All MIBs › DOCS-PNM-MIB › docsPnmCmDsOfdmFecFileEnable
docsPnmCmDsOfdmFecFileEnable
Module: DOCS-PNM-MIB
OID (symbolic): DOCS-PNM-MIB::docsPnmCmDsOfdmFecFileEnable
OID (numeric): 1.3.6.1.4.1.4491.2.1.27.1.2.7.1.2
Node type: OBJECT-TYPE
Type: TruthValue
Access: read-write
Description: When this attribute is set to 'true' the CM must begin the SummaryType codeword error summary test. While the test is in progress, the CM must return a MeasStatus value of 'busy'. When the measurement is complete the CM must set the MeasEnable attribute to 'false'. If this attribute is set to 'false' during a test, the CM must stop the test.
Interaction with other table rows:
- This object is subject to the rules specified by the 'docsPnmCmCtlStatus' object. Therefore this object returns 'inconsistentValue' if set to 'true' while the value of 'docsPnmCmCtlStatus' is any value other than 'ready'.
- This object returns 'inconsistentValue' if set to 'true' while the CM is in DOCSIS Light Sleep (DLS) mode or the CM is in battery-backup mode.
- A default value for 'docsPnmCmDsOfdmFecFileName' is defined; thus, this object may be set to 'true' without explicitly setting this value.
- Setting this object to a value of 'true' will change the value of the 'docsPnmCmDsOfdmFecMeasStatus' to 'busy'.
The CM must return the value of 'true' if it is actively taking a measurement; otherwise it must return 'false'.
What is docsPnmCmDsOfdmFecFileEnable?
Setting this 'true' starts the codeword-error summary test of the type/duration set by docsPnmCmDsOfdmFecSumType; the CM clears it back to 'false' when the test completes or if set false mid-test. Used to capture a time series of total/corrected/uncorrectable codeword counts for spotting periodic or transient downstream errors.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.27.1.2.7.1.2 snmpwalk -v2c -c public <target> DOCS-PNM-MIB::docsPnmCmDsOfdmFecFileEnable
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.27.1.2.7.1.2.1 snmpget -v2c -c public <target> DOCS-PNM-MIB::docsPnmCmDsOfdmFecFileEnable.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.4491.2.1.27.1.2.7.1.2.1 s <value>
Start monitoring DOCSIS 3.1 cable modem/CMTS (Proactive Network Maintenance, vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-PNM-MIB::docsPnmCmDsOfdmFecFileEnable OID value, configure state conditions and alerts, and monitor any DOCSIS 3.1 cable modem/CMTS (Proactive Network Maintenance, vendor-neutral CableLabs standard) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.4491 | cableLabs | CLAB-DEF-MIB |
| 1.3.6.1.4.1.4491.2 | clabProject | CLAB-DEF-MIB |
| 1.3.6.1.4.1.4491.2.1 | clabProjDocsis | CLAB-DEF-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.4491.2.1.27 | docsPnmMIB | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1 | docsPnmMibObjects | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.2 | docsPnmCmObjects | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.2.7 | docsPnmCmDsOfdmFecTable | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.2.7.1 | docsPnmCmDsOfdmFecEntry | DOCS-PNM-MIB |
| 1.3.6.1.4.1.4491.2.1.27.1.2.7.1.2 | docsPnmCmDsOfdmFecFileEnable | DOCS-PNM-MIB |