All MIBs › DVB-CABLE-INA-IF-MIB › dvbInaIfMacMaxContentionMsgLen
dvbInaIfMacMaxContentionMsgLen
Module: DVB-CABLE-INA-IF-MIB
OID (symbolic): DVB-CABLE-INA-IF-MIB::dvbInaIfMacMaxContentionMsgLen
OID (numeric): 1.3.6.1.2.1.10.146.1.1.1.1.23
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: The default value for the Maximum_Contention_Access_Message_Length in the Connect Message. This is the maximum length of a message that may be transmitted using contention access. Any message greater than this should use reservation access. See also dvbInaIfConMaxContentionMsgLen.
What is dvbInaIfMacMaxContentionMsgLen?
The default maximum message length, in ATM cells (default 1), that may be sent via contention access before the NIU must switch to reservation access instead; individual connections can override this via dvbInaIfConMaxContentionMsgLen. It caps how much upstream traffic is allowed to collide-and-retry rather than being scheduled.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.146.1.1.1.1.23 snmpwalk -v2c -c public <target> DVB-CABLE-INA-IF-MIB::dvbInaIfMacMaxContentionMsgLen
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.146.1.1.1.1.23.1 snmpget -v2c -c public <target> DVB-CABLE-INA-IF-MIB::dvbInaIfMacMaxContentionMsgLen.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.2.1.10.146.1.1.1.1.23.1 i <value>
Start monitoring DVB/DAVIC EuroModem cable Interactive Network Adapter (vendor-neutral standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DVB-CABLE-INA-IF-MIB::dvbInaIfMacMaxContentionMsgLen OID value, configure state conditions and alerts, and monitor any DVB/DAVIC EuroModem cable Interactive Network Adapter (vendor-neutral standard) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | APERTUS-NPG-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.146 | dvbInaIf | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1 | dvbInaIfMIBObjects | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1 | dvbInaIfMac | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1.1 | dvbInaIfMacTable | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1.1.1 | dvbInaIfMacEntry | DVB-CABLE-INA-IF-MIB |
| 1.3.6.1.2.1.10.146.1.1.1.1.23 | dvbInaIfMacMaxContentionMsgLen | DVB-CABLE-INA-IF-MIB |