DDN-WOS-MIB :: wosStatsReadCount

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsDDN-WOS-MIBwosStatsReadCount

wosStatsReadCount

Module: DDN-WOS-MIB

OID (symbolic): DDN-WOS-MIB::wosStatsReadCount

OID (numeric): 1.3.6.1.4.1.6894.4.1.1.2.9

Node type: OBJECT-TYPE

Type: Counter64

Access: read-only

Description: Total number of read transactions since the last cluster restart.

What is wosStatsReadCount?

Cumulative count of read transactions on the cluster since its last restart. Because it's a Counter64 that resets on restart, an admin can also use an unexpected drop in this value as a signal that the cluster (or reporting node) recently rebooted.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.6894.4.1.1.2.9
snmpwalk -v2c -c public <target> DDN-WOS-MIB::wosStatsReadCount

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.6894.4.1.1.2.9.1
snmpget -v2c -c public <target> DDN-WOS-MIB::wosStatsReadCount.1

Start monitoring DataDirect Networks (DDN) Web Object Scaler (WOS) storage cluster with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DDN-WOS-MIB::wosStatsReadCount OID value, configure state conditions and alerts, and monitor any DataDirect Networks (DDN) Web Object Scaler (WOS) storage cluster from a single console.

How to Use in IPNetwork Monitor

Select a DataDirect Networks (DDN) Web Object Scaler (WOS) storage cluster as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type wosStatsReadCount into the Find box to locate it in the OID tree, then select it and click OK. It reports the total number of read transactions since the last cluster restart. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter64-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.6894datadirectDDN-WOS-MIB
1.3.6.1.4.1.6894.4wosDDN-WOS-MIB
1.3.6.1.4.1.6894.4.1wosMIBDDN-WOS-MIB
1.3.6.1.4.1.6894.4.1.1wosObjectsDDN-WOS-MIB
1.3.6.1.4.1.6894.4.1.1.2wosStatsInfoDDN-WOS-MIB
1.3.6.1.4.1.6894.4.1.1.2.9wosStatsReadCountDDN-WOS-MIB