DOCS-PNM-MIB :: docsPnmCmtsOptRespNcpFieldCt

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DOCS-PNM-MIB › docsPnmCmtsOptRespNcpFieldCt

docsPnmCmtsOptRespNcpFieldCt

Module: DOCS-PNM-MIB

OID (symbolic): DOCS-PNM-MIB::docsPnmCmtsOptRespNcpFieldCt

OID (numeric): 1.3.6.1.4.1.4491.2.1.27.1.3.9.4.1.10

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: This attribute records the number of NCP fields that were examined by the CM during the test interval.

What is docsPnmCmtsOptRespNcpFieldCt?

The number of NCP (Next Codeword Pointer) fields the CM examined during the OPT test interval. Forms the denominator alongside docsPnmCmtsOptRespNcpCrcFailCt for computing the NCP CRC failure rate during the test.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.27.1.3.9.4.1.10
snmpwalk -v2c -c public <target> DOCS-PNM-MIB::docsPnmCmtsOptRespNcpFieldCt

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.27.1.3.9.4.1.10.1
snmpget -v2c -c public <target> DOCS-PNM-MIB::docsPnmCmtsOptRespNcpFieldCt.1

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> docsPnmCmtsOptRespNcpFieldCt.1

Start monitoring DOCSIS 3.1 cable modem/CMTS (Proactive Network Maintenance, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-PNM-MIB::docsPnmCmtsOptRespNcpFieldCt OID value, configure state conditions and alerts, and monitor any DOCSIS 3.1 cable modem/CMTS (Proactive Network Maintenance, vendor-neutral CableLabs standard) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.27docsPnmMIBDOCS-PNM-MIB
1.3.6.1.4.1.4491.2.1.27.1docsPnmMibObjectsDOCS-PNM-MIB
1.3.6.1.4.1.4491.2.1.27.1.3docsPnmCmtsObjectsDOCS-PNM-MIB
1.3.6.1.4.1.4491.2.1.27.1.3.9docsPnmCmtsOptObjectsDOCS-PNM-MIB
1.3.6.1.4.1.4491.2.1.27.1.3.9.4docsPnmCmtsOptRespTableDOCS-PNM-MIB
1.3.6.1.4.1.4491.2.1.27.1.3.9.4.1docsPnmCmtsOptRespEntryDOCS-PNM-MIB
1.3.6.1.4.1.4491.2.1.27.1.3.9.4.1.10docsPnmCmtsOptRespNcpFieldCtDOCS-PNM-MIB