-IF-MIB |