All MIBs › DELLRAC-MIB › drsAlertCurrentStatus
drsAlertCurrentStatus
Module: DELLRAC-MIB
OID (symbolic): DELLRAC-MIB::drsAlertCurrentStatus
OID (numeric): 1.3.6.1.4.1.674.10892.2.5000.10.4
Node type: OBJECT-TYPE
Type: DellStatus
Access: read-only
Description: 5000.0010.0004 Current status of object causing the alert.
What is drsAlertCurrentStatus?
A read-only DellStatus trap variable giving the current status of whatever object triggered the alert (e.g. critical(5)). Comparing it against drsAlertPreviousStatus tells the admin whether a condition is worsening or recovering.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.5000.10.4 snmpwalk -v2c -c public <target> DELLRAC-MIB::drsAlertCurrentStatus
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.2.5000.10.4.1 snmpget -v2c -c public <target> DELLRAC-MIB::drsAlertCurrentStatus.1
Start monitoring Dell PowerEdge server (DRAC/iDRAC out-of-band controller) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELLRAC-MIB::drsAlertCurrentStatus OID value, configure state conditions and alerts, and monitor any Dell PowerEdge server (DRAC/iDRAC out-of-band controller) from a single console.
OID Breakdown
Upper-level ancestors (11 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.674 | dell | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10892 | server3 | DCS3FRU-MIB |
| 1.3.6.1.4.1.674.10892.2 | drsOutOfBandGroup | DCS3RMT-MIB |
| 1.3.6.1.4.1.674.10892.2.5000 | drsAlertGroup | DELL-RAC-MIB |
| 1.3.6.1.4.1.674.10892.2.5000.10 | drsAlertVariables | DELL-RAC-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.674.10892.2.5000.10.4 | drsAlertCurrentStatus | DELLRAC-MIB |