DC-ISIS-MIB :: isisCircLevelLSPThrottle

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DC-ISIS-MIB › isisCircLevelLSPThrottle

isisCircLevelLSPThrottle

Module: DC-ISIS-MIB

OID (symbolic): DC-ISIS-MIB::isisCircLevelLSPThrottle

OID (numeric): 1.2.826.0.1.1578918.5.63.1.1.4.1.1.11

Node type: OBJECT-TYPE

Type: Unsigned16TC

Access: read-create

Description: Minimal interval of time, in milliseconds, between transmissions of LSPs on an interface at this level.

What is isisCircLevelLSPThrottle?

Sets the minimum interval, in milliseconds (default 30), between consecutive LSP transmissions on this circuit at this level, pacing back-to-back LSP floods to avoid overwhelming the link or neighbor. An admin raises this on a low-bandwidth or high-latency circuit to throttle LSP flooding rate, distinct from isisCircLevelMinLSPRetransInt which paces retransmission of the same LSP rather than the rate of distinct LSPs.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.2member_bodyIEEE802dot11-MIB
1.2.826gbMETASWITCH-MIB
1.2.826.0gbNationalMETASWITCH-MIB
1.2.826.0.1gbNatCompanyMETASWITCH-MIB
1.2.826.0.1.1578918dataConnectionMETASWITCH-MIB
Numeric OIDNameModule
1.2.826.0.1.1578918.5.63.1dcIsisMibDC-ISIS-MIB
1.2.826.0.1.1578918.5.63.1.1isisObjectsDC-ISIS-MIB
1.2.826.0.1.1578918.5.63.1.1.4isisCircLevelValuesDC-ISIS-MIB
1.2.826.0.1.1578918.5.63.1.1.4.1isisCircLevelTableDC-ISIS-MIB
1.2.826.0.1.1578918.5.63.1.1.4.1.1isisCircLevelEntryDC-ISIS-MIB
1.2.826.0.1.1578918.5.63.1.1.4.1.1.11isisCircLevelLSPThrottleDC-ISIS-MIB