DELL-MM-MIB :: dmmPowerWattsMinUsage

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DELL-MM-MIB › dmmPowerWattsMinUsage

dmmPowerWattsMinUsage

Module: DELL-MM-MIB

OID (symbolic): DELL-MM-MIB::dmmPowerWattsMinUsage

OID (numeric): 1.3.6.1.4.1.674.10892.6.4.1.1.7

Node type: OBJECT-TYPE

Type: DellPowerReading

Access: read-only

Description: This attribute defines the chassis mimimum power usage (in Watts) since last reset.

What is dmmPowerWattsMinUsage?

This value reports the chassis's minimum power usage in Watts since the last reset. Admins use it, alongside the peak reading, to understand the full operating range of chassis power draw for capacity and efficiency planning.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10892.6.4.1.1.7
snmpwalk -v2c -c public <target> DELL-MM-MIB::dmmPowerWattsMinUsage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10892.6.4.1.1.7.1
snmpget -v2c -c public <target> DELL-MM-MIB::dmmPowerWattsMinUsage.1

Start monitoring Dell PowerEdge blade server chassis (Modular Management/M1000e) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DELL-MM-MIB::dmmPowerWattsMinUsage OID value, configure state conditions and alerts, and monitor any Dell PowerEdge blade server chassis (Modular Management/M1000e) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10892server3DCS3FRU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10892.6dmmOutOfBandGroupDELL-MM-MIB
1.3.6.1.4.1.674.10892.6.4dmmChassisPowerGroupDELL-MM-MIB
1.3.6.1.4.1.674.10892.6.4.1dmmPowerTableDELL-MM-MIB
1.3.6.1.4.1.674.10892.6.4.1.1dmmPowerTableEntryDELL-MM-MIB
1.3.6.1.4.1.674.10892.6.4.1.1.7dmmPowerWattsMinUsageDELL-MM-MIB