DELLRCSG2-TRAP-MIB :: dellrcsg2PduOutletOnSenseFailTrap

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELLRCSG2-TRAP-MIB › dellrcsg2PduOutletOnSenseFailTrap

dellrcsg2PduOutletOnSenseFailTrap

Module: DELLRCSG2-TRAP-MIB

OID (symbolic): DELLRCSG2-TRAP-MIB::dellrcsg2PduOutletOnSenseFailTrap

OID (numeric): 1.3.6.1.4.1.10418.18.21.0.55

Node type: NOTIFICATION-TYPE

Description: A power device attached to the RCS has detected an on sense failure for a outlet. An on sense failure occurs when a outlet should be in the on state but is actually in the off state. The port number on the RCS that the power device is attached to is contained in dellrcsg2TrapObjectPduDevicePort. The outlet number that has the failure is contained in dellrcsg2TrapObjectPduOutlet. The name of the server connected to the power device outlet is contained in dellrcsg2TrapObjectTargetDeviceName. The number of the power device that is connected to a port of the RCS is contained in dellrcsg2TrapObjectPduDeviceNumber.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' DELLRCSG2-TRAP-MIB::dellrcsg2PduOutletOnSenseFailTrap
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.10418.18.21.0.55

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:61659->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (300667099) 34 days, 19:11:10.99
  SNMPv2-MIB::snmpTrapOID.0 = OID: DELLRCSG2-TRAP-MIB::dellrcsg2PduOutletOnSenseFailTrap

Start monitoring Dell chassis management controllers with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELLRCSG2-TRAP-MIB::dellrcsg2PduOutletOnSenseFailTrap OID value, configure state conditions and alerts, and monitor any Dell chassis management controllers from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.10418dellDELLRCSG2-TRAP-MIB
1.3.6.1.4.1.10418.18dellrcsg2DELLRCSG2-TRAP-MIB
1.3.6.1.4.1.10418.18.21dellrcsg2ProductsDELLRCSG2-TRAP-MIB
1.3.6.1.4.1.10418.18.21.0.55dellrcsg2PduOutletOnSenseFailTrapDELLRCSG2-TRAP-MIB