CXMCPRT-MIB :: cxMcPrtBopLimitOutFlowCtrl

MIB Reference — IPNetwork Monitor · Updated October 05, 2026

All MIBs › CXMCPRT-MIB › cxMcPrtBopLimitOutFlowCtrl

cxMcPrtBopLimitOutFlowCtrl

Module: CXMCPRT-MIB

OID (symbolic): CXMCPRT-MIB::cxMcPrtBopLimitOutFlowCtrl

OID (numeric): 1.3.6.1.4.1.495.2.1.1.1.5.1.1.22

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The limit before output flow control of the synchronous port.

Range of Values: HC600: 1-100, MC600: 0-4000

Default Value: HC600: 15, MC600: 3

What is cxMcPrtBopLimitOutFlowCtrl?

Sets the buffer threshold that triggers output flow control on the BOP port; range/default vary by chassis (HC600: 1-100, default 15; MC600: 0-4000, default 3), used to tune how soon the port throttles its own transmission.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.495.2.1.1.1.5.1.1.22
snmpwalk -v2c -c public <target> CXMCPRT-MIB::cxMcPrtBopLimitOutFlowCtrl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.495.2.1.1.1.5.1.1.22.1
snmpget -v2c -c public <target> CXMCPRT-MIB::cxMcPrtBopLimitOutFlowCtrl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.495.2.1.1.1.5.1.1.22.1 i <value>

Start monitoring Legacy HC600 chassis equipment (multi-channel serial console ports) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the CXMCPRT-MIB::cxMcPrtBopLimitOutFlowCtrl OID value, configure state conditions and alerts, and monitor any Legacy HC600 chassis equipment (multi-channel serial console ports) from a single console.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.495memotecMEMOTEC-SMI
1.3.6.1.4.1.495.2memotecProductsMEMOTEC-SMI
1.3.6.1.4.1.495.2.1cxProductMEMOTEC-SMI
1.3.6.1.4.1.495.2.1.1cxMc600CXProduct-SMI
Numeric OIDNameModule
1.3.6.1.4.1.495.2.1.1.1cxMcPrtCXMCPRT-MIB
1.3.6.1.4.1.495.2.1.1.1.5cxMcPrtDriverCXMCPRT-MIB
1.3.6.1.4.1.495.2.1.1.1.5.1cxMcPrtBopTableCXMCPRT-MIB
1.3.6.1.4.1.495.2.1.1.1.5.1.1cxMcPrtBopEntryCXMCPRT-MIB
1.3.6.1.4.1.495.2.1.1.1.5.1.1.22cxMcPrtBopLimitOutFlowCtrlCXMCPRT-MIB