DATA-DOMAIN-MIB :: nvramBatteryCharge

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › DATA-DOMAIN-MIB › nvramBatteryCharge

nvramBatteryCharge

Module: DATA-DOMAIN-MIB

OID (symbolic): DATA-DOMAIN-MIB::nvramBatteryCharge

OID (numeric): 1.3.6.1.4.1.19746.1.2.3.1.1.3

Node type: OBJECT-TYPE

Type: Percentage

Access: read-only

Description: NVRAM Battery change percentage

What is nvramBatteryCharge?

The current charge level of the NVRAM backup battery as a percentage; a low value shortly after a power event is normal, but one that never recovers points to a battery needing replacement.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.19746.1.2.3.1.1.3
snmpwalk -v2c -c public <target> DATA-DOMAIN-MIB::nvramBatteryCharge

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.19746.1.2.3.1.1.3.1
snmpget -v2c -c public <target> DATA-DOMAIN-MIB::nvramBatteryCharge.1

Start monitoring Data Domain deduplication storage appliance (dd200-dd590g) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the DATA-DOMAIN-MIB::nvramBatteryCharge OID value, configure state conditions and alerts, and monitor any Data Domain deduplication storage appliance (dd200-dd590g) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.19746dataDomainMibDATA-DOMAIN-MIB
1.3.6.1.4.1.19746.1dataDomainMibObjectsDATA-DOMAIN-MIB
1.3.6.1.4.1.19746.1.2nvramDATA-DOMAIN-MIB
1.3.6.1.4.1.19746.1.2.3nvramBatteriesDATA-DOMAIN-MIB
1.3.6.1.4.1.19746.1.2.3.1nvramBatteryTableDATA-DOMAIN-MIB
1.3.6.1.4.1.19746.1.2.3.1.1nvramBatteryEntryDATA-DOMAIN-MIB
1.3.6.1.4.1.19746.1.2.3.1.1.3nvramBatteryChargeDATA-DOMAIN-MIB