DOCS-EQAM-MIB :: docsEqamSessionLogInputContinuityErrors

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DOCS-EQAM-MIB › docsEqamSessionLogInputContinuityErrors

docsEqamSessionLogInputContinuityErrors

Module: DOCS-EQAM-MIB

OID (symbolic): DOCS-EQAM-MIB::docsEqamSessionLogInputContinuityErrors

OID (numeric): 1.3.6.1.4.1.4491.2.1.24.1.18.1.5

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This attribute indicates the total number of continuity counter errors for the session. See SCTE154-4 mpegInputStatsContinuityErrors for details of the count definition.

What is docsEqamSessionLogInputContinuityErrors?

Reports the total number of MPEG continuity-counter errors recorded for this terminated session, an indicator of packet loss on the input feed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.24.1.18.1.5
snmpwalk -v2c -c public <target> DOCS-EQAM-MIB::docsEqamSessionLogInputContinuityErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4491.2.1.24.1.18.1.5.1
snmpget -v2c -c public <target> DOCS-EQAM-MIB::docsEqamSessionLogInputContinuityErrors.1

Start monitoring EQAM (Edge QAM) headend/edge device (vendor-neutral CableLabs standard) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DOCS-EQAM-MIB::docsEqamSessionLogInputContinuityErrors OID value, configure state conditions and alerts, and monitor any EQAM (Edge QAM) headend/edge device (vendor-neutral CableLabs standard) from a single console.

How to Use in IPNetwork Monitor

Select an EQAM (Edge QAM) headend/edge device (vendor-neutral CableLabs standard) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type docsEqamSessionLogInputContinuityErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This attribute indicates the total number of continuity counter errors for the session. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4491cableLabsCLAB-DEF-MIB
1.3.6.1.4.1.4491.2clabProjectCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1clabProjDocsisCLAB-DEF-MIB
1.3.6.1.4.1.4491.2.1.24ccapMibCCAP-MIB
1.3.6.1.4.1.4491.2.1.24.1ccapObjectsCCAP-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4491.2.1.24.1.18docsEqamSessionLogTableDOCS-EQAM-MIB
1.3.6.1.4.1.4491.2.1.24.1.18.1docsEqamSessionLogEntryDOCS-EQAM-MIB
1.3.6.1.4.1.4491.2.1.24.1.18.1.5docsEqamSessionLogInputContinuityErrorsDOCS-EQAM-MIB