All MIBs › DOCS-PNM-MIB › docsPnmCmtsUsOfdmaRxPwrEnable
docsPnmCmtsUsOfdmaRxPwrEnable
Module: DOCS-PNM-MIB
OID (symbolic): DOCS-PNM-MIB::docsPnmCmtsUsOfdmaRxPwrEnable
OID (numeric): 1.3.6.1.4.1.4491.2.1.27.1.3.6.1.1
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: This attribute causes the CMTS to begin a measurement of the received upstream channel power for the CM whose MAC address was specified in the CmMac attribute.
Interaction with other table rows:
- This object returns 'inconsistentValue' if set to 'true' while the value of 'docsPnmCmtsUsOfdmaRxPwrMeasStatus' is a value of 'busy'.
- Default values are provided for read-write objects in this table; thus, this object may be set to 'true' without explicitly setting these values. However, the default values may not be appropriate and care should be taken to insure these values are correct for the desired test case.
- Setting this object to a value of 'true' will change the value of the 'docsPnmCmtsUsOfdmaRxPwrMeasStatus' to 'busy'.
What is docsPnmCmtsUsOfdmaRxPwrEnable?
Setting this 'true' starts a measurement of the received upstream channel power for the CM identified in the CmMac attribute. Used to check whether a specific CM's transmit power/level is arriving at the CMTS within the expected range.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.27.1.3.6.1.1 snmpwalk -v2c -c public <target> DOCS-PNM-MIB::docsPnmCmtsUsOfdmaRxPwrEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.27.1.3.6.1.1.1 snmpget -v2c -c public <target> DOCS-PNM-MIB::docsPnmCmtsUsOfdmaRxPwrEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4491.2.1.27.1.3.6.1.1.1 s <value>
Start monitoring DOCSIS 3.1 cable modem/CMTS (Proactive Network Maintenance, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-PNM-MIB::docsPnmCmtsUsOfdmaRxPwrEnable OID value, configure state conditions and alerts, and monitor any DOCSIS 3.1 cable modem/CMTS (Proactive Network Maintenance, vendor-neutral CableLabs standard) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4491 | cableLabs | CLAB-DEF-MIB |
| 1.3.6.1.4.1.4491.2 | clabProject | CLAB-DEF-MIB |
| 1.3.6.1.4.1.4491.2.1 | clabProjDocsis | CLAB-DEF-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4491.2.1.27 | docsPnmMIB | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1 | docsPnmMibObjects | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.3 | docsPnmCmtsObjects | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.3.6 | docsPnmCmtsUsOfdmaRxPwrTable | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.3.6.1 | docsPnmCmtsUsOfdmaRxPwrEntry | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.3.6.1.1 | docsPnmCmtsUsOfdmaRxPwrEnable | DOCS-PNM-MIB |